These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

202 related articles for article (PubMed ID: 16905126)

  • 1. Integrated and automatic mixing of whole blood: an evaluation of a novel blood gas analyzer.
    Grenache DG; Parker C
    Clin Chim Acta; 2007 Jan; 375(1-2):153-7. PubMed ID: 16905126
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation and advantages of an automatic magnetic mixing of syringes integrated to a whole blood gas analyser.
    Benoit MO; Paul JL
    Scand J Clin Lab Invest; 2009; 69(5):628-32. PubMed ID: 19391061
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical and statistical evaluation of 1st Automatic: a pilot study.
    Andersen AT; Nielsen NB; Trudslev M; Bakhshaie B; Pedersen S; Hejlesen O
    Stud Health Technol Inform; 2009; 150():389-93. PubMed ID: 19745338
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Different manufacturers of syringes: a new source of variability in blood gas, acid-base balance and related laboratory test?
    Lima-Oliveira G; Lippi G; Salvagno GL; Montagnana M; Picheth G; Guidi GC
    Clin Biochem; 2012 Jun; 45(9):683-7. PubMed ID: 22440459
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of blood gas, electrolyte and metabolite results measured with two different blood gas analyzers and a core laboratory analyzer.
    Uyanik M; Sertoglu E; Kayadibi H; Tapan S; Serdar MA; Bilgi C; Kurt I
    Scand J Clin Lab Invest; 2015 Apr; 75(2):97-105. PubMed ID: 25431133
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effects of syringe material, sample storage time, and temperature on blood gases and oxygen saturation in arterialized human blood samples.
    Knowles TP; Mullin RA; Hunter JA; Douce FH
    Respir Care; 2006 Jul; 51(7):732-6. PubMed ID: 16800906
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Neonate capillary blood gas reference values.
    Cousineau J; Anctil S; Carceller A; Gonthier M; Delvin EE
    Clin Biochem; 2005 Oct; 38(10):905-7. PubMed ID: 16109393
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The use of serial patient blood gas, electrolyte and glucose results to derive biologic variation: a new tool to assess the acceptability of intensive care unit testing.
    Cembrowski GS; Tran DV; Higgins TN
    Clin Chem Lab Med; 2010 Oct; 48(10):1447-54. PubMed ID: 20716012
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influence of spurious hemolysis on blood gas analysis.
    Lippi G; Fontana R; Avanzini P; Sandei F; Ippolito L
    Clin Chem Lab Med; 2013 Aug; 51(8):1651-4. PubMed ID: 23314547
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Preanalytical mixing of whole-blood specimens in the context of the Athlete Passport.
    Ashenden M; Clarke A; Sharpe K; d'Onofrio G; Allbon G; Gore CJ
    J Clin Pathol; 2012 Jan; 65(1):8-13. PubMed ID: 22049219
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of a hand-held blood gas analyzer for rapid determination of blood gases, electrolytes and metabolites in intensive care setting.
    Luukkonen AA; Lehto TM; Hedberg PS; Vaskivuo TE
    Clin Chem Lab Med; 2016 Apr; 54(4):585-94. PubMed ID: 26457784
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of a portable clinical analyzer in cynomolgus Macaques (Macaca fasicularis).
    Hopper KJ; Cray C
    J Am Assoc Lab Anim Sci; 2007 May; 46(3):53-7. PubMed ID: 17487954
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of automatic mixing versus manual mixing for point of care hemoglobin measurement.
    Altawallbeh G; Castaneda P; Wennecke G; Karger AB
    Pract Lab Med; 2020 May; 20():e00163. PubMed ID: 32322646
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Got pure blood in fetal rats?
    Mao C; Guan J; Yuan X; Miao Y; Zhu H; Chen L; Lv J; Xu F; Liu Y; Hui P; Zhu Y; Xu Z
    Pediatr Hematol Oncol; 2007 Sep; 24(6):457-60. PubMed ID: 17710664
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Application of miniaturized sensors in clinical and laboratory setting for measuring blood analytes including glucose and lactate.
    Mansouri S
    Ann Biol Clin (Paris); 2003; 61(2):193-8. PubMed ID: 12702474
    [No Abstract]   [Full Text] [Related]  

  • 16. A comparison of syringes to collect blood for analysis of gases, electrolytes and glucose.
    Carter BG; Tibballs J; Hochmann M; Osborne A; Chiriano A; Murray G
    Anaesth Intensive Care; 1994 Dec; 22(6):698-702. PubMed ID: 7892975
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The serum anion gap. Has the reference interval really fallen?
    Roberts WL; Johnson RD
    Arch Pathol Lab Med; 1997 Jun; 121(6):568-72. PubMed ID: 9199620
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of an improved blood-conserving POCT sampling system.
    Weiss M; Dullenkopf A; Moehrlen U
    Clin Biochem; 2004 Nov; 37(11):977-84. PubMed ID: 15498525
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measurement of ionized calcium in canine blood samples collected in prefilled and self-filled heparinized syringes using the i-STAT point-of-care analyzer.
    Tappin S; Rizzo F; Dodkin S; Papasouliotis K; Tasker S; Murphy K
    Vet Clin Pathol; 2008 Mar; 37(1):66-72. PubMed ID: 18366547
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Potential preanalytical errors in whole-blood analysis: effect of syringe sample volume on blood gas, electrolyte and lactate values.
    Hedberg P; Majava A; Kiviluoma K; Ohtonen P
    Scand J Clin Lab Invest; 2009; 69(5):585-91. PubMed ID: 19396657
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.