These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Gestational age at birth affects maturation of baroreflex control. Fyfe KL; Yiallourou SR; Wong FY; Odoi A; Walker AM; Horne RS J Pediatr; 2015 Mar; 166(3):559-65. PubMed ID: 25556016 [TBL] [Abstract][Full Text] [Related]
5. The CNAP™ Finger Cuff for Noninvasive Beat-To-Beat Monitoring of Arterial Blood Pressure: An Evaluation in Intensive Care Unit Patients and a Comparison with 2 Intermittent Devices. Lakhal K; Martin M; Faiz S; Ehrmann S; Blanloeil Y; Asehnoune K; Rozec B; Boulain T Anesth Analg; 2016 Nov; 123(5):1126-1135. PubMed ID: 27159068 [TBL] [Abstract][Full Text] [Related]
7. Autonomic cardiovascular control in hypotensive critically ill preterm infants is impaired during the first days of life. Golder V; Hepponstall M; Yiallourou SR; Odoi A; Horne RS Early Hum Dev; 2013 Jun; 89(6):419-23. PubMed ID: 23313567 [TBL] [Abstract][Full Text] [Related]
8. Baroreflex sensitivity and blood pressure in premature infants - dependence on gestational age, postnatal age and sex. Javorka K; Hašková K; Czippelová B; Zibolen M; Javorka M Physiol Res; 2021 Dec; 70(S3):S349-S356. PubMed ID: 35099253 [TBL] [Abstract][Full Text] [Related]
9. Noninvasive measurement of blood pressure variability: accuracy of the Finometer monitor and comparison with the Finapres device. Maestri R; Pinna GD; Robbi E; Capomolla S; La Rovere MT Physiol Meas; 2005 Dec; 26(6):1125-36. PubMed ID: 16311459 [TBL] [Abstract][Full Text] [Related]
14. The Accuracy of the CNAP® Device Compared with Invasive Radial Artery Measurements for Providing Continuous Noninvasive Arterial Blood Pressure Readings at a Medical Intensive Care Unit: A Method-Comparison Study. Smolle KH; Schmid M; Prettenthaler H; Weger C Anesth Analg; 2015 Dec; 121(6):1508-16. PubMed ID: 26496367 [TBL] [Abstract][Full Text] [Related]
15. Relation of heart rate and blood pressure turbulence following premature ventricular complexes to baroreflex sensitivity in chronic congestive heart failure. Davies LC; Francis DP; Ponikowski P; Piepoli MF; Coats AJ Am J Cardiol; 2001 Mar; 87(6):737-42. PubMed ID: 11249893 [TBL] [Abstract][Full Text] [Related]
16. Comparing volume-clamp method and intra-arterial blood pressure measurements in patients with atrial fibrillation admitted to the intensive or medium care unit. Berkelmans GFN; Kuipers S; Westerhof BE; Spoelstra-de Man AME; Smulders YM J Clin Monit Comput; 2018 Jun; 32(3):439-446. PubMed ID: 28688009 [TBL] [Abstract][Full Text] [Related]
17. Comparison of upper arm and calf oscillometric blood pressure measurement in preterm infants. Kunk R; McCain GC J Perinatol; 1996; 16(2 Pt 1):89-92. PubMed ID: 8732553 [TBL] [Abstract][Full Text] [Related]
18. Are baroreflex events detected by invasive and non-invasive techniques coincident? Smith SM; Potter JF; Samani NJ; Sammons EL; Rathbone WE; Bentley S; Panerai RB Clin Physiol Funct Imaging; 2008 Jul; 28(4):262-9. PubMed ID: 18384622 [TBL] [Abstract][Full Text] [Related]
19. Feasibility of noninvasive continuous finger arterial blood pressure measurements in very young children, aged 0-4 years. Andriessen P; Schraa O; van Den Bosch-Ruis W; Jan Ten Harkel D; Settels JJ; Oetomo SB; Blanco CE Pediatr Res; 2008 Jun; 63(6):691-6. PubMed ID: 18520333 [TBL] [Abstract][Full Text] [Related]
20. Comparison of Invasive Arterial Blood Pressure Monitoring vs. Non-Invasive Blood Pressure Monitoring in Preterm Infants < 37 Weeks in the Neonatal Intensive Care Unit- A Prospective Observational Study. Shah S; Kaul A; Khandare J; Dhalait S J Trop Pediatr; 2021 Dec; 67(6):. PubMed ID: 34966946 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]