These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
22. Using hemolyzed specimens. Alter D; Sykes E Am J Clin Pathol; 2000 Nov; 114(5):820-1. PubMed ID: 11068559 [No Abstract] [Full Text] [Related]
23. Randomized, single blinded control trial comparing haemolysis rate between two cannula aspiration techniques. Dwyer DG; Fry M; Somerville A; Holdgate A Emerg Med Australas; 2006; 18(5-6):484-8. PubMed ID: 17083638 [TBL] [Abstract][Full Text] [Related]
24. [Blood specimen collection should be performed by qualifies personnel]. Viddal BV Tidsskr Nor Laegeforen; 2008 Nov; 128(21):2472. PubMed ID: 19096473 [No Abstract] [Full Text] [Related]
25. [Numerous factors and incorrect measurements can lead to misinterpretations. Be critical when dealing with hormone levels]. Bidlingmaier M MMW Fortschr Med; 2009 Oct; 151(42):36. PubMed ID: 19938778 [No Abstract] [Full Text] [Related]
26. Fainting and hemolysis during blood sampling in youngsters: prevalence study. Vissers D; Matthyssen B; Truijen S; Blommaert S; Van De Velde K; Van Gaal L Int J Nurs Stud; 2008 May; 45(5):760-4. PubMed ID: 17331515 [TBL] [Abstract][Full Text] [Related]
27. [Effects of anticoagulants used at blood specimen collection on clinical test results]. Narayanan S Rinsho Byori; 1996 Nov; Suppl 103():73-91. PubMed ID: 9190426 [No Abstract] [Full Text] [Related]
28. Stability of coagulation assays performed in plasma from citrated whole blood transported at ambient temperature. Zürcher M; Sulzer I; Barizzi G; Lämmle B; Alberio L Thromb Haemost; 2008 Feb; 99(2):416-26. PubMed ID: 18278194 [TBL] [Abstract][Full Text] [Related]
31. [Blood specimen sending by pneumatic tube mail functions well!]. Eggen BM; Normann EK; Frøystein KV Tidsskr Nor Laegeforen; 2009 Mar; 129(6):541. PubMed ID: 19282897 [No Abstract] [Full Text] [Related]
32. Those new tests they're doing. Boyd PR; Martin BG; Brown DM RN; 1980 Feb; 43(2):43-8. PubMed ID: 6987720 [No Abstract] [Full Text] [Related]
33. An automated method for the measurement of methaemoglobin in avian blood. Martínez-Haro M; Mateo R Vet J; 2008 Jun; 176(3):405-7. PubMed ID: 17452116 [TBL] [Abstract][Full Text] [Related]
34. Variations in serum glucose, urea, creatinine and sodium and potassium as a consequence of delayed transport/processing of samples and delay in assays. Joshi AR JNMA J Nepal Med Assoc; 2006; 45(161):186-9. PubMed ID: 17160095 [TBL] [Abstract][Full Text] [Related]
35. Dried blood spot methods in therapeutic drug monitoring: methods, assays, and pitfalls. Edelbroek PM; van der Heijden J; Stolk LM Ther Drug Monit; 2009 Jun; 31(3):327-36. PubMed ID: 19349929 [TBL] [Abstract][Full Text] [Related]
36. [Interference in the creatine kinase assay: the "wave" phenomenon]. Cohen S Ann Biol Clin (Paris); 2003; 61(3):328-31. PubMed ID: 12805011 [No Abstract] [Full Text] [Related]
37. Perspectives and advances in in-clinic laboratory diagnostic capabilities: hematology and clinical chemistry. Weiser MG; Vap LM; Thrall MA Vet Clin North Am Small Anim Pract; 2007 Mar; 37(2):221-36, v. PubMed ID: 17336672 [TBL] [Abstract][Full Text] [Related]
38. In vitro quality of red blood cells (RBCs) collected by multicomponent apheresis compared to manually collected RBCs during 49 days of storage. Picker SM; Radojska SM; Gathof BS Transfusion; 2007 Apr; 47(4):687-96. PubMed ID: 17381628 [TBL] [Abstract][Full Text] [Related]