These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 16886696)

  • 1. [Hypoglycaemic coma due to falsely elevated glucose values in a patient with diabetes mellitus and peritoneal dialysis].
    Nienhuis WA; Bruijns RH; Vastenburg G; Wouters RS
    Ned Tijdschr Geneeskd; 2006 Jul; 150(28):1574-6. PubMed ID: 16886696
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Hypoglycemic coma due to falsely elevated glucose values in a patient with diabetes mellitus and peritoneal dialysis].
    Nienhuis WA; Bruijns RH; Vastenburg G; Wouters RS
    Ned Tijdschr Geneeskd; 2006 Oct; 150(41):2285; author reply 2285. PubMed ID: 17076369
    [No Abstract]   [Full Text] [Related]  

  • 3. Hypoglycemic coma in a diabetic patient on peritoneal dialysis due to interference of icodextrin metabolites with capillary blood glucose measurements.
    Disse E; Thivolet C
    Diabetes Care; 2004 Sep; 27(9):2279. PubMed ID: 15333503
    [No Abstract]   [Full Text] [Related]  

  • 4. Significant hypoglycemia secondary to icodextrin peritoneal dialysate in a diabetic patient.
    Kroll HR; Maher TR
    Anesth Analg; 2007 Jun; 104(6):1473-4, table of contents. PubMed ID: 17513644
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A previously undescribed side effect of icodextrin: overestimation of glycemia by glucose analyzer.
    Wens R; Taminne M; Devriendt J; Collart F; Broeders N; Mestrez F; Germanos H; Dratwa M
    Perit Dial Int; 1998; 18(6):603-9. PubMed ID: 9932659
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Masked hypoglycemia in the presence of icodextrin for peritoneal dialysis.
    Khouli MM
    J Emerg Med; 2013 Feb; 44(2):e191-3. PubMed ID: 22579020
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Occult hypoglycemia in a diabetic patient on peritoneal dialysis.
    Charles RA; Goh SY
    Eur J Emerg Med; 2005 Dec; 12(6):322-3. PubMed ID: 16276267
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [False measurement of glucose during dialysis with icodextrin].
    Husøy AM; Knudsen GR; Thierley M; Svarstad E
    Tidsskr Nor Laegeforen; 2006 Sep; 126(17):2268-70. PubMed ID: 16967067
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The danger of using inappropriate point-of-care glucose meters in patients on icodextrin dialysis.
    Perera NJ; Stewart PM; Williams PF; Chua EL; Yue DK; Twigg SM
    Diabet Med; 2011 Oct; 28(10):1272-6. PubMed ID: 21679233
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Icodextrin - still a cause for concern with blood glucose monitoring in continuous ambulatory peritoneal dialysis patients with diabetes.
    Slim S; Griffiths MJ; Gama R
    Ann Clin Biochem; 2007 Mar; 44(Pt 2):196-7. PubMed ID: 17362588
    [No Abstract]   [Full Text] [Related]  

  • 11. Avoidable iatrogenic hypoglycemia in patients on peritoneal dialysis: the risks of nonspecific glucose monitoring devices and drug-device interaction.
    Firanek CA; Jacob DT; Sloand JA
    J Patient Saf; 2014 Dec; 10(4):218-21. PubMed ID: 23860196
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Inaccurate self-monitoring of blood glucose readings in patients on chronic ambulatory peritoneal dialysis with icodextrin.
    Pavlicek V; Garzoni D; Urech P; Brändle M
    Exp Clin Endocrinol Diabetes; 2006 Mar; 114(3):124-6. PubMed ID: 16636978
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Occult hypoglycaemia in patient with chronic kidney failure and chronic ambulatory peritoneal dialysis].
    de Lange S; Fernández Cabrera J; Gomar Vidal S
    Med Intensiva; 2011 Mar; 35(2):133-4. PubMed ID: 21215492
    [No Abstract]   [Full Text] [Related]  

  • 14. Severe cutaneous hypersensitivity to icodextrin in a continuous ambulatory peritoneal dialysis patient.
    Lee SH; Park HC; Sim SR; Chung SJ; Kim KJ; Park WI; Hong SW; Ha SK
    J Nephrol; 2006; 19(5):673-6. PubMed ID: 17136700
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Clinical experience with icodextrin. Multicenter study].
    Guerrero A; Montes R; Martín-Herrera C; Ruiz A; Remón C; Fernández-Ruiz EJ; Pérez-Bañasco V; Benítez M; Martínez-Benavides E; Martínez-González JM; Torán D; Tejuca F; Páez C; del Pino MD
    Nefrologia; 2001; 21(6):574-80. PubMed ID: 11881427
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Icodextrine and insulin resistance in continuous ambulatory peritoneal dialysis patients.
    Canbakan M; Sahin GM
    Ren Fail; 2007; 29(3):289-93. PubMed ID: 17497442
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Icodextrin in peritoneal dialysis therapy].
    Grzegorzewska AE; Antczak-Jedrzejczak D
    Przegl Lek; 1999; 56(12):812-6. PubMed ID: 10789195
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Icodextrin allergy in a peritoneal dialysis patient.
    Fletcher S; Stables GA; Turney JH
    Nephrol Dial Transplant; 1998 Oct; 13(10):2656-8. PubMed ID: 9794582
    [No Abstract]   [Full Text] [Related]  

  • 19. Severe hypoglycemia due to falsely elevated capillary blood glucose levels in a peritoneal dialysis patient using icodextrin: A case report.
    Cho EJ; Lee SH
    Korean J Anesthesiol; 2009 Feb; 56(2):221-224. PubMed ID: 30625727
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Hypoglycemia in diabetics on dialysis with poor glycemic control: hemodialysis versus continuous ambulatory peritoneal dialysis.
    Tzamaloukas AH; Murata GH; Eisenberg B; Murphy G; Avasthi PS
    Int J Artif Organs; 1992 Jul; 15(7):390-2. PubMed ID: 1516987
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.