These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

182 related articles for article (PubMed ID: 1689026)

  • 1. Intermittent ventricular bigeminy as an expression of two-level Wenckebach periodicity in the reentrant pathway of extrasystoles.
    Kinoshita S; Konishi G; Kinoshita Y
    Pacing Clin Electrophysiol; 1990 Jan; 13(1):119-22. PubMed ID: 1689026
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Type A alternating Wenckebach periodicity in the reentrant pathway of interpolated ventricular extrasystoles.
    Kinoshita S; Konishi G; Kawasaki T
    Cardiology; 1988; 75(6):440-3. PubMed ID: 2465823
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Intermittent ventricular parasystolic bigeminy accompanied by reentrant ventricular extrasystoles.
    Izumi K
    J Electrocardiol; 1990 Apr; 23(2):177-83. PubMed ID: 1692870
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Mechanisms of ventricular parasystole.
    Kinoshita S
    Circulation; 1978 Oct; 58(4):715-22. PubMed ID: 80290
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Concealed (proximal) Wenckebach phenomenon with distal 2:1 exit block in the ectopic-ventricular junction.
    Kinoshita S; Fujita K; Kawaguchi H; Kanda K; Tanabe Y
    Chest; 1978 Feb; 73(2):198-201. PubMed ID: 74308
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Type A alternating Wenckebach periodicity in the re-entrant path of ventricular extrasystoles.
    Kinoshita S; Kurokawa S; Ohnishi S; Oyama Y
    J Electrocardiol; 1980; 13(3):285-9. PubMed ID: 6157762
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mechanisms of concealed ventricular bigeminy: the concept of concealed conduction in the reentrant pathway.
    Kinoshita S; Takahashi K; Nakagawa K; Sagawa A; Tanabe Y; Kawasaki T
    J Electrocardiol; 1986 Jan; 19(1):67-75. PubMed ID: 2433379
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Concealed extrasystoles due to Wenckebach conduction delay within the reentry loop.
    Kerin NZ; Levy MN; Goldberg LB; Rubenfire M
    Clin Cardiol; 1979 Jun; 2(3):217-9. PubMed ID: 92383
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Concealed junctional bigeminy inducing pseudo 2:1 AV block.
    Anderson GJ; Greenspan M; Kimbiris D
    J Electrocardiol; 1981; 14(1):91-6. PubMed ID: 6162904
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Mechanism of tachycardia-dependent appearance of ventricular extrasystoles in concealed bigeminy.
    Kinoshita S; Tanabe Y; Satoh T
    J Electrocardiol; 1996 Oct; 29(4):341-5. PubMed ID: 8913910
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Bradycardia- and tachycardia-dependent termination of ventricular bigeminy: mechanism of ventricular extrasystoles with fixed coupling.
    Kinoshita S; Okada F; Konishi G; Kinoshita M; Ogawa S
    Am Heart J; 1995 Mar; 129(3):557-64. PubMed ID: 7532908
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Second degree entrance block with supernormal conduction in intermittent ventricular parasystole.
    Kinoshita S; Nakagawa K; Kato Y; Yasukouchi T
    J Electrocardiol; 1984 Apr; 17(2):199-203. PubMed ID: 6736845
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Differentiation between parasystole and extrasystoles. Influence of vagal stimulation on parasystolic impulse formation.
    Kinoshita S; Okada F; Konishi G; Kinoshita M; Ito Y
    J Electrocardiol; 1994 Apr; 27(2):169-74. PubMed ID: 7515409
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Regular ventricular rate and "reverse bigeminy" in 3:2 Wenckebach periodicity.
    Littmann L; Tenczer J
    J Electrocardiol; 2020; 62():73-78. PubMed ID: 32835983
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Occult ventricular bigeminy. Description of a case with extrasystole variable coupling separated by sinus beats in even or odd numbers].
    Oreto G; Luzza F; Satullo G; Arrigo F
    G Ital Cardiol; 1983 Dec; 13(12):415-20. PubMed ID: 6200379
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Concealed ventricular extrasystoles due to interference and due to exit block.
    Kinoshita S
    Circulation; 1975 Aug; 52(2):230-7. PubMed ID: 50154
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Mechanism of bradycardia-dependent appearance of manifest extrasystoles in concealed bigeminy. A theoretical model derived from the concepts of longitudinal dissociation and multilevel block in the reentrant pathway of extrasystoles.
    Kinoshita S; Konishi G; Okada F
    G Ital Cardiol; 1992 Mar; 22(3):267-72. PubMed ID: 1385244
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Wenckebach-type exit block from an ectopic focus as a cause of variable coupling.
    Mirvis DM; Bandura JP; Brody DA
    J Electrocardiol; 1976; 9(4):365-70. PubMed ID: 62005
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Mechanism of escape, extrasystolic, and parasystolic arrhythmias. Study on an electrical analogue.
    Sideris DA
    J Electrocardiol; 1976; 9(3):227-38. PubMed ID: 59788
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Bigeminal rhythm due to reentrant ventricular extrasystoles coupled to ventricular and A-V junctional escapes: comparison with ventricular parasystole associated with ventricular extrasystoles of bundle branch reentry.
    Izumi K
    Mater Med Pol; 1989; 21(3):213-22. PubMed ID: 2485075
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.