These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 16911151)

  • 1. In vitro study of the ilial anatomic landmarks for safe implant insertion in the first sacral vertebra of the intact canine sacroiliac joint.
    Joseph R; Milgram J; Zhan K; Shahar R
    Vet Surg; 2006 Aug; 35(6):510-7. PubMed ID: 16911151
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Implantation of iliosacral screws. Simulation of optimal placement by 3-dimensional X-ray computed tomography].
    Tonetti J; Cloppet O; Clerc M; Pittet L; Troccaz J; Merloz P; Chirossel J
    Rev Chir Orthop Reparatrice Appar Mot; 2000 Jun; 86(4):360-9. PubMed ID: 10880935
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Canine sacroiliac luxation: anatomic study of the craniocaudal articular surface angulation of the sacrum to define a safe corridor in the dorsal plane for placement of screws used for fixation in lag fashion.
    Bowlt KL; Shales CJ
    Vet Surg; 2011 Jan; 40(1):22-6. PubMed ID: 21077923
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Sacroiliac luxation in the cat: defining a safe corridor in the dorsoventral plane for screw insertion in lag fashion.
    Shales CJ; White L; Langley-Hobbs SJ
    Vet Surg; 2009 Apr; 38(3):343-8. PubMed ID: 19573097
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Anatomic and experimental basis for the insertion of a screw at the first sacral vertebra.
    de Peretti F; Argenson C; Bourgeon A; Omar F; Eude P; Aboulker C
    Surg Radiol Anat; 1991; 13(2):133-7. PubMed ID: 1925915
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Transsacral versus modified pelvic landmarks for percutaneous iliosacral screw placement--a computed tomographic analysis and cadaveric study.
    Day CS; Prayson MJ; Shuler TE; Towers J; Gruen GS
    Am J Orthop (Belle Mead NJ); 2000 Sep; 29(9 Suppl):16-21. PubMed ID: 11011775
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Morphometric anatomical and CT study of the human adult sacroiliac region.
    Postacchini R; Trasimeni G; Ripani F; Sessa P; Perotti S; Postacchini F
    Surg Radiol Anat; 2017 Jan; 39(1):85-94. PubMed ID: 27324173
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Canine sacroiliac luxation: anatomic study of dorsoventral articular surface angulation and safe corridor for placement of screws used for lag fixation.
    Shales CJ; Langley-Hobbs SJ
    Vet Surg; 2005; 34(4):324-31. PubMed ID: 16212586
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Feasibility and accuracy of ultrasound-guided sacroiliac joint injection in dogs.
    Jones JC; Gonzalez LM; Larson MM; Freeman LE; Werre SR
    Vet Radiol Ultrasound; 2012; 53(4):446-54. PubMed ID: 22548612
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The lateral sacral triangle--a decision support for secure transverse sacroiliac screw insertion.
    Mendel T; Noser H; Wohlrab D; Stock K; Radetzki F
    Injury; 2011 Oct; 42(10):1164-70. PubMed ID: 22081808
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [A morphologic evaluation of the sacroiliac joint and plate fixation on a pelvic model using a S1 pedicular screw, transiliosacral screws, and a compression rod for sacroiliac joint injuries].
    Esenkaya I
    Acta Orthop Traumatol Turc; 2002; 36(5):432-41. PubMed ID: 12594352
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ventral abdominal approach for screw fixation of sacroiliac luxation in cadavers of cats and dogs.
    Borer LR; Voss K; Montavon PM
    Am J Vet Res; 2008 Apr; 69(4):542-8. PubMed ID: 18380588
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of open reduction versus minimally invasive surgical approaches on screw position in canine sacroiliac lag-screw fixation.
    Déjardin LM; Marturello DM; Guiot LP; Guillou RP; DeCamp CE
    Vet Comp Orthop Traumatol; 2016 Jul; 29(4):290-7. PubMed ID: 27189510
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The iliac buttress. A computed tomographic study of sacral anatomy.
    Jackson RP; McManus AC
    Spine (Phila Pa 1976); 1993 Aug; 18(10):1318-28. PubMed ID: 8211364
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Is the lateral sacral fluoroscopic view essential for accurate percutaneous sacroiliac screw insertion? An experimental study.
    Giannoudis PV; Papadokostakis G; Alpantaki K; Kontakis G; Chalidis B
    Injury; 2008 Aug; 39(8):875-80. PubMed ID: 18550059
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cross-sectional geometry of the sacral ala for safe insertion of iliosacral lag screws: a computed tomography model.
    Noojin FK; Malkani AL; Haikal L; Lundquist C; Voor MJ
    J Orthop Trauma; 2000 Jan; 14(1):31-5. PubMed ID: 10630800
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Parameters of lengthened sacroiliac screw fixation: a radiological anatomy study.
    Zhao Y; Li J; Wang D; Lian W
    Eur Spine J; 2012 Sep; 21(9):1807-14. PubMed ID: 22610442
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Sacro-Iliac Joint Sensory Block and Radiofrequency Ablation: Assessment of Bony Landmarks Relevant for Image-Guided Procedures.
    Robinson TJ; Roberts SL; Burnham RS; Loh E; Agur AM
    Biomed Res Int; 2016; 2016():1432074. PubMed ID: 27747222
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Anatomical considerations for percutaneous trans ilio-sacroiliac S1 and S2 screw placement.
    König MA; Sundaram RO; Saville P; Jehan S; Boszczyk BM
    Eur Spine J; 2016 Jun; 25(6):1800-5. PubMed ID: 26577394
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biomechanical effects of transverse partial sacrectomy on the sacroiliac joints: an in vitro human cadaveric investigation of the borderline of sacroiliac joint instability.
    Yu B; Zheng Z; Zhuang X; Chen H; Xie D; Luk KD; Lu WW
    Spine (Phila Pa 1976); 2009 Jun; 34(13):1370-5. PubMed ID: 19478657
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.