164 related articles for article (PubMed ID: 16877022)
1. Prediction of lubrication regimes in two-piece metacarpophalangeal prostheses.
Joyce TJ
Med Eng Phys; 2007 Jan; 29(1):87-92. PubMed ID: 16877022
[TBL] [Abstract][Full Text] [Related]
2. Calculation of theoretical lubrication regimes in two-piece first metatarsophalangeal prostheses.
Joyce TJ
Biomed Mater Eng; 2008; 18(1):45-51. PubMed ID: 18198406
[TBL] [Abstract][Full Text] [Related]
3. [Tribologic investigation of a metacarpophalangeal prosthesis].
Rieker CB; Joyce T; Unsworth A; Hagena FW; Meuli C
Orthopade; 2003 Sep; 32(9):784-8. PubMed ID: 14508643
[TBL] [Abstract][Full Text] [Related]
4. Appropriate radial clearance of ceramic-on-ceramic total hip prostheses to realize squeeze-film lubrication.
Mabuchi K; Sakai R; Ota M; Ujihira M
Clin Biomech (Bristol, Avon); 2004 May; 19(4):362-9. PubMed ID: 15109756
[TBL] [Abstract][Full Text] [Related]
5. Contact mechanics and elastohydrodynamic lubrication in a novel metal-on-metal hip implant with an aspherical bearing surface.
Meng Q; Gao L; Liu F; Yang P; Fisher J; Jin Z
J Biomech; 2010 Mar; 43(5):849-57. PubMed ID: 20003978
[TBL] [Abstract][Full Text] [Related]
6. Changes in the contact area during the bedding-in wear of different sizes of metal on metal hip prostheses.
Hu XQ; Isaac GH; Fisher J
Biomed Mater Eng; 2004; 14(2):145-9. PubMed ID: 15156105
[TBL] [Abstract][Full Text] [Related]
7. Effect of bearing geometry and structure support on transient elastohydrodynamic lubrication of metal-on-metal hip implants.
Liu F; Jin Z; Roberts P; Grigoris P
J Biomech; 2007; 40(6):1340-9. PubMed ID: 16824529
[TBL] [Abstract][Full Text] [Related]
8. Prediction of lubrication regimes in wrist implants with spherical bearing surfaces.
Pylios T; Shepherd DE
J Biomech; 2004 Mar; 37(3):405-11. PubMed ID: 14757461
[TBL] [Abstract][Full Text] [Related]
9. Transient elastohydrodynamic lubrication analysis of metal-on-metal hip implant under simulated walking conditions.
Liu F; Jin ZM; Hirt F; Rieker C; Roberts P; Grigoris P
J Biomech; 2006; 39(5):905-14. PubMed ID: 16199048
[TBL] [Abstract][Full Text] [Related]
10. [FE-analysis of surface stresses for the tribological system in total hip prostheses].
Behrens BA; Helms G; Pösse O; Nolte I; Meyer-Lindenberg A; Rittmann P; Windhagen H; Pressel T
Biomed Tech (Berl); 2006 Dec; 51(5-6):367-70. PubMed ID: 17155874
[TBL] [Abstract][Full Text] [Related]
11. A test procedure for artificial finger joints.
Joyce TJ; Unsworth A
Proc Inst Mech Eng H; 2002; 216(2):105-10. PubMed ID: 12022417
[TBL] [Abstract][Full Text] [Related]
12. Effect of 3D physiological loading and motion on elastohydrodynamic lubrication of metal-on-metal total hip replacements.
Gao L; Wang F; Yang P; Jin Z
Med Eng Phys; 2009 Jul; 31(6):720-9. PubMed ID: 19269879
[TBL] [Abstract][Full Text] [Related]
13. Lubrication regimes in lumbar total disc arthroplasty.
Shaheen A; Shepherd DE
Proc Inst Mech Eng H; 2007 Aug; 221(6):621-7. PubMed ID: 17937201
[TBL] [Abstract][Full Text] [Related]
14. Lubrication and friction prediction in metal-on-metal hip implants.
Wang FC; Brockett C; Williams S; Udofia I; Fisher J; Jin ZM
Phys Med Biol; 2008 Mar; 53(5):1277-93. PubMed ID: 18296762
[TBL] [Abstract][Full Text] [Related]
15. [Bionic surface design in metal on metal bearings for total hip arthroplasty--optimization of tribological characteristics].
Böhling U; Scholz J; Thomas W; Grundei H
Biomed Tech (Berl); 2005 Apr; 50(4):119-23. PubMed ID: 15884709
[TBL] [Abstract][Full Text] [Related]
16. Polyurethane unicondylar knee prostheses: simulator wear tests and lubrication studies.
Scholes SC; Unsworth A; Jones E
Phys Med Biol; 2007 Jan; 52(1):197-212. PubMed ID: 17183136
[TBL] [Abstract][Full Text] [Related]
17. Effect of swing phase load on metal-on-metal hip lubrication, friction and wear.
Williams S; Jalali-Vahid D; Brockett C; Jin Z; Stone MH; Ingham E; Fisher J
J Biomech; 2006; 39(12):2274-81. PubMed ID: 16143337
[TBL] [Abstract][Full Text] [Related]
18. [Arthroplasty of the metacarpophalangeal joint using pyrocarbonate implants].
Beckenbaugh RD
Orthopade; 2003 Sep; 32(9):794-7. PubMed ID: 14508645
[TBL] [Abstract][Full Text] [Related]
19. Contact stresses in lumbar total disc arthroplasty.
Wenzel SA; Shepherd DE
Biomed Mater Eng; 2007; 17(3):169-73. PubMed ID: 17502693
[TBL] [Abstract][Full Text] [Related]
20. Currently available metacarpophalangeal prostheses: their designs and prospective considerations.
Joyce TJ
Expert Rev Med Devices; 2004 Nov; 1(2):193-204. PubMed ID: 16293040
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]