151 related articles for article (PubMed ID: 16895607)
1. Effect of heat and moisture exchanger (HME) positioning on inspiratory gas humidification.
Inui D; Oto J; Nishimura M
BMC Pulm Med; 2006 Aug; 6():19. PubMed ID: 16895607
[TBL] [Abstract][Full Text] [Related]
2. Changing a hydrophobic heat and moisture exchanger after 48 hours rather than 24 hours: a clinical and microbiological evaluation.
Boisson C; Viviand X; Arnaud S; Thomachot L; Miliani Y; Martin C
Intensive Care Med; 1999 Nov; 25(11):1237-43. PubMed ID: 10654207
[TBL] [Abstract][Full Text] [Related]
3. Influence of ambient temperature and minute ventilation on passive and active heat and moisture exchangers.
Lellouche F; Qader S; Taillé S; Lyazidi A; Brochard L
Respir Care; 2014 May; 59(5):637-43. PubMed ID: 24106325
[TBL] [Abstract][Full Text] [Related]
4. In vitro and in vivo evaluation of a new active heat moisture exchanger.
Chiumello D; Pelosi P; Park G; Candiani A; Bottino N; Storelli E; Severgnini P; D'Onofrio D; Gattinoni L; Chiaranda M
Crit Care; 2004 Oct; 8(5):R281-8. PubMed ID: 15469569
[TBL] [Abstract][Full Text] [Related]
5. [Heat and moisture exchangers for conditioning of inspired air of intubated patients in intensive care. The humidification properties of passive air exchangers under clinical conditions].
Rathgeber J; Züchner K; Kietzmann D; Weyland W
Anaesthesist; 1995 Apr; 44(4):274-83. PubMed ID: 7785756
[TBL] [Abstract][Full Text] [Related]
6. Gradual reduction of endotracheal tube diameter during mechanical ventilation via different humidification devices.
Villafane MC; Cinnella G; Lofaso F; Isabey D; Harf A; Lemaire F; Brochard L
Anesthesiology; 1996 Dec; 85(6):1341-9. PubMed ID: 8968181
[TBL] [Abstract][Full Text] [Related]
7. Humidification during high-frequency oscillation ventilation is affected by ventilator circuit and ventilatory setting.
Chikata Y; Imanaka H; Onishi Y; Ueta M; Nishimura M
Paediatr Anaesth; 2009 Aug; 19(8):779-83. PubMed ID: 19624365
[TBL] [Abstract][Full Text] [Related]
8. Efficiency and safety of mechanical ventilation with a heat and moisture exchanger changed only once a week.
Ricard JD; Le Mière E; Markowicz P; Lasry S; Saumon G; Djedaïni K; Coste F; Dreyfuss D
Am J Respir Crit Care Med; 2000 Jan; 161(1):104-9. PubMed ID: 10619805
[TBL] [Abstract][Full Text] [Related]
9. Humidification performance of humidifying devices for tracheostomized patients with spontaneous breathing: a bench study.
Chikata Y; Oto J; Onodera M; Nishimura M
Respir Care; 2013 Sep; 58(9):1442-8. PubMed ID: 23386732
[TBL] [Abstract][Full Text] [Related]
10. Flow resistance, work of breathing of humidifiers, and endotracheal tubes in the hyperbaric chamber.
Arieli R; Daskalovic Y; Ertracht O; Arieli Y; Adir Y; Abramovich A; Halpern P
Am J Emerg Med; 2011 Sep; 29(7):725-30. PubMed ID: 20825878
[TBL] [Abstract][Full Text] [Related]
11. Heat and moisture exchangers in mechanically ventilated intensive care unit patients: a plea for an independent assessment of their performance.
Thiéry G; Boyer A; Pigné E; Salah A; De Lassence A; Dreyfuss D; Ricard JD
Crit Care Med; 2003 Mar; 31(3):699-704. PubMed ID: 12626972
[TBL] [Abstract][Full Text] [Related]
12. Double-heater-wire circuits and heat-and-moisture exchangers and the risk of ventilator-associated pneumonia.
Boots RJ; George N; Faoagali JL; Druery J; Dean K; Heller RF
Crit Care Med; 2006 Mar; 34(3):687-93. PubMed ID: 16505654
[TBL] [Abstract][Full Text] [Related]
13. The temperature and humidity in a low-flow anesthesia workstation with and without a heat and moisture exchanger.
de Castro J; Bolfi F; de Carvalho LR; Braz JR
Anesth Analg; 2011 Sep; 113(3):534-8. PubMed ID: 21680862
[TBL] [Abstract][Full Text] [Related]
14. Long-term mechanical ventilation with hygroscopic heat and moisture exchangers used for 48 hours: a prospective clinical, hygrometric, and bacteriologic study.
Boyer A; Thiéry G; Lasry S; Pigné E; Salah A; de Lassence A; Dreyfuss D; Ricard JD
Crit Care Med; 2003 Mar; 31(3):823-9. PubMed ID: 12626991
[TBL] [Abstract][Full Text] [Related]
15. Endotracheal temperature and humidity in laryngectomized patients in a warm and dry environment and the effect of a heat and moisture exchanger.
Scheenstra RJ; Muller SH; Hilgers FJ
Head Neck; 2011 Sep; 33(9):1285-93. PubMed ID: 21837698
[TBL] [Abstract][Full Text] [Related]
16. A New Method for
Filippini M; Serpelloni M; Quaranta V; Bellitti P; Sardini E; Latronico N
Pulm Med; 2019; 2019():9270615. PubMed ID: 30937191
[TBL] [Abstract][Full Text] [Related]
17. Comparison of three different humidification systems during prolonged mechanical ventilation.
Luchetti M; Stuani A; Castelli G; Marraro G
Minerva Anestesiol; 1998 Mar; 64(3):75-81. PubMed ID: 9677791
[TBL] [Abstract][Full Text] [Related]
18. Bedside evaluation of efficient airway humidification during mechanical ventilation of the critically ill.
Ricard JD; Markowicz P; Djedaini K; Mier L; Coste F; Dreyfuss D
Chest; 1999 Jun; 115(6):1646-52. PubMed ID: 10378563
[TBL] [Abstract][Full Text] [Related]
19. Long-term effects of different humidification systems on endotracheal tube patency: evaluation by the acoustic reflection method.
Jaber S; Pigeot J; Fodil R; Maggiore S; Harf A; Isabey D; Brochard L; Louis B
Anesthesiology; 2004 Apr; 100(4):782-8. PubMed ID: 15087611
[TBL] [Abstract][Full Text] [Related]
20. [Measurement of the humidity of inspired air in ventilated patients with various humidifer systems].
Christiansen S; Renzing K; Hirche H; Reidemeister JC
Anasthesiol Intensivmed Notfallmed Schmerzther; 1998 May; 33(5):300-5. PubMed ID: 9645289
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]