21. Inconsistencies in endoscope-reprocessing and infection-control guidelines: the importance of endoscope drying.
Muscarella LF
Am J Gastroenterol; 2006 Sep; 101(9):2147-54. PubMed ID: 16968511
[TBL] [Abstract][Full Text] [Related]
22. A novel automated waterline cleaning system that facilitates effective and consistent control of microbial biofilm contamination of dental chair unit waterlines: a one-year study.
O'Donnell MJ; Shore AC; Coleman DC
J Dent; 2006 Oct; 34(9):648-61. PubMed ID: 16442201
[TBL] [Abstract][Full Text] [Related]
23. Effectiveness of bacterial disinfectants on surfaces of mechanical ventilator systems.
Sui YS; Wan GH; Chen YW; Ku HL; Li LP; Liu CH; Mau HS
Respir Care; 2012 Feb; 57(2):250-6. PubMed ID: 21762555
[TBL] [Abstract][Full Text] [Related]
24. [Survey of methods of cleaning, decontamination, disinfection and sterilization in dental health services in tropical areas].
Clapeau G; Decroix B; Bakayoko-Ly R; Varenne B; Dosso-Hien D; Decroix MO
Sante; 1997; 7(5):323-9. PubMed ID: 9480039
[TBL] [Abstract][Full Text] [Related]
25. [A study on bacterial contamination of dental handpieces].
Hu T; Meng X; Zuo Y; zhou X
Hua Xi Kou Qiang Yi Xue Za Zhi; 2001 Apr; 19(2):93-4, 98. PubMed ID: 12539420
[TBL] [Abstract][Full Text] [Related]
26. An investigation of the decontamination of Siqveland matrix bands.
Whitworth CL; Davies K; Palmer NO; Martin MV
Br Dent J; 2007 Feb; 202(4):E12; discussion 220-1. PubMed ID: 17308532
[TBL] [Abstract][Full Text] [Related]
27. [Residual bacterial contamination of rhinoscopes used in ENT consultation after cleaning with a pad impregnated with a disinfectant].
Kutter J; Blanc D; Lang FJ
Schweiz Med Wochenschr; 2000; Suppl 125():48S-51S. PubMed ID: 11141939
[TBL] [Abstract][Full Text] [Related]
28. Cleaning dental instruments: measuring the effectiveness of an instrument washer/disinfector.
Miller CH; Tan CM; Beiswanger MA; Gaines DJ; Setcos JC; Palenik CJ
Am J Dent; 2000 Feb; 13(1):39-43. PubMed ID: 11763901
[TBL] [Abstract][Full Text] [Related]
29. [Ultrasound guided regional anaesthesia: an effective method for cleaning the probes].
Bloc S; Garnier T; Bounhiol C; Komly B; Machado G; Leclerc P; Roy M; Mercadal L; Demontoux V; Morel B; Ecoffey C; Dhonneur G
Ann Fr Anesth Reanim; 2008 Dec; 27(12):994-8. PubMed ID: 19026515
[TBL] [Abstract][Full Text] [Related]
30. New disinfectants.
Podstatová H; Melichercíková V; Kneiflová J; Paríková J
Acta Univ Palacki Olomuc Fac Med; 1991; 130():341-51. PubMed ID: 1838887
[TBL] [Abstract][Full Text] [Related]
31. Evaluation of otoscope cone disinfection techniques and contamination level in small animal private practice.
Kirby AL; Rosenkrantz WS; Ghubash RM; Neradilek B; Polissar NL
Vet Dermatol; 2010 Apr; 21(2):175-83. PubMed ID: 20230588
[TBL] [Abstract][Full Text] [Related]
32. Antimicrobial spray for toothbrush disinfection: an in vivo evaluation.
Sato S; Pedrazzi V; Guimarães Lara EH; Panzeri H; Ferreira de Albuquerque R; Ito IY
Quintessence Int; 2005; 36(10):812-6. PubMed ID: 16261797
[TBL] [Abstract][Full Text] [Related]
33. Controlling bacterial contamination of dental impression guns.
Westergard EJ; Romito LM; Kowolik MJ; Palenik CJ
J Am Dent Assoc; 2011 Nov; 142(11):1269-74. PubMed ID: 22041413
[TBL] [Abstract][Full Text] [Related]
34. [Hygienic processing of dental transmission instruments (handpieces and instruments, turbines) in dental practice].
Gräf W; Kunz B; Loisl B
Zentralbl Hyg Umweltmed; 1995 Oct; 198(1):72-83. PubMed ID: 9409896
[TBL] [Abstract][Full Text] [Related]
35. A comparison of decontamination methods used for dental burs.
Whitworth CL; Martin MV; Gallagher M; Worthington HV
Br Dent J; 2004 Nov; 197(10):635-40; discussion 623. PubMed ID: 15611751
[TBL] [Abstract][Full Text] [Related]
36. Soft contact lens disinfection solution efficacy: clinical Fusarium isolates vs. ATCC 36031.
Hume EB; Flanagan J; Masoudi S; Zhu H; Cole N; Willcox MD
Optom Vis Sci; 2009 May; 86(5):415-9. PubMed ID: 19384259
[TBL] [Abstract][Full Text] [Related]
37. Evaluation of ultraviolet C for disinfection of endocavitary ultrasound transducers persistently contaminated despite probe covers.
Kac G; Podglajen I; Si-Mohamed A; Rodi A; Grataloup C; Meyer G
Infect Control Hosp Epidemiol; 2010 Feb; 31(2):165-70. PubMed ID: 20025531
[TBL] [Abstract][Full Text] [Related]
38. Select proper germicides for clinical tasks.
Lado E; Grimaudo NJ
Todays FDA; 2002 Nov; 14(11):20-5. PubMed ID: 12510603
[No Abstract] [Full Text] [Related]
39. Disinfection efficiency of irreversible hydrocolloid impressions using different concentrations of sodium hypochlorite: a pilot study.
Memarian M; Fazeli MR; Jamalifar H; Azimnejad A
J Contemp Dent Pract; 2007 May; 8(4):27-34. PubMed ID: 17486184
[TBL] [Abstract][Full Text] [Related]
40. Disinfection of irreversible hydrocolloid impressions: a comparative study.
McNeill MR; Coulter WA; Hussey DL
Int J Prosthodont; 1992; 5(6):563-7. PubMed ID: 1339136
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]