These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
108 related articles for article (PubMed ID: 16929921)
1. Symmetric sensor for applanation resonance tomometry of the eye. Hallberg P; Lindén C; Bäcklund T; Eklund A Med Biol Eng Comput; 2006 Mar; 44(1-2):54-60. PubMed ID: 16929921 [TBL] [Abstract][Full Text] [Related]
2. Comparison of Goldmann applanation and applanation resonance tonometry in a biomicroscope-based in vitro porcine eye model. Hallberg P; Santala K; Lindén C; Lindahl OA; Eklund A J Med Eng Technol; 2006; 30(6):345-52. PubMed ID: 17060162 [TBL] [Abstract][Full Text] [Related]
3. An applanation resonator sensor for measuring intraocular pressure using combined continuous force and area measurement. Eklund A; Hallberg P; Lindén C; Lindahl OA Invest Ophthalmol Vis Sci; 2003 Jul; 44(7):3017-24. PubMed ID: 12824247 [TBL] [Abstract][Full Text] [Related]
4. A resonator sensor for measurement of intraocular pressure--evaluation in an in vitro pig-eye model. Eklund A; Bäcklund T; Lindahl OA Physiol Meas; 2000 Aug; 21(3):355-67. PubMed ID: 10984204 [TBL] [Abstract][Full Text] [Related]
5. Clinical evaluation of applanation resonance tonometry: a comparison with Goldmann applanation tonometry. Hallberg P; Eklund A; Bäcklund T; Lindén C J Glaucoma; 2007 Jan; 16(1):88-93. PubMed ID: 17224756 [TBL] [Abstract][Full Text] [Related]
6. [Validity and reproducibility of sensor contact lens profiles in comparison to applanation tonometry in healthy eyes]. Faschinger C; Mossböck G; Krainz S Klin Monbl Augenheilkd; 2012 Dec; 229(12):1209-14. PubMed ID: 23172649 [TBL] [Abstract][Full Text] [Related]
7. [How does central cornea thickness influence intraocular pressure during applanation and contour tonometry?]. Schwenteck T; Knappe M; Moros I Klin Monbl Augenheilkd; 2012 Sep; 229(9):917-27. PubMed ID: 22972357 [TBL] [Abstract][Full Text] [Related]
8. The accuracy of continued clinical use of goldmann applanation tonometers with known calibration errors. Sandhu SS; Chattopadhyay S; Amariotakis GA; Skarmoutsos F; Birch MK; Ray-Chaudhuri N Ophthalmology; 2009 Jan; 116(1):9-13. PubMed ID: 18801579 [TBL] [Abstract][Full Text] [Related]
9. Evaluation of applanation resonator sensors for intra-ocular pressure measurement: results from clinical and in vitro studies. Eklund A; Lindén C; Bäcklund T; Andersson BM; Lindahl OA Med Biol Eng Comput; 2003 Mar; 41(2):190-7. PubMed ID: 12691439 [TBL] [Abstract][Full Text] [Related]
10. Clinical comparison of the TonoVet(®) rebound tonometer and the Tono-Pen Vet(®) applanation tonometer in dogs and cats with ocular disease: glaucoma or corneal pathology. von Spiessen L; Karck J; Rohn K; Meyer-Lindenberg A Vet Ophthalmol; 2015 Jan; 18(1):20-7. PubMed ID: 24131625 [TBL] [Abstract][Full Text] [Related]
11. Investigation of intraocular pressure of the anterior chamber and vitreous cavity of porcine eyes via a novel method. Nagae K; Sawamura H; Aihara M Sci Rep; 2020 Nov; 10(1):20552. PubMed ID: 33239714 [TBL] [Abstract][Full Text] [Related]
12. Implantation of a novel telemetric intraocular pressure sensor in patients with glaucoma (ARGOS study): 1-year results. Koutsonas A; Walter P; Roessler G; Plange N Invest Ophthalmol Vis Sci; 2015 Jan; 56(2):1063-9. PubMed ID: 25613949 [TBL] [Abstract][Full Text] [Related]
13. Development of a completely encapsulated intraocular pressure sensor. Walter P; Schnakenberg U; vom Bögel G; Ruokonen P; Krüger C; Dinslage S; Lüdtke Handjery HC; Richter H; Mokwa W; Diestelhorst M; Krieglstein GK Ophthalmic Res; 2000; 32(6):278-84. PubMed ID: 11015039 [TBL] [Abstract][Full Text] [Related]
14. Effects of topical anaesthetics and repeated tonometry on intraocular pressure. Jóhannesson G; Hallberg P; Eklund A; Behndig A; Lindén C Acta Ophthalmol; 2014 Mar; 92(2):111-5. PubMed ID: 23387522 [TBL] [Abstract][Full Text] [Related]
15. Measurement of the intraocular pressure with the "transpalpebral tonometer" TGDc-01 in comparison with applanation tonometry. Sandner D; Böhm A; Kostov S; Pillunat L Graefes Arch Clin Exp Ophthalmol; 2005 Jun; 243(6):563-9. PubMed ID: 15614540 [TBL] [Abstract][Full Text] [Related]
16. Introduction and clinical evaluation of servo-controlled applanation resonance tonometry. Jóhannesson G; Hallberg P; Eklund A; Lindén C Acta Ophthalmol; 2012 Nov; 90(7):677-82. PubMed ID: 21323868 [TBL] [Abstract][Full Text] [Related]
17. Soft wearable contact lens sensor for continuous intraocular pressure monitoring. Chen GZ; Chan IS; Leung LK; Lam DC Med Eng Phys; 2014 Sep; 36(9):1134-9. PubMed ID: 25034639 [TBL] [Abstract][Full Text] [Related]
18. Deviations between transpalpebral tonometry using TGDc-01 and Goldmann applanation tonometry depending on the IOP level. Troost A; Specht K; Krummenauer F; Yun SH; Schwenn O Graefes Arch Clin Exp Ophthalmol; 2005 Sep; 243(9):853-8. PubMed ID: 16158308 [TBL] [Abstract][Full Text] [Related]
19. Performance of the rebound, noncontact and Goldmann applanation tonometers in routine clinical practice. Martinez-de-la-Casa JM; Jimenez-Santos M; Saenz-Frances F; Matilla-Rodero M; Mendez-Hernandez C; Herrero-Vanrell R; Garcia-Feijoo J Acta Ophthalmol; 2011 Nov; 89(7):676-80. PubMed ID: 19900196 [TBL] [Abstract][Full Text] [Related]
20. [Applanation tonometry in "normal" patients and patients after LASIK]. Kohlhaas M; Spörl E; Böhm AG; Pollack K; Sandner D; Pillunat LE Klin Monbl Augenheilkd; 2005 Oct; 222(10):823-6. PubMed ID: 16240277 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]