  • 1. Dialyzer clearances and mass transfer-area coefficients for small solutes at low dialysate flow rates.
    Leypoldt JK; Kamerath CD; Gilson JF; Friederichs G
    ASAIO J; 2006; 52(4):404-9. PubMed ID: 16883120
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Increases in mass transfer-area coefficients and urea Kt/V with increasing dialysate flow rate are greater for high-flux dialyzers.
    Leypoldt JK; Cheung AK
    Am J Kidney Dis; 2001 Sep; 38(3):575-9. PubMed ID: 11532691
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Increasing dialysate flow rate increases dialyzer urea mass transfer-area coefficients during clinical use.
    Ouseph R; Ward RA
    Am J Kidney Dis; 2001 Feb; 37(2):316-20. PubMed ID: 11157372
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Flow distribution analysis by helical scanning in polysulfone hemodialyzers: effects of fiber structure and design on flow patterns and solute clearances.
    Ronco C; Levin N; Brendolan A; Nalesso F; Cruz D; Ocampo C; Kuang D; Bonello M; De Cal M; Corradi V; Ricci Z
    Hemodial Int; 2006 Oct; 10(4):380-8. PubMed ID: 17014516
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Hollow fiber shape alters solute clearances in high flux hemodialyzers.
    Leypoldt JK; Cheung AK; Chirananthavat T; Gilson JF; Kamerath CD; Deeter RB
    ASAIO J; 2003; 49(1):81-7. PubMed ID: 12558312
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Relationship between effective ionic dialysance and in vivo urea clearance during hemodialysis.
    Lindsay RM; Bene B; Goux N; Heidenheim AP; Landgren C; Sternby J
    Am J Kidney Dis; 2001 Sep; 38(3):565-74. PubMed ID: 11532690
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Middle molecule removal in low-flux polysulfone dialyzers: impact of flows and surface area on whole-body and dialyzer clearances.
    Eloot S; de Vos JY; de Vos F; Hombrouckx R; Verdonck P
    Hemodial Int; 2005 Oct; 9(4):399-408. PubMed ID: 16219061
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Increasing dialysate flow rate increases dialyzer urea clearance and dialysis efficiency: an in vivo study.
    Azar AT
    Saudi J Kidney Dis Transpl; 2009 Nov; 20(6):1023-9. PubMed ID: 19861865
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of hemodialyzer reuse: dissociation between clearances of small and large solutes.
    Leypoldt JK; Cheung AK; Deeter RB
    Am J Kidney Dis; 1998 Aug; 32(2):295-301. PubMed ID: 9708616
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Solute clearance in continuous venovenous hemodialysis. A comparison of cuprophane, polyacrylonitrile, and polysulfone membranes.
    Ifediora OC; Teehan BP; Sigler MH
    ASAIO J; 1992; 38(3):M697-701. PubMed ID: 1457952
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of formaldehyde/bleach reprocessing on in vivo performances of high-efficiency cellulose and high-flux polysulfone dialyzers.
    Murthy BV; Sundaram S; Jaber BL; Perrella C; Meyer KB; Pereira BJ
    J Am Soc Nephrol; 1998 Mar; 9(3):464-72. PubMed ID: 9513910
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effects of a reduced inner diameter of hollow fibers in hemodialyzers.
    Ronco C; Brendolan A; Lupi A; Metry G; Levin NW
    Kidney Int; 2000 Aug; 58(2):809-17. PubMed ID: 10916106
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Impact of blood and dialysate flow and surface on performance of new polysulfone hemodialysis dialyzers.
    Mandolfo S; Malberti F; Imbasciati E; Cogliati P; Gauly A
    Int J Artif Organs; 2003 Feb; 26(2):113-20. PubMed ID: 12653344
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Slow continuous ultrafiltration with bound solute dialysis.
    Patzer JF; Safta SA; Miller RH
    ASAIO J; 2006; 52(1):47-58. PubMed ID: 16436890
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Blood and dialysate flow distributions in hollow-fiber hemodialyzers analyzed by computerized helical scanning technique.
    Ronco C; Brendolan A; Crepaldi C; Rodighiero M; Scabardi M
    J Am Soc Nephrol; 2002 Jan; 13 Suppl 1():S53-61. PubMed ID: 11792763
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of dialyzer jacket structure and hollow-fiber dialysis membranes to achieve high dialysis performance.
    Hirano A; Yamamoto K; Matsuda M; Ogawa T; Yakushiji T; Miyasaka T; Sakai K
    Ther Apher Dial; 2011 Feb; 15(1):66-74. PubMed ID: 21272255
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Technical characterization of dialysis fluid flow of newly developed dialyzers using mass transfer correlation equations.
    Kunikata S; Fukuda M; Yamamoto K; Yagi Y; Matsuda M; Sakai K
    ASAIO J; 2009; 55(3):231-5. PubMed ID: 19357496
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hemodiafiltration--a new treatment option for hyperphosphatemia in hemodialysis patients.
    Zehnder C; Gutzwiller JP; Renggli K
    Clin Nephrol; 1999 Sep; 52(3):152-9. PubMed ID: 10499310
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hemodialyzer mass transfer-area coefficients for urea increase at high dialysate flow rates. The Hemodialysis (HEMO) Study.
    Leypoldt JK; Cheung AK; Agodoa LY; Daugirdas JT; Greene T; Keshaviah PR
    Kidney Int; 1997 Jun; 51(6):2013-7. PubMed ID: 9186896
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Increasing the clearance of protein-bound solutes by addition of a sorbent to the dialysate.
    Meyer TW; Peattie JW; Miller JD; Dinh DC; Recht NS; Walther JL; Hostetter TH
    J Am Soc Nephrol; 2007 Mar; 18(3):868-74. PubMed ID: 17251385
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 61.