These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 16911341)

  • 1. Protocol for optimal detection and exclusion of a patent foramen ovale using transthoracic echocardiography with agitated saline microbubbles.
    Attaran RR; Ata I; Kudithipudi V; Foster L; Sorrell VL
    Echocardiography; 2006 Aug; 23(7):616-22. PubMed ID: 16911341
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The cough test is superior to the Valsalva maneuver in the delineation of right-to-left shunting through a patent foramen ovale during contrast transesophageal echocardiography.
    Stoddard MF; Keedy DL; Dawkins PR
    Am Heart J; 1993 Jan; 125(1):185-9. PubMed ID: 8417516
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Importance of Abdominal Compression Valsalva Maneuver and Microbubble Grading in Contrast Transthoracic Echocardiography for Detecting Patent Foramen Ovale.
    Takaya Y; Watanabe N; Ikeda M; Akagi T; Nakayama R; Nakagawa K; Toh N; Ito H
    J Am Soc Echocardiogr; 2020 Feb; 33(2):201-206. PubMed ID: 31837927
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Importance of an adequately performed Valsalva maneuver for detecting a right-to-left shunt indicating foramen ovale reopening.
    Wei D; Ju Y
    J Ultrasound Med; 2015 May; 34(5):879-83. PubMed ID: 25911721
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Agitated saline versus polygelatine for the echocardiographic assessment of patent foramen ovale.
    Buttignoni SC; Khorsand A; Mundigler G; Bergler-Klein J; Heger M; Zehetgruber M; Baumgartner H; Binder T
    J Am Soc Echocardiogr; 2004 Oct; 17(10):1059-65. PubMed ID: 15452472
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Significance of left-sided heart disease for the detection of patent foramen ovale by transesophageal contrast echocardiography.
    Siostrzonek P; Lang W; Zangeneh M; Gössinger H; Stümpflen A; Rosenmayr G; Heinz G; Schwarz M; Zeiler K; Mösslacher H
    J Am Coll Cardiol; 1992 May; 19(6):1192-6. PubMed ID: 1564219
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Detection of right to left shunting through a patent foramen ovale in Japanese patients with ischemic stroke by transesophageal echocardiography using a standardized Valsalva maneuver.
    Yoshida M; Goto S; Aikawa M; Oguma T; Nakajima T; Abe S; Kumagai A; Hoshiba Y; Tanabe T; Handa S; Yamamoto M
    Tokai J Exp Clin Med; 2005 Dec; 30(4):211-6. PubMed ID: 16482941
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Inferior Vena Cava Compression as a Novel Maneuver to Detect Patent Foramen Ovale: A Transesophageal Echocardiographic Study.
    Yamashita E; Murata T; Goto E; Fujiwara T; Sasaki T; Minami K; Nakamura K; Kumagai K; Naito S; Kario K; Oshima S
    J Am Soc Echocardiogr; 2017 Mar; 30(3):292-299. PubMed ID: 28024853
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of transthoracic versus transesophageal echocardiography for detection of right-to-left atrial shunting using agitated saline contrast.
    Thanigaraj S; Valika A; Zajarias A; Lasala JM; Perez JE
    Am J Cardiol; 2005 Oct; 96(7):1007-10. PubMed ID: 16188533
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Detection of patent foramen ovale by contrast transesophageal echocardiography.
    Chen WJ; Kuan P; Lien WP; Lin FY
    Chest; 1992 Jun; 101(6):1515-20. PubMed ID: 1600767
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Enhanced detection of patent foramen ovale by systematic transthoracic saline contrast echocardiography.
    Lam YY; Yu CM; Zhang Q; Yan BP; Yip GW
    Int J Cardiol; 2011 Oct; 152(1):24-7. PubMed ID: 20619473
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The frequency of patent foramen ovale in patients with ischemic stroke: a transesophageal echocardiographic study.
    Chen WJ; Lin SL; Cheng JJ; Lien WP
    J Formos Med Assoc; 1991 Aug; 90(8):744-8. PubMed ID: 1683366
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A critical review of patent foramen ovale detection using saline contrast echocardiography: when bubbles lie.
    Woods TD; Patel A
    J Am Soc Echocardiogr; 2006 Feb; 19(2):215-22. PubMed ID: 16455428
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Asymptomatic cerebral infarction associated with a patent foramen ovale and atrial septal aneurysm].
    Yonemitsu M; Hashimoto Y; Ohbayashi K; Kimura K; Uchino M
    Rinsho Shinkeigaku; 1998 Jan; 38(1):66-9. PubMed ID: 9597916
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Transthoracic echocardiography using second harmonic imaging with Valsalva manoeuvre for the detection of right to left shunts.
    Clarke NR; Timperley J; Kelion AD; Banning AP
    Eur J Echocardiogr; 2004 Jun; 5(3):176-81. PubMed ID: 15147659
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The detection of interatrial flow patency in awake and anesthetized patients: a comparative study using transnasal transesophageal echocardiography.
    Greim CA; Trautner H; Krämer K; Zimmermann P; Apfel CC; Roewer N
    Anesth Analg; 2001 May; 92(5):1111-6. PubMed ID: 11323330
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Platypnea-orthodeoxia of a 69-year old woman with a patent foramen ovale].
    Dogu E; Stöhr A; Zick-Bögemann R; Hegeler-Molkewehrum C; Hartmann H; Engel HJ
    Z Kardiol; 2004 May; 93(5):403-6. PubMed ID: 15160276
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Detection of right-to-left atrial communication using agitated saline contrast imaging: experience with 1162 patients and recommendations for echocardiography.
    Marriott K; Manins V; Forshaw A; Wright J; Pascoe R
    J Am Soc Echocardiogr; 2013 Jan; 26(1):96-102. PubMed ID: 23072711
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Second harmonic transthoracic echocardiography: the new reference screening method for the detection of patent foramen ovale.
    Daniëls C; Weytjens C; Cosyns B; Schoors D; De Sutter J; Paelinck B; Muyldermans L; Van Camp G
    Eur J Echocardiogr; 2004 Dec; 5(6):449-52. PubMed ID: 15556821
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Patent foramen ovale not so patent.
    López-Haldón J; López-Pardo F; Rodríguez-Puras MJ; Martínez-Martínez A
    Echocardiography; 2009 Apr; 26(4):465-8. PubMed ID: 19017320
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.