These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

180 related articles for article (PubMed ID: 16972009)

  • 1. Creating an IHE ATNA-based audit repository.
    Gregg B; D'Agostino H; Toledo EG
    J Digit Imaging; 2006 Dec; 19(4):307-15. PubMed ID: 16972009
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Multidimensional analysis: a management tool for monitoring HIPAA compliance and departmental performance.
    Coleman RM; Ralston MD; Szafran A; Beaulieu DM
    J Digit Imaging; 2004 Sep; 17(3):196-204. PubMed ID: 15534752
    [TBL] [Abstract][Full Text] [Related]  

  • 3. HIS/RIS/PACS integration: getting to the gold standard.
    Boochever SS
    Radiol Manage; 2004; 26(3):16-24; quiz 25-7. PubMed ID: 15259683
    [TBL] [Abstract][Full Text] [Related]  

  • 4. HIPAA compliant auditing system for medical images.
    Zhou Z; Liu BJ
    Comput Med Imaging Graph; 2005; 29(2-3):235-41. PubMed ID: 15755540
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A HIPAA-compliant architecture for securing clinical images.
    Liu BJ; Zhou Z; Huang HK
    J Digit Imaging; 2006 Jun; 19(2):172-80. PubMed ID: 16341963
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The development of an application for data privacy by applying an audit repository based on IHE ATNA.
    Bresser L; Köhler S; Schwaab C
    Stud Health Technol Inform; 2014; 198():219-25. PubMed ID: 24825706
    [TBL] [Abstract][Full Text] [Related]  

  • 7. From IHE Audit Trails to XES Event Logs Facilitating Process Mining.
    Paster F; Helm E
    Stud Health Technol Inform; 2015; 210():40-4. PubMed ID: 25991098
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Implementing a full-feature PACS solution in accordance with the IHE technical framework: the CHILI approach.
    Hussein R; Engelmann U; Schroeter A; Meinzer HP
    Acad Radiol; 2004 Apr; 11(4):439-47. PubMed ID: 15109016
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A IHE-Like Approach Method for Quantitative Analysis of PACS Usage.
    Calabrese R; Beltrame M; Accardo A
    J Digit Imaging; 2016 Dec; 29(6):658-664. PubMed ID: 26969600
    [TBL] [Abstract][Full Text] [Related]  

  • 10. HIPPA's compliant Auditing System for Medical Imaging System.
    Chen X; Zhang J; Wu D; Han R
    Conf Proc IEEE Eng Med Biol Soc; 2005; 2006():562-3. PubMed ID: 17282242
    [TBL] [Abstract][Full Text] [Related]  

  • 11. IHE profiles applied to regional PACS.
    Fernandez-Bayó J
    Eur J Radiol; 2011 May; 78(2):250-2. PubMed ID: 20580180
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Integration of computer-aided diagnosis/detection (CAD) results in a PACS environment using CAD-PACS toolkit and DICOM SR.
    Le AH; Liu B; Huang HK
    Int J Comput Assist Radiol Surg; 2009 Jun; 4(4):317-29. PubMed ID: 20033579
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [IHE ITI-ATNA profile-based solution for the security of regional healthcare information sharing].
    Yao YH; Zhang JG
    Zhongguo Yi Liao Qi Xie Za Zhi; 2008 Sep; 32(5):332-6. PubMed ID: 19119651
    [TBL] [Abstract][Full Text] [Related]  

  • 14. CAD-PACS integration tool kit based on DICOM secondary capture, structured report and IHE workflow profiles.
    Zhou Z; Liu BJ; Le AH
    Comput Med Imaging Graph; 2007; 31(4-5):346-52. PubMed ID: 17386997
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Using IHE and HL7 conformance to specify consistent PACS interoperability for a large multi-center enterprise.
    Henderson ML; Dayhoff RE; Titton CP; Casertano A
    J Healthc Inf Manag; 2006; 20(3):47-53. PubMed ID: 16903661
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Medical image security in a HIPAA mandated PACS environment.
    Cao F; Huang HK; Zhou XQ
    Comput Med Imaging Graph; 2003; 27(2-3):185-96. PubMed ID: 12620309
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Integrating and Adopting AI in the Radiology Workflow: A Primer for Standards and Integrating the Healthcare Enterprise (IHE) Profiles.
    Tejani AS; Cook TS; Hussain M; Sippel Schmidt T; O'Donnell KP
    Radiology; 2024 Jun; 311(3):e232653. PubMed ID: 38888474
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cybersecurity Challenges for PACS and Medical Imaging.
    Eichelberg M; Kleber K; Kämmerer M
    Acad Radiol; 2020 Aug; 27(8):1126-1139. PubMed ID: 32418786
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Business Model for the Security of a Large-Scale PACS, Compliance with ISO/27002:2013 Standard.
    Gutiérrez-Martínez J; Núñez-Gaona MA; Aguirre-Meneses H
    J Digit Imaging; 2015 Aug; 28(4):481-91. PubMed ID: 25634674
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Security model for picture archiving and communication systems.
    Harding DB; Gac RJ; Reynolds CT; Romlein J; Chacko AK
    J Digit Imaging; 2000 May; 13(2 Suppl 1):202-3. PubMed ID: 10847401
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.