21. Is the second phase of a biphasic defibrillation waveform the defibrillating phase? Hillsley RE; Walker RG; Swanson DK; Rollins DL; Wolf PD; Smith WM; Ideker RE Pacing Clin Electrophysiol; 1993 Jul; 16(7 Pt 1):1401-11. PubMed ID: 7689206 [TBL] [Abstract][Full Text] [Related]
22. The effects of biphasic and conventional monophasic defibrillation on postresuscitation myocardial function. Tang W; Weil MH; Sun S; Yamaguchi H; Povoas HP; Pernat AM; Bisera J J Am Coll Cardiol; 1999 Sep; 34(3):815-22. PubMed ID: 10483965 [TBL] [Abstract][Full Text] [Related]
23. Predicting the relative efficacy of shock waveforms for transthoracic defibrillation in dogs. White JB; Walcott GP; Wayland JL; Smith WM; Ideker RE Ann Emerg Med; 1999 Sep; 34(3):309-20. PubMed ID: 10459086 [TBL] [Abstract][Full Text] [Related]
24. Optimization of transthoracic ventricular defibrillation-biphasic and triphasic shocks, waveform rounding, and synchronized shock delivery. Kidwai BJ; McIntyre A; Anderson J; Adgey AA J Electrocardiol; 2002 Jul; 35(3):235-44. PubMed ID: 12122614 [TBL] [Abstract][Full Text] [Related]
25. Ascending-ramp biphasic waveform has a lower defibrillation threshold and releases less troponin I than a truncated exponential biphasic waveform. Huang J; Walcott GP; Ruse RB; Bohanan SJ; Killingsworth CR; Ideker RE Circulation; 2012 Sep; 126(11):1328-33. PubMed ID: 22865891 [TBL] [Abstract][Full Text] [Related]
26. Novel rectangular biphasic and monophasic waveforms delivered by a radiofrequency-powered defibrillator compared with conventional capacitor-based waveforms in transvenous cardioversion of atrial fibrillation. Walsh SJ; Manoharan G; Escalona OJ; Santos J; Evans N; Anderson JM; Stevenson M; Allen JD; Adgey AA Europace; 2006 Oct; 8(10):873-80. PubMed ID: 17000635 [TBL] [Abstract][Full Text] [Related]
27. Increasing fibrillation duration enhances relative asymmetrical biphasic versus monophasic defibrillator waveform efficacy. Jones JL; Swartz JF; Jones RE; Fletcher R Circ Res; 1990 Aug; 67(2):376-84. PubMed ID: 2376078 [TBL] [Abstract][Full Text] [Related]
28. Effect of electrode polarity on internal defibrillation with monophasic and biphasic waveforms using an endocardial lead system. Huang J; KenKnight BH; Walcott GP; Walker RG; Smith WM; Ideker RE J Cardiovasc Electrophysiol; 1997 Feb; 8(2):161-71. PubMed ID: 9048247 [TBL] [Abstract][Full Text] [Related]
29. Effects of biphasic waveforms on outcomes of cardiopulmonary resuscitation in a porcine model of prolonged cardiac arrest. Chang YT; Tang W; Wang J; Brewer JE; Freeman G; Sun S; Weil MH Crit Care Med; 2006 Dec; 34(12):3024-8. PubMed ID: 17075369 [TBL] [Abstract][Full Text] [Related]
30. Ventricular pacing threshold after transthoracic external defibrillation with two different waveforms: an experimental study. Assumpção AC; de Oliveira PP; Vilarinho KA; Eghtesady P; Silveira Filho LM; Lavagnoli CF; Severino ES; Petrucci O Europace; 2013 Feb; 15(2):297-302. PubMed ID: 23143858 [TBL] [Abstract][Full Text] [Related]
31. Ventricular defibrillation using biphasic waveforms: the importance of phasic duration. Tang AS; Yabe S; Wharton JM; Dolker M; Smith WM; Ideker RE J Am Coll Cardiol; 1989 Jan; 13(1):207-14. PubMed ID: 2909569 [TBL] [Abstract][Full Text] [Related]
33. A comparison of biphasic and monophasic waveform defibrillation after prolonged ventricular fibrillation. Tang W; Weil MH; Sun S; Povoas HP; Klouche K; Kamohara T; Bisera J Chest; 2001 Sep; 120(3):948-54. PubMed ID: 11555534 [TBL] [Abstract][Full Text] [Related]
34. A randomized controlled trial of efficacy and ST change following use of the Welch-Allyn MRL PIC biphasic waveform versus damped sine monophasic waveform for external DC cardioversion. Ambler JJ; Deakin CD Resuscitation; 2006 Nov; 71(2):146-51. PubMed ID: 16987583 [TBL] [Abstract][Full Text] [Related]
35. The effects of second and third phase duration on defibrillation efficacy of triphasic rectangle waveforms. Tang C; Wang P; Gong Y; Wei L; Li Y; Zhang S Resuscitation; 2016 May; 102():57-62. PubMed ID: 26939971 [TBL] [Abstract][Full Text] [Related]
37. The effects of biphasic waveform design on post-resuscitation myocardial function. Tang W; Weil MH; Sun S; Jorgenson D; Morgan C; Klouche K; Snyder D J Am Coll Cardiol; 2004 Apr; 43(7):1228-35. PubMed ID: 15063435 [TBL] [Abstract][Full Text] [Related]
38. Improved low energy defibrillation efficacy in man with the use of a biphasic truncated exponential waveform. Winkle RA; Mead RH; Ruder MA; Gaudiani V; Buch WS; Pless B; Sweeney M; Schmidt P Am Heart J; 1989 Jan; 117(1):122-7. PubMed ID: 2911965 [TBL] [Abstract][Full Text] [Related]
39. Comparison of rectilinear biphasic waveform with biphasic truncated exponential waveform in a pediatric defibrillation model. Wang J; Tang W; Brewer JE; Freeman G; Chang YT; Weil MH Crit Care Med; 2007 Aug; 35(8):1961-5. PubMed ID: 17581484 [TBL] [Abstract][Full Text] [Related]