These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

169 related articles for article (PubMed ID: 16967067)

  • 1. [False measurement of glucose during dialysis with icodextrin].
    Husøy AM; Knudsen GR; Thierley M; Svarstad E
    Tidsskr Nor Laegeforen; 2006 Sep; 126(17):2268-70. PubMed ID: 16967067
    [TBL] [Abstract][Full Text] [Related]  

  • 2. False elevation of blood glucose levels measured by GDH-PQQ-based glucometers occurs during all daily dwells in peritoneal dialysis patients using icodextrin.
    Tsai CY; Lee SC; Hung CC; Lee JJ; Kuo MC; Hwang SJ; Chen HC
    Perit Dial Int; 2010; 30(3):329-35. PubMed ID: 20190030
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Analytical interferences in point-of-care testing glucometers by icodextrin and its metabolites: an overview.
    Floré KM; Delanghe JR
    Perit Dial Int; 2009; 29(4):377-83. PubMed ID: 19602602
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A previously undescribed side effect of icodextrin: overestimation of glycemia by glucose analyzer.
    Wens R; Taminne M; Devriendt J; Collart F; Broeders N; Mestrez F; Germanos H; Dratwa M
    Perit Dial Int; 1998; 18(6):603-9. PubMed ID: 9932659
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The danger of using inappropriate point-of-care glucose meters in patients on icodextrin dialysis.
    Perera NJ; Stewart PM; Williams PF; Chua EL; Yue DK; Twigg SM
    Diabet Med; 2011 Oct; 28(10):1272-6. PubMed ID: 21679233
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Falsely Elevated Glucose Concentrations in Peritoneal Dialysis Patients Using Icodextrin.
    Dogan K; Kayalp D; Ceylan G; Azak A; Senes M; Duranay M; Yucel D
    J Clin Lab Anal; 2016 Sep; 30(5):506-9. PubMed ID: 26511081
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Inaccurate self-monitoring of blood glucose readings in patients on chronic ambulatory peritoneal dialysis with icodextrin.
    Pavlicek V; Garzoni D; Urech P; Brändle M
    Exp Clin Endocrinol Diabetes; 2006 Mar; 114(3):124-6. PubMed ID: 16636978
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of several point-of-care testing (POCT) glucometers with an established laboratory procedure for the diagnosis of type 2 diabetes using the discordance rate. A new statistical approach.
    Püntmann I; Wosniok W; Haeckel R
    Clin Chem Lab Med; 2003 Jun; 41(6):809-20. PubMed ID: 12880146
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Icodextrine and insulin resistance in continuous ambulatory peritoneal dialysis patients.
    Canbakan M; Sahin GM
    Ren Fail; 2007; 29(3):289-93. PubMed ID: 17497442
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Severe cutaneous hypersensitivity to icodextrin in a continuous ambulatory peritoneal dialysis patient.
    Lee SH; Park HC; Sim SR; Chung SJ; Kim KJ; Park WI; Hong SW; Ha SK
    J Nephrol; 2006; 19(5):673-6. PubMed ID: 17136700
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Clinical experience with icodextrin. Multicenter study].
    Guerrero A; Montes R; Martín-Herrera C; Ruiz A; Remón C; Fernández-Ruiz EJ; Pérez-Bañasco V; Benítez M; Martínez-Benavides E; Martínez-González JM; Torán D; Tejuca F; Páez C; del Pino MD
    Nefrologia; 2001; 21(6):574-80. PubMed ID: 11881427
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Allergic reactions to the polymeric glucose-based peritoneal dialysis fluid icodextrin in patients with renal failure.
    Goldsmith D; Jayawardene S; Sabharwal N; Cooney K
    Lancet; 2000 Mar; 355(9207):897. PubMed ID: 10752708
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Masked hypoglycemia in the presence of icodextrin for peritoneal dialysis.
    Khouli MM
    J Emerg Med; 2013 Feb; 44(2):e191-3. PubMed ID: 22579020
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Icodextrin - still a cause for concern with blood glucose monitoring in continuous ambulatory peritoneal dialysis patients with diabetes.
    Slim S; Griffiths MJ; Gama R
    Ann Clin Biochem; 2007 Mar; 44(Pt 2):196-7. PubMed ID: 17362588
    [No Abstract]   [Full Text] [Related]  

  • 15. Avoidable iatrogenic hypoglycemia in patients on peritoneal dialysis: the risks of nonspecific glucose monitoring devices and drug-device interaction.
    Firanek CA; Jacob DT; Sloand JA
    J Patient Saf; 2014 Dec; 10(4):218-21. PubMed ID: 23860196
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Hypoglycaemic coma due to falsely elevated glucose values in a patient with diabetes mellitus and peritoneal dialysis].
    Nienhuis WA; Bruijns RH; Vastenburg G; Wouters RS
    Ned Tijdschr Geneeskd; 2006 Jul; 150(28):1574-6. PubMed ID: 16886696
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Unexplained hypotension and exertional dyspnea in a night-cycled peritoneal dialysis patient--a rare form of icodextrin hypersensitivity.
    Onuigbo MA
    Adv Perit Dial; 2014; 30():87-9. PubMed ID: 25338427
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hypoglycemic coma in a diabetic patient on peritoneal dialysis due to interference of icodextrin metabolites with capillary blood glucose measurements.
    Disse E; Thivolet C
    Diabetes Care; 2004 Sep; 27(9):2279. PubMed ID: 15333503
    [No Abstract]   [Full Text] [Related]  

  • 19. Icodextrin-induced acute pancreatitis in a peritoneal dialysis patient: a case report and literature review
.
    Rubinstein S; Franjul R; Surana S; Fogel J
    Clin Nephrol; 2016 Nov; 86 (2016)(11):283-286. PubMed ID: 27616762
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Severe peritoneal mononucleosis associated with icodextrin use in continuous ambulatory peritoneal dialysis.
    Martín J; Sansone G; Cirugeda A; Sánchez-Tomero JA; Muñoz C; Selgas R
    Adv Perit Dial; 2003; 19():191-4. PubMed ID: 14763060
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.