These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 16874982)

  • 1. Use of water-drinking tonography in mass screening for glaucoma.
    Suzuki Y; Takeuchi T; Kitazawa Y
    Am J Ophthalmol; 1966 May; 61(5 Pt 1):847-53. PubMed ID: 16874982
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The importance and accuracy of the water drinking test and tonography.
    Vucicevic ZM; Scheie HG; Berry A; Yaros M; Frauenhoffer C
    Ann Ophthalmol; 1975 Jan; 7(1):39-45. PubMed ID: 1111415
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Scarborough glaucoma survey.
    Shenken E
    Can Med Assoc J; 1966 Sep; 95(12):595-602. PubMed ID: 5912178
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Glaucoma screening with Schiotz' tonometer and tension-indicator of applanation type.
    Jensen JB
    Acta Ophthalmol (Copenh); 1968; 46(4):638-42. PubMed ID: 5755687
    [No Abstract]   [Full Text] [Related]  

  • 5. Evaluation of water drinking test and tonography in detection of glaucoma.
    Sivaramasubramanian P
    J All India Ophthalmol Soc; 1970 Dec; 18(4):162-6. PubMed ID: 5524567
    [No Abstract]   [Full Text] [Related]  

  • 6. [The diagnostic efficiency of tonography].
    Dutescu M
    Fortschr Med; 1978 Mar; 96(11):593-6. PubMed ID: 631699
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Tonography test according to Leydhecker. Clinical comparison by tonography according to Grant (author's transl)].
    Dausch D; Wachholz EA; Honegger H
    Klin Monbl Augenheilkd; 1975 Jan; 166(1):59-64. PubMed ID: 1117645
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Methods of mathematical differentiation in tonography.
    Dutescu M
    Albrecht Von Graefes Arch Klin Exp Ophthalmol; 1975 Jun; 195(3):175-86. PubMed ID: 1080965
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reproducibility of intraocular pressure and outflow facility measured by pneumatic tonography and Schiotz tonography.
    Wheeler NC; Lee DA; Cheng Q; Ross WF; Hadjiaghai L
    J Ocul Pharmacol Ther; 1998 Feb; 14(1):5-13. PubMed ID: 9493779
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [A clinical study on water-drinking tonography. (3). Water-drinking tonography in steroid-induced ocular hypertension].
    Kitazawa Y
    Nippon Ganka Gakkai Zasshi; 1966 Mar; 70(3):292-9. PubMed ID: 6005678
    [No Abstract]   [Full Text] [Related]  

  • 11. Glaucoma screening in primary care: the role of noncontact tonometry.
    Ralston ME; Choplin NT; Hollenbach KA; Applegate BJ; Henn TW
    J Fam Pract; 1992 Jan; 34(1):73-7. PubMed ID: 1728657
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Water drinking and outflow facility.
    Kronfeld PC
    Invest Ophthalmol; 1975 Jan; 14(1):49-52. PubMed ID: 1110138
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ocular pulse amplitude measurement using pascal dynamic contour tonometer in glaucoma patients.
    Katsimpris JM; Theoulakis PE; Papadopoulos GE; Katsimpris A; Lepidas J; Petropoulos IK
    Klin Monbl Augenheilkd; 2014 Apr; 231(4):363-7. PubMed ID: 24771168
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Ocular pulse amplitude: a new biometrical parameter for the diagnose of glaucoma?].
    Romppainen T; Kniestedt C; Bachmann LM; Stürmer J
    Ophthalmologe; 2007 Mar; 104(3):230-5. PubMed ID: 17323044
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of intraocular pressure measurement between rebound, non-contact and Goldmann applanation tonometry in treated glaucoma patients.
    Vincent SJ; Vincent RA; Shields D; Lee GA
    Clin Exp Ophthalmol; 2012; 40(4):e163-70. PubMed ID: 21883774
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Positive ibopamine provocative test in normal-tension glaucoma suspects].
    Kniestedt C; Romppainen T; Gloor BP; Stürmer J
    Klin Monbl Augenheilkd; 2007 Apr; 224(4):255-9. PubMed ID: 17458787
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Leydhecker tonography and Ulrich ocular pressure tonometry in probands with healthy eyes and glaucoma patients].
    Mattern A; Stodtmeister R; Pillunat LE; Abel T
    Fortschr Ophthalmol; 1989; 86(4):411-5. PubMed ID: 2793019
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Correlation between Central Corneal Thickness and Intraocular Pressure Measured by Goldmann Applanation Tonometry or Pascal Dynamic Contour Tonometry.
    Katsimpris JM; Theoulakis PE; Vasilopoulos K; Skourtis G; Papadopoulos GE; Petropoulos IK
    Klin Monbl Augenheilkd; 2015 Apr; 232(4):414-8. PubMed ID: 25902089
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Tonometry screening on the medical service.
    Robertson D
    Arch Intern Med; 1977 Apr; 137(4):443-5. PubMed ID: 849083
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Intraocular pressure difference in Goldmann applanation tonometry versus a transpalpebral tonometer TGDc-01"PRA" in glaucoma patients].
    Schlote T; Landenberger H
    Klin Monbl Augenheilkd; 2005 Feb; 222(2):123-31. PubMed ID: 15719316
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.