These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. A single-centre experience and follow-up of patients with endovascular coiling of large and giant intracranial aneurysms with parent artery preservation. Gao X; Liang G; Li Z; Wei X; Cao P J Clin Neurosci; 2012 Mar; 19(3):364-9. PubMed ID: 22277568 [TBL] [Abstract][Full Text] [Related]
5. Modified balloon assisted coil embolization for the treatment of intracranial and cervical arterial aneurysms using coaxial dual lumen balloon microcatheters: initial experience. Jagadeesan BD; Siddiq F; Grande AW; Tummala RP J Neurointerv Surg; 2014 Nov; 6(9):704-7. PubMed ID: 24153339 [TBL] [Abstract][Full Text] [Related]
7. Early postmarket results after treatment of intracranial aneurysms with the pipeline embolization device: a U.S. multicenter experience. Kan P; Siddiqui AH; Veznedaroglu E; Liebman KM; Binning MJ; Dumont TM; Ogilvy CS; Gaughen JR; Mocco J; Velat GJ; Ringer AJ; Welch BG; Horowitz MB; Snyder KV; Hopkins LN; Levy EI Neurosurgery; 2012 Dec; 71(6):1080-7; discussion 1087-8. PubMed ID: 22948199 [TBL] [Abstract][Full Text] [Related]
8. Comparison of techniques for stent assisted coil embolization of aneurysms. Spiotta AM; Wheeler AM; Smithason S; Hui F; Moskowitz S J Neurointerv Surg; 2012 Sep; 4(5):339-44. PubMed ID: 21990514 [TBL] [Abstract][Full Text] [Related]
9. Frequency and factors associated with unsuccessful lead (first) coil placement in patients undergoing coil embolization of intracranial aneurysms. Khatri R; Chaudhry SA; Rodriguez GJ; Suri MF; Cordina SM; Qureshi AI Neurosurgery; 2013 Mar; 72(3):452-8; discussion 458. PubMed ID: 23208061 [TBL] [Abstract][Full Text] [Related]
10. Balloon-assisted coil embolization. "Surgical clip application should be considered as a first treatment option in large and wide-necked aneurysms". Bendszus M; Chapot R J Neurosurg; 2007 Apr; 106(4):734-5; author reply 735. PubMed ID: 17432735 [No Abstract] [Full Text] [Related]
11. Thromboembolic events associated with balloon-assisted coil embolization: evaluation with diffusion-weighted MR imaging. Albayram S; Selcuk H; Kara B; Bozdag E; Uzma O; Kocer N; Islak C AJNR Am J Neuroradiol; 2004; 25(10):1768-77. PubMed ID: 15569744 [TBL] [Abstract][Full Text] [Related]
12. Volume versus standard coils in the treatment of intracranial aneurysms. Kaesmacher J; Müller-Leisse C; Huber T; Boeckh-Behrens T; Haller B; Shiban E; Friedrich B; Zimmer C; Dorn F; Prothmann S J Neurointerv Surg; 2016 Oct; 8(10):1034-40. PubMed ID: 26491040 [TBL] [Abstract][Full Text] [Related]
13. Stent salvage using the Enterprise stent for procedure-related complication during coil embolization of ruptured intracranial aneurysms. Chung J; Kim YB; Hong CK; Joo JY; Shin YS; Lim YC Acta Neurochir (Wien); 2013 Feb; 155(2):223-9. PubMed ID: 23149588 [TBL] [Abstract][Full Text] [Related]