These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

179 related articles for article (PubMed ID: 16953044)

  • 21. [Assessment of the solid-liquid behavior of the liver for the diagnosis of diffuse disease using magnetic resonance elastography].
    Klatt D; Asbach P; Somasundaram R; Hamm B; Braun J; Sack I
    Rofo; 2008 Dec; 180(12):1104-9. PubMed ID: 18814103
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Contrast-transfer improvement for electrode displacement elastography.
    Bharat S; Varghese T
    Phys Med Biol; 2006 Dec; 51(24):6403-18. PubMed ID: 17148825
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The influence of the boundary conditions on longitudinal wave propagation in a viscoelastic medium.
    Eskandari H; Baghani A; Salcudean SE; Rohling R
    Phys Med Biol; 2009 Jul; 54(13):3997-4017. PubMed ID: 19502703
    [TBL] [Abstract][Full Text] [Related]  

  • 24. An inverse problem solution for measuring the elastic modulus of intact ex vivo breast tissue tumours.
    Samani A; Plewes D
    Phys Med Biol; 2007 Mar; 52(5):1247-60. PubMed ID: 17301452
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The natural frequencies of microbubble oscillation in elastic vessels.
    Martynov S; Stride E; Saffari N
    J Acoust Soc Am; 2009 Dec; 126(6):2963-72. PubMed ID: 20000909
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Harmonic pulsed excitation and motion detection of a vibrating reflective target.
    Urban MW; Greenleaf JF
    J Acoust Soc Am; 2008 Jan; 123(1):519-33. PubMed ID: 18177179
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Acoustic scattering from a contrast agent microbubble near an elastic wall of finite thickness.
    Doinikov AA; Aired L; Bouakaz A
    Phys Med Biol; 2011 Nov; 56(21):6951-67. PubMed ID: 22008736
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Copolymer-in-oil phantom materials for elastography.
    Oudry J; Bastard C; Miette V; Willinger R; Sandrin L
    Ultrasound Med Biol; 2009 Jul; 35(7):1185-97. PubMed ID: 19427100
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The high frequency properties of brain tissue.
    Lippert SA; Rang EM; Grimm MJ
    Biorheology; 2004; 41(6):681-91. PubMed ID: 15851844
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Three-dimensional finite element simulations of the dynamic response of a fingertip to vibration.
    Wu JZ; Krajnak K; Welcome DE; Dong RG
    J Biomech Eng; 2008 Oct; 130(5):054501. PubMed ID: 19045525
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Mechanical characterization of atherosclerotic arteries using finite-element modeling: feasibility study on mock arteries.
    Pazos V; Mongrain R; Tardif JC
    IEEE Trans Biomed Eng; 2010 Jun; 57(6):1520-8. PubMed ID: 20172784
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The biomechanics of human femurs in axial and torsional loading: comparison of finite element analysis, human cadaveric femurs, and synthetic femurs.
    Papini M; Zdero R; Schemitsch EH; Zalzal P
    J Biomech Eng; 2007 Feb; 129(1):12-9. PubMed ID: 17227093
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Ultrasound bladder vibrometry method for measuring viscoelasticity of the bladder wall.
    Nenadic IZ; Qiang B; Urban MW; de Araujo Vasconcelo LH; Nabavizadeh A; Alizad A; Greenleaf JF; Fatemi M
    Phys Med Biol; 2013 Apr; 58(8):2675-95. PubMed ID: 23552842
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The viscoelastic standard nonlinear solid model: predicting the response of the lumbar intervertebral disk to low-frequency vibrations.
    Groth KM; Granata KP
    J Biomech Eng; 2008 Jun; 130(3):031005. PubMed ID: 18532854
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Modified Bilston nonlinear viscoelastic model for finite element head injury studies.
    Shen F; Tay TE; Li JZ; Nigen S; Lee PV; Chan HK
    J Biomech Eng; 2006 Oct; 128(5):797-801. PubMed ID: 16995770
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Analysis of contrast in images generated with transient acoustic radiation force.
    Nightingale K; Palmeri M; Trahey G
    Ultrasound Med Biol; 2006 Jan; 32(1):61-72. PubMed ID: 16364798
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Modeling soft-tissue deformation prior to cutting for surgical simulation: finite element analysis and study of cutting parameters.
    Chanthasopeephan T; Desai JP; Lau AC
    IEEE Trans Biomed Eng; 2007 Mar; 54(3):349-59. PubMed ID: 17355046
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Parametric finite element analysis of physical stimuli resulting from mechanical stimulation of tissue engineered cartilage.
    Babalola OM; Bonassar LJ
    J Biomech Eng; 2009 Jun; 131(6):061014. PubMed ID: 19449968
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Quantitative analysis of liver fibrosis in rats with shearwave dispersion ultrasound vibrometry: comparison with dynamic mechanical analysis.
    Zhu Y; Zhang X; Zheng Y; Chen X; Shen Y; Lin H; Guo Y; Wang T; Chen S
    Med Eng Phys; 2014 Nov; 36(11):1401-7. PubMed ID: 24835187
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Individual and collective vibrational modes of nanostructures studied by picosecond ultrasonics.
    Bienville T; Robillard JF; Belliard L; Roch-Jeune I; Devos A; Perrin B
    Ultrasonics; 2006 Dec; 44 Suppl 1():e1289-94. PubMed ID: 16806353
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.