These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

106 related articles for article (PubMed ID: 16957669)

  • 21. Feasibility of using intermediate x-ray energies for highly conformal extracranial radiotherapy.
    Dong P; Yu V; Nguyen D; Demarco J; Woods K; Boucher S; Low DA; Sheng K
    Med Phys; 2014 Apr; 41(4):041709. PubMed ID: 24694129
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The spectrum and angular distribution of x rays scattered from a water phantom.
    Cheng CW; Taylor KW; Holloway AF
    Med Phys; 1995 Aug; 22(8):1235-45. PubMed ID: 7476709
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Monte Carlo characterization of skin doses in 6 MV transverse field MRI-linac systems: effect of field size, surface orientation, magnetic field strength, and exit bolus.
    Oborn BM; Metcalfe PE; Butson MJ; Rosenfeld AB
    Med Phys; 2010 Oct; 37(10):5208-17. PubMed ID: 21089754
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Estimation of the dose at the maze entrance for x-rays from radiotherapy linear accelerators.
    Al-Affan IA
    Med Phys; 2000 Jan; 27(1):231-8. PubMed ID: 10659762
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Investigations of different kilovoltage X-ray energy for three-dimensional converging stereotactic radiotherapy system: Monte Carlo simulations with CT data.
    Deloar HM; Kunieda E; Kawase T; Tsunoo T; Saitoh H; Ozaki M; Saito K; Takagi S; Sato O; Fujisaki T; Myojoyama A; Sorell G
    Med Phys; 2006 Dec; 33(12):4635-42. PubMed ID: 17278816
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Irradiation of gold nanoparticles by x-rays: Monte Carlo simulation of dose enhancements and the spatial properties of the secondary electrons production.
    Leung MK; Chow JC; Chithrani BD; Lee MJ; Oms B; Jaffray DA
    Med Phys; 2011 Feb; 38(2):624-31. PubMed ID: 21452700
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Evaluation of the contribution of capture gamma rays, x-ray leakage, and scatter to the photon dose at the maze door for a high energy medical electron accelerator using a Monte Carlo particle transport code.
    McGinley PH; Dhaba'an AH; Reft CS
    Med Phys; 2000 Jan; 27(1):225-30. PubMed ID: 10659761
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A systematic evaluation of air cavity dose perturbation in megavoltage x-ray beams.
    Li XA; Yu C; Holmes T
    Med Phys; 2000 May; 27(5):1011-7. PubMed ID: 10841404
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Experimental measurement of radiological penumbra associated with intermediate energy x-rays (1 MV) and small radiosurgery field sizes.
    Keller BM; Beachey DJ; Pignol JP
    Med Phys; 2007 Oct; 34(10):3996-4002. PubMed ID: 17985645
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Scattered fractions of dose from 6,10,18, and 25 MV linear accelerator x rays in radiotherapy facilities.
    Shobe J; Rodgers JE; Taylor PL
    Health Phys; 1999 Jan; 76(1):27-35. PubMed ID: 9883944
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Measured and Monte Carlo simulated surface dose reduction for superficial X-rays incident on tissue with underlying air or bone.
    Baines J; Zawlodzka S; Markwell T; Chan M
    Med Phys; 2018 Feb; 45(2):926-933. PubMed ID: 29235131
    [TBL] [Abstract][Full Text] [Related]  

  • 32. An experimental and Monte Carlo investigation of the energy dependence of alanine/EPR dosimetry: I. Clinical x-ray beams.
    Zeng GG; McEwen MR; Rogers DW; Klassen NV
    Phys Med Biol; 2004 Jan; 49(2):257-70. PubMed ID: 15083670
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Accounting for primary electron scatter in x-ray beam convolution calculations.
    Keall P; Hoban P
    Med Phys; 1995 Sep; 22(9):1413-8. PubMed ID: 8531866
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Surface dosimetry for oblique tangential photon beams: a Monte Carlo simulation study.
    Chow JC; Grigorov GN
    Med Phys; 2008 Jan; 35(1):70-6. PubMed ID: 18293563
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Total Ambient Dose Equivalent Buildup Factors for Portland Concrete.
    Duckic P; Hayes RB
    Health Phys; 2018 Sep; 115(3):324-337. PubMed ID: 30045112
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Are neutrons responsible for the dose discrepancies between Monte Carlo calculations and measurements in the build-up region for a high-energy photon beam?
    Ding GX; Duzenli C; Kalach NI
    Phys Med Biol; 2002 Sep; 47(17):3251-61. PubMed ID: 12361221
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Dose enhancement in gold nanoparticle-aided radiotherapy for the therapeutic photon beams using Monte Carlo technique.
    Kakade NR; Sharma SD
    J Cancer Res Ther; 2015; 11(1):94-7. PubMed ID: 25879344
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Monte Carlo simulations of a kilovoltage external beam radiotherapy system on phantoms and breast patients.
    Breitkreutz DY; Weil MD; Zavgorodni S; Bazalova-Carter M
    Med Phys; 2017 Dec; 44(12):6548-6559. PubMed ID: 28986987
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Validation of Monte Carlo calculated surface doses for megavoltage photon beams.
    Abdel-Rahman W; Seuntjens JP; Verhaegen F; Deblois F; Podgorsak EB
    Med Phys; 2005 Jan; 32(1):286-98. PubMed ID: 15719980
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Wedge design and dosimetry for 25-MV x rays.
    Abrath FG; Purdy JA
    Radiology; 1980 Sep; 136(3):757-62. PubMed ID: 6773106
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.