BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

103 related articles for article (PubMed ID: 16957915)

  • 21. Comparison of two high-performance liquid chromatographic methods for monitoring plasma concentrations of haloperidol and reduced haloperidol.
    Pan L; Rosseel MT; Belpaire FM
    Ther Drug Monit; 1998 Apr; 20(2):224-30. PubMed ID: 9558139
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The measurement of haloperidol and reduced haloperidol in neonatal hair as an index of placental transfer of maternal haloperidol.
    Uematsu T; Yamada K; Matsuno H; Nakashima M
    Ther Drug Monit; 1991 Mar; 13(2):183-7. PubMed ID: 2053128
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Determination of haloperidol and hydroxy haloperidol in human plasma by high performance liquid chromatography.
    Pommery J; Foulon O; Morineau G; Lhermitte M; Levron JC; Erb F
    Ann Biol Clin (Paris); 1990; 48(7):455-8. PubMed ID: 2278409
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Possible interference by the reduced haloperidol metabolite with the radioimmunoassay and radioreceptor assay of blood haloperidol.
    Korpi ER; Ko GN; Phelps BH; Wyatt RJ
    J Clin Psychopharmacol; 1984 Dec; 4(6):332-5. PubMed ID: 6512001
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Chirality of reduced haloperidol in humans.
    Eyles DW; McGrath JJ; Stedman TJ; Pond SM
    Eur Neuropsychopharmacol; 1998 May; 8(2):127-9. PubMed ID: 9619691
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Correlation of haloperidol levels between saliva and plasma of acutely ill schizophrenic patients.
    Jain T; Bhandari A; Ram V; Sharma S; Parakh M; Parakh MC
    Clin Biochem; 2011 Jun; 44(8-9):675-80. PubMed ID: 21458435
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Quantitation of itopride in human serum by high-performance liquid chromatography with fluorescence detection and its application to a bioequivalence study.
    Singh SS; Jain M; Sharma K; Shah B; Vyas M; Thakkar P; Shah R; Singh S; Lohray B
    J Chromatogr B Analyt Technol Biomed Life Sci; 2005 Apr; 818(2):213-20. PubMed ID: 15734161
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Resolution of the interference from carbamazepine and diphenhydramine during reversed-phase liquid chromatographic determination of haloperidol and reduced haloperidol.
    Vatassery GT; Holden LA; Dysken MW
    J Anal Toxicol; 1993 Sep; 17(5):304-6. PubMed ID: 8107466
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Determination of bisphenol A in rat brain by microdialysis and column switching high-performance liquid chromatography with fluorescence detection.
    Sun Y; Nakashima MN; Takahashi M; Kuroda N; Nakashima K
    Biomed Chromatogr; 2002 Aug; 16(5):319-26. PubMed ID: 12210505
    [TBL] [Abstract][Full Text] [Related]  

  • 30. High performance liquid chromatographic determination of azithromycin in serum using fluorescence detection and its application in human pharmacokinetic studies.
    Bahrami G; Mirzaeei S; Kiani A
    J Chromatogr B Analyt Technol Biomed Life Sci; 2005 Jun; 820(2):277-81. PubMed ID: 15876560
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Quantitative determination of clozapine in serum by instrumental planar chromatography.
    Mennickent S; Sobarzo A; Vega M; Godoy CG; de Diego M
    J Sep Sci; 2007 Aug; 30(13):2167-72. PubMed ID: 17638358
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Sensitive determination of 1- and 2-naphthol in human plasma by HPLC-fluorescence detection with 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride as a labeling reagent.
    Ohyama K; Kishikawa N; Matayoshi K; Adutwum LA; Wada M; Nakashima K; Kuroda N
    J Sep Sci; 2009 Jul; 32(13):2218-22. PubMed ID: 19569101
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Haloperidol and reduced haloperidol serum levels: correlation with psychopathology in acute schizophrenia.
    Stevens A; Mahal A; Gaertner HJ
    Pharmacopsychiatry; 1992 Sep; 25(5):218-23. PubMed ID: 1409866
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Liquid chromatographic determination of reduced haloperidol and haloperidol concentrations in packed red blood cells from humans.
    Vatassery GT; Herzan LA; Dysken MW
    J Anal Toxicol; 1990; 14(1):25-8. PubMed ID: 2314059
    [TBL] [Abstract][Full Text] [Related]  

  • 35. 1,3,5,7-Tetramethyl-8-aminozide-difluoroboradiaza-s-indacene as a new fluorescent labeling reagent for the determination of aliphatic aldehydes in serum with high performance liquid chromatography.
    Xiong XJ; Wang H; Rao WB; Guo XF; Zhang HS
    J Chromatogr A; 2010 Jan; 1217(1):49-56. PubMed ID: 19942225
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Sensitive electrochemical high-performance liquid chromatography assay for the simultaneous determination of haloperidol and reduced haloperidol.
    Eddington ND; Young D
    J Pharm Sci; 1988 Jun; 77(6):541-3. PubMed ID: 3171937
    [TBL] [Abstract][Full Text] [Related]  

  • 37. High-performance liquid chromatographic method for the detection and quantitation of haloperidol and seven of its metabolites in microsomal preparations.
    Fang J; Gorrod JW
    J Chromatogr; 1993 May; 614(2):267-73. PubMed ID: 8314939
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Highly sensitive determination of nitric oxide in biologic samples by a near-infrared BODIPY-based fluorescent probe coupled with high-performance liquid chromatography.
    Zhang HX; Chen JB; Guo XF; Wang H; Zhang HS
    Talanta; 2013 Nov; 116():335-42. PubMed ID: 24148412
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Determination of losartan, telmisartan, and valsartan by direct injection of human urine into a column-switching liquid chromatographic system with fluorescence detection.
    del Rosario Brunetto M; Contreras Y; Clavijo S; Torres D; Delgado Y; Ovalles F; Ayala C; Gallignani M; Estela JM; Martin VC
    J Pharm Biomed Anal; 2009 Sep; 50(2):194-9. PubMed ID: 19446420
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Determination of NVP-BEZ235, a dual PI3K and mTOR inhibitor, in human and mouse plasma and in mouse tissue homogenates by reversed-phase high-performance liquid chromatography with fluorescence detection.
    Lin F; Chandrasekaran G; de Gooijer MC; Beijnen JH; van Tellingen O
    J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Jul; 901():9-17. PubMed ID: 22727754
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.