BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

81 related articles for article (PubMed ID: 16906090)

  • 1. How do serum cobalt and chromium levels change after metal-on-metal hip resurfacing?
    Vendittoli PA; Lavigne M; Roy AG
    Clin Orthop Relat Res; 2006 Oct; 451():292-3; author reply 293. PubMed ID: 16906090
    [No Abstract]   [Full Text] [Related]  

  • 2. Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty.
    Witzleb WC; Ziegler J; Krummenauer F; Neumeister V; Guenther KP
    Acta Orthop; 2006 Oct; 77(5):697-705. PubMed ID: 17068698
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Distribution of chromium and cobalt ions in various blood fractions after resurfacing hip arthroplasty.
    Walter LR; Marel E; Harbury R; Wearne J
    J Arthroplasty; 2008 Sep; 23(6):814-21. PubMed ID: 18534545
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Serum metal ion levels after second-generation metal-on-metal total hip arthroplasty.
    Imanishi T; Hasegawa M; Sudo A
    Arch Orthop Trauma Surg; 2010 Dec; 130(12):1447-50. PubMed ID: 20111868
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Serum metal levels and bearing surfaces in total hip arthroplasty.
    Rasquinha VJ; Ranawat CS; Weiskopf J; Rodriguez JA; Skipor AK; Jacobs JJ
    J Arthroplasty; 2006 Sep; 21(6 Suppl 2):47-52. PubMed ID: 16950061
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Serum cobalt and serum chromium level in 2 patients with chronic renal failure after total hip prosthesis implantation with metal-metal gliding contact].
    Brodner W; Grohs JG; Bitzan P; Meisinger V; Kovarik J; Kotz R
    Z Orthop Ihre Grenzgeb; 2000; 138(5):425-9. PubMed ID: 11084743
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Current in vivo wear of metal-on-metal bearings assessed by exercise-related rise in plasma cobalt level.
    Khan M; Takahashi T; Kuiper JH; Sieniawska CE; Takagi K; Richardson JB
    J Orthop Res; 2006 Nov; 24(11):2029-35. PubMed ID: 16960848
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Re: Serum metal levels and bearing surfaces in total hip arthroplasty.
    Bilgili MG
    J Arthroplasty; 2008 Jan; 23(1):156; author reply 156-7. PubMed ID: 18165048
    [No Abstract]   [Full Text] [Related]  

  • 9. Reducing metal ion release following hip resurfacing arthroplasty.
    Langton DJ; Joyce TJ; Mangat N; Lord J; Van Orsouw M; De Smet K; Nargol AV
    Orthop Clin North Am; 2011 Apr; 42(2):169-80, viii. PubMed ID: 21435493
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Serum metal ion exposure after total knee arthroplasty.
    Luetzner J; Krummenauer F; Lengel AM; Ziegler J; Witzleb WC
    Clin Orthop Relat Res; 2007 Aug; 461():136-42. PubMed ID: 17438467
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Metal ion levels following resurfacing arthroplasty of the hip: serial results over a ten-year period.
    deSouza RM; Parsons NR; Oni T; Dalton P; Costa M; Krikler S
    J Bone Joint Surg Br; 2010 Dec; 92(12):1642-7. PubMed ID: 21119168
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements.
    Lhotka C; Szekeres T; Steffan I; Zhuber K; Zweymüller K
    J Orthop Res; 2003 Mar; 21(2):189-95. PubMed ID: 12568948
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Serum levels of cobalt and chromium in patients with Sikomet metal-metal total hip replacements.
    Milosev I; Pisot V; Campbell P
    J Orthop Res; 2005 May; 23(3):526-35. PubMed ID: 15885471
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Systemic metal exposure in large- and small-diameter metal-on-metal total hip replacements.
    Daniel J; Ziaee H; Pradhan C; McMinn DJ
    Orthopedics; 2008 Dec; 31(12 Suppl 2):. PubMed ID: 19298017
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Release of cobalt and chromium ions into the serum following implantation of the metal-on-metal Maverick-type artificial lumbar disc (Medtronic Sofamor Danek).
    Zeh A; Planert M; Siegert G; Lattke P; Held A; Hein W
    Spine (Phila Pa 1976); 2007 Feb; 32(3):348-52. PubMed ID: 17268267
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Does intraoperative cell salvage remove cobalt and chromium from reinfused blood?
    Reijngoud LW; Pattyn C; De Haan R; De Somer F; Campbell PA; Gill HS; De Smet KA
    J Arthroplasty; 2009 Oct; 24(7):1125-9. PubMed ID: 18789632
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Serum ion levels after ceramic-on-ceramic and metal-on-metal total hip arthroplasty: 8-year minimum follow-up.
    Savarino L; Padovani G; Ferretti M; Greco M; Cenni E; Perrone G; Greco F; Baldini N; Giunti A
    J Orthop Res; 2008 Dec; 26(12):1569-76. PubMed ID: 18634038
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Metal-on-metal hip implants: do they impair renal function in the long-term? A 10-year follow-up study.
    Marker M; Grübl A; Riedl O; Heinze G; Pohanka E; Kotz R
    Arch Orthop Trauma Surg; 2008 Sep; 128(9):915-9. PubMed ID: 17940781
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Serum chromium levels before and after revision surgery for loosened metal-on-metal total hip arthroplasty.
    Maezawa K; Nozawa M; Matsuda K; Sugimoto M; Shitoto K; Kurosawa H
    J Arthroplasty; 2009 Jun; 24(4):549-53. PubMed ID: 18534450
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Metal ion levels in a triathlete with a metal-on-metal resurfacing arthroplasty of the hip.
    De Haan R; Campbell P; Reid S; Skipor AK; De Smet K
    J Bone Joint Surg Br; 2007 Apr; 89(4):538-41. PubMed ID: 17463127
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.