These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

61 related articles for article (PubMed ID: 16939920)

  • 1. [Finite element analysis of a new shape memory alloy cervical hook for atlantoaxial instability].
    Shu XQ; Wan L; Yu CT; Yin T; Jin AM
    Nan Fang Yi Ke Da Xue Xue Bao; 2006 Aug; 26(8):1197-9. PubMed ID: 16939920
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Finite element analysis of shape memory alloy intrasegmental fixator for lumbar spondylolysis].
    Zhang H; Jin AM; Zhang MC
    Di Yi Jun Yi Da Xue Xue Bao; 2002 Dec; 22(12):1128-30. PubMed ID: 12480595
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Atlantoaxial instability.
    Goel A
    J Neurosurg Spine; 2004 Oct; 1(3):347; author reply 347. PubMed ID: 15478375
    [No Abstract]   [Full Text] [Related]  

  • 4. A shape memory alloy implant can be an effective surgical treatment in the atlantoaxial joint stabilization using rabbits as substitutes for toy-breed dogs.
    Seon Y; Choi SK; Kim WK; Kang BJ
    Am J Vet Res; 2023 Nov; 84(11):. PubMed ID: 37591491
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Biomechanical performance of different wires and cable fixation devices in posterior instrumentation for atlantoaxial instability].
    Liu TL; Yan WJ; Han Y; Ye XJ; Jia LS; Li JS; Yuan W
    Nan Fang Yi Ke Da Xue Xue Bao; 2010 May; 30(5):1127-31. PubMed ID: 20501411
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Internal fixation for atlanto-axial instability in children.
    Flint GA; Hockley AD
    Childs Nerv Syst; 1987; 3(6):368-70. PubMed ID: 3450388
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Role of transarticular screw fixation in tuberculous atlanto-axial instability.
    Bapat MR; Lahiri VJ; Harshavardhan NS; Metkar US; Chaudhary KC
    Eur Spine J; 2007 Feb; 16(2):187-97. PubMed ID: 16482454
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Atlantoaxial stabilization with the use of C1-3 lateral mass screw fixation. Technical note.
    Horn EM; Hott JS; Porter RW; Theodore N; Papadopoulos SM; Sonntag VK
    J Neurosurg Spine; 2006 Aug; 5(2):172-7. PubMed ID: 16925087
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Treatment of upper cervical spine instability with posterior fusion plus atlantoaxial pedicle screw].
    Ma C; Wu JB; Zhao M; Dai WX; Wu DH; Wang ZH; Feng J; Liu C; Zhao QH; Tian JW
    Zhonghua Yi Xue Za Zhi; 2011 Nov; 91(43):3062-5. PubMed ID: 22333060
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Atlantoaxial fixation using plate and screw method: a report of 160 treated patients.
    Goel A; Desai KI; Muzumdar DP
    Neurosurgery; 2002 Dec; 51(6):1351-6; discussion 1356-7. PubMed ID: 12445339
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Clinical effect of posterior atlanto axial vertebra internal fixation for treatment of instability of occipitocervical].
    Zhang QH; Chen QX; Li FC; Chen G; Han B
    Zhongguo Gu Shang; 2013 Jun; 26(6):493-6. PubMed ID: 24015655
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Stereotactic atlantoaxial transarticular screw fixation.
    Laherty RW; Kahler RJ; Walker DG; Tomlinson FH
    J Clin Neurosci; 2005 Jan; 12(1):62-5. PubMed ID: 15639416
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Biomechanical study of atlantoaxial fixation for transverse ligament injury leading to atlantoaxial instability].
    Tian JW; Wang Z; Zhao QH; Wang L; Dong SH; Xia T; Liu CY
    Zhonghua Yi Xue Za Zhi; 2012 May; 92(17):1198-200. PubMed ID: 22883010
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Anti-rotation biomechanical study of wire and various cable system in the posterior brooks instrumentation for atlantoaxial instability].
    Liu TL; Zhang YZ; Yan WJ; Li JS; Yuan W
    Zhongguo Gu Shang; 2008 Aug; 21(8):570-2. PubMed ID: 19108363
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical assessment of bilateral C1 laminar hook and C1-2 transarticular screws and bone graft for atlantoaxial instability.
    Guo X; Ni B; Zhao W; Wang M; Zhou F; Li S; Ren Z
    J Spinal Disord Tech; 2009 Dec; 22(8):578-85. PubMed ID: 19956032
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biomechanical study of artificial atlanto-odontoid joint.
    Lu B; He X; Zhao CG; Li HP; Wang D
    Spine (Phila Pa 1976); 2009 Aug; 34(18):1893-9. PubMed ID: 19680097
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Images in spine surgery: atlantoaxial instability in Down syndrome.
    Riaz S; Drake JM; Hedden DM
    J Pak Med Assoc; 2007 Apr; 57(4):213-5. PubMed ID: 17489535
    [No Abstract]   [Full Text] [Related]  

  • 18. Clinical outcome of posterior fixation of the C1 lateral mass and C2 pedicle by polyaxial screw and rod.
    Jeon SW; Jeong JH; Choi GH; Moon SM; Hwang HS; Choi SK
    Clin Neurol Neurosurg; 2012 Jul; 114(6):539-44. PubMed ID: 22130046
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Atlantoaxial transarticular screw fixation with morselized autograft and without additional internal fixation: technical description and report of 57 cases.
    Wang C; Yan M; Zhou H; Wang S; Dang G
    Spine (Phila Pa 1976); 2007 Mar; 32(6):643-6. PubMed ID: 17413468
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Atlantoaxial instability in Down's syndrome: clinical and radiological screening.
    Cullen S; O'Connell E; Blake NS; Ward OC
    Ir Med J; 1989 Jun; 82(2):64-5. PubMed ID: 2527213
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.