These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
149 related articles for article (PubMed ID: 16973780)
1. An investigation of operator exposure in interventional radiology. Schueler BA; Vrieze TJ; Bjarnason H; Stanson AW Radiographics; 2006; 26(5):1533-41; discussion 1541. PubMed ID: 16973780 [TBL] [Abstract][Full Text] [Related]
2. Reduction of operator radiation dose by an extended lower body shield. Gonzales JP; Moran C; Silberzweig JE J Vasc Interv Radiol; 2014 Mar; 25(3):462-8, 468.e1. PubMed ID: 24332242 [TBL] [Abstract][Full Text] [Related]
3. Fluoroscopically guided percutaneous vertebroplasty: assessment of radiation doses and implementation of procedural routines to reduce operator exposure. von Wrangel A; Cederblad A; Rodriguez-Catarino M Acta Radiol; 2009 Jun; 50(5):490-6. PubMed ID: 19363715 [TBL] [Abstract][Full Text] [Related]
4. Occupational radiation doses to operators performing cardiac catheterization procedures. Kim KP; Miller DL; Balter S; Kleinerman RA; Linet MS; Kwon D; Simon SL Health Phys; 2008 Mar; 94(3):211-27. PubMed ID: 18301095 [TBL] [Abstract][Full Text] [Related]
5. Step back from the patient: reduction of radiation dose to the operator by the systematic use of an automatic power injector for contrast media in an interventional angiography suite. Larsen AS; Osterås BH Acta Radiol; 2012 Apr; 53(3):330-4. PubMed ID: 22334873 [TBL] [Abstract][Full Text] [Related]
6. Impact of the incorrect use of lead drapes on staff and patient doses in interventional radiology. Lima TVM; Del Castillo TR; Heinrich M; Zihlmann S; Benitez RL; Roos JE J Radiol Prot; 2022 Feb; 42(2):. PubMed ID: 35072655 [TBL] [Abstract][Full Text] [Related]
7. Identification of less-irradiating tube angulations in invasive cardiology. Kuon E; Dahm JB; Empen K; Robinson DM; Reuter G; Wucherer M J Am Coll Cardiol; 2004 Oct; 44(7):1420-8. PubMed ID: 15464322 [TBL] [Abstract][Full Text] [Related]
14. Is lead shielding of patients necessary during fluoroscopic procedures? A study based on kyphoplasty. Smith JR; Marsh RM; Silosky MS Skeletal Radiol; 2018 Jan; 47(1):37-43. PubMed ID: 28821928 [TBL] [Abstract][Full Text] [Related]
15. Evaluation of the dose to the patient and medical staff in interventional cardiology employing computational models. Ferrari P; Venturi G; Gualdrini G; Rossi PL; Mariselli M; Zannoli R Radiat Prot Dosimetry; 2010 Sep; 141(1):82-5. PubMed ID: 20457663 [TBL] [Abstract][Full Text] [Related]