These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
363 related articles for article (PubMed ID: 16922469)
1. Use of a compact pixellated gamma camera for small animal pinhole SPECT imaging. Zeniya T; Watabe H; Aoi T; Kim KM; Teramoto N; Takeno T; Ohta Y; Hayashi T; Mashino H; Ota T; Yamamoto S; Iida H Ann Nucl Med; 2006 Jul; 20(6):409-16. PubMed ID: 16922469 [TBL] [Abstract][Full Text] [Related]
2. Evaluating performance of a pixel array semiconductor SPECT system for small animal imaging. Kubo N; Zhao S; Fujiki Y; Kinda A; Motomura N; Katoh C; Shiga T; Kawashima H; Kuge Y; Tamaki N Ann Nucl Med; 2005 Oct; 19(7):633-9. PubMed ID: 16363631 [TBL] [Abstract][Full Text] [Related]
3. Molecular imaging of small animals with a triple-head SPECT system using pinhole collimation. Metzler SD; Jaszczak RJ; Patil NH; Vemulapalli S; Akabani G; Chin BB IEEE Trans Med Imaging; 2005 Jul; 24(7):853-62. PubMed ID: 16011314 [TBL] [Abstract][Full Text] [Related]
4. CdZnTe strip detector SPECT imaging with a slit collimator. Zheng GL; Gagnon D Phys Med Biol; 2004 Jun; 49(11):2257-71. PubMed ID: 15248576 [TBL] [Abstract][Full Text] [Related]
5. Development of a pixelated GSO gamma camera system with tungsten parallel hole collimator for single photon imaging. Yamamoto S; Watabe H; Kanai Y; Shimosegawa E; Hatazawa J Med Phys; 2012 Feb; 39(2):581-8. PubMed ID: 22320767 [TBL] [Abstract][Full Text] [Related]
6. A multipinhole small animal SPECT system with submillimeter spatial resolution. Funk T; Després P; Barber WC; Shah KS; Hasegawa BH Med Phys; 2006 May; 33(5):1259-68. PubMed ID: 16752560 [TBL] [Abstract][Full Text] [Related]
7. First results from the high-resolution mouseSPECT annular scintillation camera. Goertzen AL; Jones DW; Seidel J; Li K; Green MV IEEE Trans Med Imaging; 2005 Jul; 24(7):863-7. PubMed ID: 16011315 [TBL] [Abstract][Full Text] [Related]
8. [Development of a high-resolution pinhole SPECT system using dual-head gamma camera for small animal studies]. Yokoi T; Kishi H Kaku Igaku; 1998 Nov; 35(9):901-7. PubMed ID: 9916407 [TBL] [Abstract][Full Text] [Related]
10. Reproducibility of left ventricular volume and ejection fraction measurements in rat using pinhole gated SPECT. Vanhove C; Lahoutte T; Defrise M; Bossuyt A; Franken PR Eur J Nucl Med Mol Imaging; 2005 Feb; 32(2):211-20. PubMed ID: 15372208 [TBL] [Abstract][Full Text] [Related]
11. Pinhole collimation for ultra-high-resolution, small-field-of-view SPECT. Jaszczak RJ; Li J; Wang H; Zalutsky MR; Coleman RE Phys Med Biol; 1994 Mar; 39(3):425-37. PubMed ID: 15551591 [TBL] [Abstract][Full Text] [Related]
12. A new reconstruction strategy for image improvement in pinhole SPECT. Zeniya T; Watabe H; Aoi T; Kim KM; Teramoto N; Hayashi T; Sohlberg A; Kudo H; Iida H Eur J Nucl Med Mol Imaging; 2004 Aug; 31(8):1166-72. PubMed ID: 15029462 [TBL] [Abstract][Full Text] [Related]
13. Design and simulation of a high-resolution stationary SPECT system for small animals. Beekman FJ; Vastenhouw B Phys Med Biol; 2004 Oct; 49(19):4579-92. PubMed ID: 15552418 [TBL] [Abstract][Full Text] [Related]
14. A clinical gamma camera-based pinhole collimated system for high resolution small animal SPECT imaging. Mejia J; Galvis-Alonso OY; Castro AA; Braga J; Leite JP; Simões MV Braz J Med Biol Res; 2010 Dec; 43(12):1160-6. PubMed ID: 21085887 [TBL] [Abstract][Full Text] [Related]
15. Performance analysis of a high-sensitivity multi-pinhole cardiac SPECT system with hemi-ellipsoid detectors. Bhusal N; Dey J; Xu J; Kalluri K; Konik A; Mukherjee JM; Pretorius PH Med Phys; 2019 Jan; 46(1):116-126. PubMed ID: 30407634 [TBL] [Abstract][Full Text] [Related]
16. Design and evaluation of two multi-pinhole collimators for brain SPECT. Chen L; Tsui BMW; Mok GSP Ann Nucl Med; 2017 Oct; 31(8):636-648. PubMed ID: 28755084 [TBL] [Abstract][Full Text] [Related]
17. Development of a variable-radius pinhole SPECT system with a portable gamma camera. Pino F; Roé N; Orero A; Falcón C; Rojas S; Benlloch JM; Ros D; Pavía J Rev Esp Med Nucl; 2011; 30(5):286-91. PubMed ID: 21640439 [TBL] [Abstract][Full Text] [Related]
18. Intrinsic uniformity requirements for pinhole SPECT. Seret A; Bleeser F J Nucl Med Technol; 2006 Mar; 34(1):43-7. PubMed ID: 16517968 [TBL] [Abstract][Full Text] [Related]
19. System design and development of a pinhole SPECT system for quantitative functional imaging of small animals. Aoi T; Zeniya T; Watabe H; Deloar HM; Matsuda T; Iida H Ann Nucl Med; 2006 Apr; 20(3):245-51. PubMed ID: 16715958 [TBL] [Abstract][Full Text] [Related]
20. Three-pinhole collimator to improve axial spatial resolution and sensitivity in pinhole SPECT. Vanhove C; Defrise M; Lahoutte T; Bossuyt A Eur J Nucl Med Mol Imaging; 2008 Feb; 35(2):407-15. PubMed ID: 18000667 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]