These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

1126 related articles for article (PubMed ID: 16905081)

  • 1. Comparison of direct and video-assisted views of the larynx during routine intubation.
    Kaplan MB; Hagberg CA; Ward DS; Brambrink A; Chhibber AK; Heidegger T; Lozada L; Ovassapian A; Parsons D; Ramsay J; Wilhelm W; Zwissler B; Gerig HJ; Hofstetter C; Karan S; Kreisler N; Pousman RM; Thierbach A; Wrobel M; Berci G
    J Clin Anesth; 2006 Aug; 18(5):357-62. PubMed ID: 16905081
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Management of the predicted difficult airway: a comparison of conventional blade laryngoscopy with video-assisted blade laryngoscopy and the GlideScope.
    Serocki G; Bein B; Scholz J; Dörges V
    Eur J Anaesthesiol; 2010 Jan; 27(1):24-30. PubMed ID: 19809328
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Pentax-AWS((R)) rigid indirect video laryngoscope: clinical assessment of performance in 320 cases.
    Suzuki A; Toyama Y; Katsumi N; Kunisawa T; Sasaki R; Hirota K; Henderson JJ; Iwasaki H
    Anaesthesia; 2008 Jun; 63(6):641-7. PubMed ID: 18477277
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A Macintosh laryngoscope blade for videolaryngoscopy reduces stylet use in patients with normal airways.
    van Zundert A; Maassen R; Lee R; Willems R; Timmerman M; Siemonsma M; Buise M; Wiepking M
    Anesth Analg; 2009 Sep; 109(3):825-31. PubMed ID: 19690253
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Improved glottic exposure with the Video Macintosh Laryngoscope in adult emergency department tracheal intubations.
    Brown CA; Bair AE; Pallin DJ; Laurin EG; Walls RM;
    Ann Emerg Med; 2010 Aug; 56(2):83-8. PubMed ID: 20202720
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A comparison of the STORZ video laryngoscope and standard direct laryngoscopy for intubation in the Pediatric airway--a randomized clinical trial.
    Vlatten A; Aucoin S; Litz S; Macmanus B; Soder C
    Paediatr Anaesth; 2009 Nov; 19(11):1102-7. PubMed ID: 19708910
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A clinical comparison of the Flexiblade and Macintosh laryngoscopes for laryngeal exposure in anesthetized adults.
    Cheung RW; Irwin MG; Law BC; Chan CK
    Anesth Analg; 2006 Feb; 102(2):626-30. PubMed ID: 16428574
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Direct versus indirect laryngoscopic visualization in human endotracheal intubation: a tool for virtual anesthesia practice and teleanesthesiology.
    Boedeker BH; Berg BW; Bernhagen M; Murray WB
    Stud Health Technol Inform; 2008; 132():31-6. PubMed ID: 18391251
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Videolaryngoscopy in the management of the difficult airway: a comparison with the Macintosh blade.
    Stroumpoulis K; Pagoulatou A; Violari M; Ikonomou I; Kalantzi N; Kastrinaki K; Xanthos T; Michaloliakou C
    Eur J Anaesthesiol; 2009 Mar; 26(3):218-22. PubMed ID: 19237983
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Pentax-AWS improves laryngeal view compared with Macintosh blade during laryngoscopy and facilitates easier intubation].
    Suzuki A; Toyama Y; Katsumi N; Sasaki R; Hirota K; Matsumoto H; Takahata O; Iwasaki H
    Masui; 2007 Apr; 56(4):464-8. PubMed ID: 17441461
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The clinical assessment of Glidescope in orotracheal intubation under general anesthesia.
    Xue FS; Zhang GH; Liu J; Li XY; Yang QY; Xu YC; Li CW
    Minerva Anestesiol; 2007 Sep; 73(9):451-7. PubMed ID: 17660737
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of the Truview PCD™ and the GlideScope(®) video laryngoscopes with direct laryngoscopy in pediatric patients: a randomized trial.
    Riveros R; Sung W; Sessler DI; Sanchez IP; Mendoza ML; Mascha EJ; Niezgoda J
    Can J Anaesth; 2013 May; 60(5):450-7. PubMed ID: 23435693
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Poor visualization during direct laryngoscopy and high upper lip bite test score are predictors of difficult intubation with the GlideScope videolaryngoscope.
    Tremblay MH; Williams S; Robitaille A; Drolet P
    Anesth Analg; 2008 May; 106(5):1495-500, table of contents. PubMed ID: 18420866
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of intubation success of video laryngoscopy versus direct laryngoscopy in the difficult airway using high-fidelity simulation.
    Narang AT; Oldeg PF; Medzon R; Mahmood AR; Spector JA; Robinett DA
    Simul Healthc; 2009; 4(3):160-5. PubMed ID: 19680083
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of the C-MAC videolaryngoscope with the Macintosh, Glidescope, and Airtraq laryngoscopes in easy and difficult laryngoscopy scenarios in manikins.
    McElwain J; Malik MA; Harte BH; Flynn NM; Laffey JG
    Anaesthesia; 2010 May; 65(5):483-9. PubMed ID: 20337620
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparative effectiveness of the C-MAC video laryngoscope versus direct laryngoscopy in the setting of the predicted difficult airway.
    Aziz MF; Dillman D; Fu R; Brambrink AM
    Anesthesiology; 2012 Mar; 116(3):629-36. PubMed ID: 22261795
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Pediatric airway management: comparing the Berci-Kaplan Video Laryngoscope with direct laryngoscopy.
    Macnair D; Baraclough D; Wilson G; Bloch M; Engelhardt T
    Paediatr Anaesth; 2009 Jun; 19(6):577-80. PubMed ID: 19645975
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of three video laryngoscopy devices to direct laryngoscopy for intubating obese patients: a randomized controlled trial.
    Yumul R; Elvir-Lazo OL; White PF; Sloninsky A; Kaplan M; Kariger R; Naruse R; Parker N; Pham C; Zhang X; Wender RH
    J Clin Anesth; 2016 Jun; 31():71-7. PubMed ID: 27185681
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improvement in glottic visualisation by using the C-MAC PM video laryngoscope as a first-line device for out-of-hospital emergency tracheal intubation: An observational study.
    Hossfeld B; Frey K; Doerges V; Lampl L; Helm M
    Eur J Anaesthesiol; 2015 Jun; 32(6):425-31. PubMed ID: 25886716
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A comparison of three videolaryngoscopes: the Macintosh laryngoscope blade reduces, but does not replace, routine stylet use for intubation in morbidly obese patients.
    Maassen R; Lee R; Hermans B; Marcus M; van Zundert A
    Anesth Analg; 2009 Nov; 109(5):1560-5. PubMed ID: 19713258
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 57.