These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 1688333)

  • 1. Corrosion at the interface of cobalt-alloy heads on titanium-alloy stems.
    Collier JP; Surprenant VA; Jensen RE; Mayor MB
    Clin Orthop Relat Res; 1991 Oct; (271):305-12. PubMed ID: 1688333
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An analysis of the head-neck taper interface in retrieved hip prostheses.
    Lieberman JR; Rimnac CM; Garvin KL; Klein RW; Salvati EA
    Clin Orthop Relat Res; 1994 Mar; (300):162-7. PubMed ID: 8131330
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Differences in the fretting corrosion of metal-metal and ceramic-metal modular junctions of total hip replacements.
    Hallab NJ; Messina C; Skipor A; Jacobs JJ
    J Orthop Res; 2004 Mar; 22(2):250-9. PubMed ID: 15013082
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The tradeoffs associated with modular hip prostheses.
    Collier JP; Mayor MB; Williams IR; Surprenant VA; Surprenant HP; Currier BH
    Clin Orthop Relat Res; 1995 Feb; (311):91-101. PubMed ID: 7634596
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Mechanisms of failure of modular prostheses.
    Collier JP; Mayor MB; Jensen RE; Surprenant VA; Surprenant HP; McNamar JL; Belec L
    Clin Orthop Relat Res; 1992 Dec; (285):129-39. PubMed ID: 1446428
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Osteolysis in cemented titanium alloy hip prosthesis.
    Schöll E; Eggli S; Ganz R
    J Arthroplasty; 2000 Aug; 15(5):570-5. PubMed ID: 10959994
    [TBL] [Abstract][Full Text] [Related]  

  • 7. In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling.
    Gilbert JL; Buckley CA; Jacobs JJ
    J Biomed Mater Res; 1993 Dec; 27(12):1533-44. PubMed ID: 8113241
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Corrosion at the interface. A possible solution to cobalt-chrome heads on titanium alloy stems.
    Yerby SA; Taylor JK; Park J; Shackelford JF
    J Arthroplasty; 1996 Feb; 11(2):157-62. PubMed ID: 8648309
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Wear and corrosion of modular interfaces in total hip replacements.
    Cook SD; Barrack RL; Baffes GC; Clemow AJ; Serekian P; Dong N; Kester MA
    Clin Orthop Relat Res; 1994 Jan; (298):80-8. PubMed ID: 8119000
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Corrosion at the stem-sleeve interface of a modular titanium alloy femoral component as a reason for impaired disengagement.
    Fraitzl CR; Moya LE; Castellani L; Wright TM; Buly RL
    J Arthroplasty; 2011 Jan; 26(1):113-9, 119.e1. PubMed ID: 20097041
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Corrosion and wear at the modular interface of uncemented femoral stems.
    Cook SD; Barrack RL; Clemow AJ
    J Bone Joint Surg Br; 1994 Jan; 76(1):68-72. PubMed ID: 8300685
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Investigations on the galvanic corrosion of multialloy total hip prostheses.
    Lucas LC; Buchanan RA; Lemons JE
    J Biomed Mater Res; 1981 Sep; 15(5):731-47. PubMed ID: 12659138
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Human monocyte/macrophage response to cobalt-chromium corrosion products and titanium particles in patients with total joint replacements.
    Lee SH; Brennan FR; Jacobs JJ; Urban RM; Ragasa DR; Glant TT
    J Orthop Res; 1997 Jan; 15(1):40-9. PubMed ID: 9066525
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Crevice corrosion of cemented titanium alloy stems in total hip replacements.
    Willert HG; Brobäck LG; Buchhorn GH; Jensen PH; Köster G; Lang I; Ochsner P; Schenk R
    Clin Orthop Relat Res; 1996 Dec; (333):51-75. PubMed ID: 8981882
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Conus hip prosthesis.
    Wagner H; Wagner M
    Acta Chir Orthop Traumatol Cech; 2001; 68(4):213-21. PubMed ID: 11706545
    [TBL] [Abstract][Full Text] [Related]  

  • 16. New surface-hardened, low-modulus, corrosion-resistant Ti-13Nb-13Zr alloy for total hip arthroplasty.
    Davidson JA; Mishra AK; Kovacs P; Poggie RA
    Biomed Mater Eng; 1994; 4(3):231-43. PubMed ID: 7950871
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cementless total joint arthroplasty prostheses with titanium-alloy articular surfaces. A human retrieval analysis.
    Nasser S; Campbell PA; Kilgus D; Kossovsky N; Amstutz HC
    Clin Orthop Relat Res; 1990 Dec; (261):171-85. PubMed ID: 2245543
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Catastrophic failure of 4 cobalt-alloy Omnifit hip arthroplasty femoral components.
    Lam LO; Stoffel K; Kop A; Swarts E
    Acta Orthop; 2008 Feb; 79(1):18-21. PubMed ID: 18283567
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Corrosion of titanium/cobalt-chromium alloy couples.
    Kummer FJ; Rose RM
    J Bone Joint Surg Am; 1983 Oct; 65(8):1125-6. PubMed ID: 6630255
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fretting corrosion accelerates crevice corrosion of modular hip tapers.
    Brown SA; Flemming CA; Kawalec JS; Placko HE; Vassaux C; Merritt K; Payer JH; Kraay MJ
    J Appl Biomater; 1995; 6(1):19-26. PubMed ID: 7703534
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.