These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

173 related articles for article (PubMed ID: 16927220)

  • 1. [Principals and clinical applications of optical coherence tomography in glaucoma].
    Parasta AM; Fabian E; Duncker G
    Klin Monbl Augenheilkd; 2006 Aug; 223(8):656-60. PubMed ID: 16927220
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of optical coherence tomography and heidelberg retinal tomography parameters in detecting early and moderate glaucoma.
    Naithani P; Sihota R; Sony P; Dada T; Gupta V; Kondal D; Pandey RM
    Invest Ophthalmol Vis Sci; 2007 Jul; 48(7):3138-45. PubMed ID: 17591883
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Aligning scan acquisition circles in optical coherence tomography images of the retinal nerve fibre layer.
    Zhu H; Crabb DP; Schlottmann PG; Wollstein G; Garway-Heath DF
    IEEE Trans Med Imaging; 2011 Jun; 30(6):1228-38. PubMed ID: 21296706
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Automatic recovery of the optic nervehead geometry in optical coherence tomography.
    Boyer KL; Herzog A; Roberts C
    IEEE Trans Med Imaging; 2006 May; 25(5):553-70. PubMed ID: 16689260
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Tracking the optic nervehead in OCT video using dual eigenspaces and an adaptive vascular distribution model.
    Koozekanani D; Boyer KL; Roberts C
    IEEE Trans Med Imaging; 2003 Dec; 22(12):1519-36. PubMed ID: 14649743
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparative study of retinal nerve fiber layer thickness in normal eyes, ocular hypertensives, preperimetric glaucoma and glaucomatous subjects.
    Polo V; Larrosa JM; Ferreras A; de la Casa JM; Pablo LE; Honrubia FM
    Ann Ophthalmol (Skokie); 2009; 41(1):24-30. PubMed ID: 19413224
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The role of OCT in glaucoma management.
    Pagliara MM; Lepore D; Balestrazzi E
    Prog Brain Res; 2008; 173():139-48. PubMed ID: 18929106
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The use of optical coherence tomography in neurology.
    Lamirel C; Newman N; Biousse V
    Rev Neurol Dis; 2009; 6(4):E105-20. PubMed ID: 20065921
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Three-dimensional high-speed optical coherence tomography imaging of lamina cribrosa in glaucoma.
    Inoue R; Hangai M; Kotera Y; Nakanishi H; Mori S; Morishita S; Yoshimura N
    Ophthalmology; 2009 Feb; 116(2):214-22. PubMed ID: 19091413
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Retinal atrophy using optical coherence tomography (OCT) in 15 patients with multiple sclerosis and comparison with healthy subjects].
    Jeanjean L; Castelnovo G; Carlander B; Villain M; Mura F; Dupeyron G; Labauge P
    Rev Neurol (Paris); 2008 Nov; 164(11):927-34. PubMed ID: 18808761
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography: a variability and diagnostic performance study.
    Leung CK; Cheung CY; Weinreb RN; Qiu Q; Liu S; Li H; Xu G; Fan N; Huang L; Pang CP; Lam DS
    Ophthalmology; 2009 Jul; 116(7):1257-63, 1263.e1-2. PubMed ID: 19464061
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Longitudinal variability of optic disc and retinal nerve fiber layer measurements.
    Leung CK; Cheung CY; Lin D; Pang CP; Lam DS; Weinreb RN
    Invest Ophthalmol Vis Sci; 2008 Nov; 49(11):4886-92. PubMed ID: 18539940
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In vivo thickness and birefringence determination of the human retinal nerve fiber layer using polarization-sensitive optical coherence tomography.
    Cense B; Chen TC; de Boer JF
    Bull Soc Belge Ophtalmol; 2006; (302):109-21. PubMed ID: 17265793
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of retinal nerve fiber layer thickness measured by Cirrus HD and Stratus optical coherence tomography.
    Sung KR; Kim DY; Park SB; Kook MS
    Ophthalmology; 2009 Jul; 116(7):1264-70, 1270.e1. PubMed ID: 19427696
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Minimum distance mapping using three-dimensional optical coherence tomography for glaucoma diagnosis.
    Povazay B; Hofer B; Hermann B; Unterhuber A; Morgan JE; Glittenberg C; Binder S; Drexler W
    J Biomed Opt; 2007; 12(4):041204. PubMed ID: 17867793
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of retinal nerve fiber layer thickness values using Stratus Optical Coherence Tomography and Heidelberg Retina Tomograph-III.
    Moreno-Montañés J; Antón A; García N; Olmo N; Morilla A; Fallon M
    J Glaucoma; 2009 Sep; 18(7):528-34. PubMed ID: 19745667
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Relationship between retinal nerve fiber layer measurement and signal strength in optical coherence tomography.
    Cheung CY; Leung CK; Lin D; Pang CP; Lam DS
    Ophthalmology; 2008 Aug; 115(8):1347-51, 1351.e1-2. PubMed ID: 18294689
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Correlation between optical coherence tomography and glaucomatous optic nerve head damage in children.
    El-Dairi MA; Holgado S; Asrani SG; Enyedi LB; Freedman SF
    Br J Ophthalmol; 2009 Oct; 93(10):1325-30. PubMed ID: 19028739
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of optic nerve head topography and visual field in eyes with open-angle and angle-closure glaucoma.
    Boland MV; Zhang L; Broman AT; Jampel HD; Quigley HA
    Ophthalmology; 2008 Feb; 115(2):239-245.e2. PubMed ID: 18082888
    [TBL] [Abstract][Full Text] [Related]  

  • 20. New developments in optical coherence tomography for glaucoma.
    Chang R; Budenz DL
    Curr Opin Ophthalmol; 2008 Mar; 19(2):127-35. PubMed ID: 18301286
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.