These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 16897167)

  • 21. Modified PMMA cements for a hydrolysis resistant metal-polymer interface in orthopaedic applications.
    Gbureck U; Grübel S; Thull R; Barralet JE
    Acta Biomater; 2005 Nov; 1(6):671-6. PubMed ID: 16701848
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Reinforcement of acrylic resins for provisional fixed restorations. Part III: effects of addition of titania and zirconia mixtures on some mechanical and physical properties.
    Panyayong W; Oshida Y; Andres CJ; Barco TM; Brown DT; Hovijitra S
    Biomed Mater Eng; 2002; 12(4):353-66. PubMed ID: 12652030
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Silicate coating of cemented titanium-based shafts in hip prosthetics reduces high aseptic loosening].
    Marx R; Faramarzi R; Jungwirth F; Kleffner BV; Mumme T; Weber M; Wirtz DC
    Z Orthop Unfall; 2009; 147(2):175-82. PubMed ID: 19358071
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Flexible fiber-reinforced composites with improved interfacial adhesion by mussel-inspired polydopamine and poly(methyl methacrylate) coating.
    Yi M; Sun H; Zhang H; Deng X; Cai Q; Yang X
    Mater Sci Eng C Mater Biol Appl; 2016 Jan; 58():742-9. PubMed ID: 26478367
    [TBL] [Abstract][Full Text] [Related]  

  • 25. PMMA-based bone cements containing magnetite particles for the hyperthermia of cancer.
    Kawashita M; Kawamura K; Li Z
    Acta Biomater; 2010 Aug; 6(8):3187-92. PubMed ID: 20197125
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Elastic and ultimate properties of acrylic bone cement reinforced with ultra-high-molecular-weight polyethylene fibers.
    Pourdeyhimi B; Wagner HD
    J Biomed Mater Res; 1989 Jan; 23(1):63-80. PubMed ID: 2708405
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Electrochemical properties of biocompatible material hardness modifications on titanium and steel under mechanical loads].
    Braun W; Walter U; Holbein R; Thull R
    Biomed Tech (Berl); 2005 Apr; 50(4):100-6. PubMed ID: 15884706
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Cemented fixation with PMMA or Bis-GMA resin hydroxyapatite cement: effect of implant surface roughness.
    Walsh WR; Svehla MJ; Russell J; Saito M; Nakashima T; Gillies RM; Bruce W; Hori R
    Biomaterials; 2004 Sep; 25(20):4929-34. PubMed ID: 15109853
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Mechanical and physical properties of carbon-graphite fiber-reinforced polymers intended for implant suprastructures.
    Segerström S; Ruyter IE
    Dent Mater; 2007 Sep; 23(9):1150-6. PubMed ID: 17118439
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Bone bonding ability and handling properties of a titania-polymethylmethacrylate (PMMA) composite bioactive bone cement modified with a unique PMMA powder.
    Fukuda C; Goto K; Imamura M; Neo M; Nakamura T
    Acta Biomater; 2011 Oct; 7(10):3595-600. PubMed ID: 21704200
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effect of bisphosphonates on anodized and heat-treated titanium surfaces: an animal experimental study.
    Lee SJ; Oh TJ; Bae TS; Lee MH; Soh Y; Kim BI; Kim HS
    J Periodontol; 2011 Jul; 82(7):1035-42. PubMed ID: 21189089
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Titania-containing bioactive bone cement for total hip arthroplasty in dogs.
    Imamura M; Goto K; Kawata T; Kataoka M; Fukuda C; Fujibayashi S; Matsuda S
    J Biomed Mater Res B Appl Biomater; 2019 May; 107(4):1238-1245. PubMed ID: 30261123
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Hydroxyapatite/titania composite bioactivity coating processed by the sol-gel method.
    Han JY; Yu ZT; Zhou L
    Biomed Mater; 2008 Dec; 3(4):044109. PubMed ID: 19029606
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Laser surface alloying of 316L stainless steel coated with a bioactive hydroxyapatite-titanium oxide composite.
    Ghaith el-S; Hodgson S; Sharp M
    J Mater Sci Mater Med; 2015 Feb; 26(2):83. PubMed ID: 25636972
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The effects of centrifugation and titanium fiber reinforcement on fatigue failure mechanisms in poly(methyl methacrylate) bone cement.
    Topoleski LD; Ducheyne P; Cuckler JM
    J Biomed Mater Res; 1995 Mar; 29(3):299-307. PubMed ID: 7615581
    [TBL] [Abstract][Full Text] [Related]  

  • 36. In vivo evaluation of bioactive PMMA-based bone cement with unchanged mechanical properties in a load-bearing model on rabbits.
    Fottner A; Nies B; Kitanovic D; Steinbrück A; Hausdorf J; Mayer-Wagner S; Pohl U; Jansson V
    J Biomater Appl; 2015 Jul; 30(1):30-7. PubMed ID: 25627649
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Improvement of mechanical properties of acrylic bone cement by fiber reinforcement.
    Saha S; Pal S
    J Biomech; 1984; 17(7):467-78. PubMed ID: 6480622
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Photoexcited formation of bone apatite-like coatings on micro-arc oxidized titanium.
    Han Y; Xu K
    J Biomed Mater Res A; 2004 Dec; 71(4):608-14. PubMed ID: 15499638
    [TBL] [Abstract][Full Text] [Related]  

  • 39. TF-XRD examination of surface-reactive TiO2 coatings produced by heat treatment and CO2 laser treatment.
    Moritz N; Areva S; Wolke J; Peltola T
    Biomaterials; 2005 Jul; 26(21):4460-7. PubMed ID: 15701375
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Oxidized titanium screws coated with calcium ions and their performance in rabbit bone.
    Sul YT; Johansson CB; Albrektsson T
    Int J Oral Maxillofac Implants; 2002; 17(5):625-34. PubMed ID: 12381062
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.