BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

412 related articles for article (PubMed ID: 16977292)

  • 1. The use of a water seal to manage air leaks after a pulmonary lobectomy: a retrospective study.
    Okamoto J; Okamoto T; Fukuyama Y; Ushijima C; Yamaguchi M; Ichinose Y
    Ann Thorac Cardiovasc Surg; 2006 Aug; 12(4):242-4. PubMed ID: 16977292
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A prospective randomized controlled trial of suction versus non-suction to the under-water seal drains following lung resection.
    Alphonso N; Tan C; Utley M; Cameron R; Dussek J; Lang-Lazdunski L; Treasure T
    Eur J Cardiothorac Surg; 2005 Mar; 27(3):391-4. PubMed ID: 15740944
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of water seal and suction after pulmonary lobectomy: a prospective, randomized trial.
    Brunelli A; Monteverde M; Borri A; Salati M; Marasco RD; Al Refai M; Fianchini A
    Ann Thorac Surg; 2004 Jun; 77(6):1932-7; discussion 1937. PubMed ID: 15172239
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Initial chest tube management after pulmonary resection.
    Antanavicius G; Lamb J; Papasavas P; Caushaj P
    Am Surg; 2005 May; 71(5):416-9. PubMed ID: 15986973
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Alternate suction reduces prolonged air leak after pulmonary lobectomy: a randomized comparison versus water seal.
    Brunelli A; Sabbatini A; Xiume' F; Refai MA; Salati M; Marasco R
    Ann Thorac Surg; 2005 Sep; 80(3):1052-5. PubMed ID: 16122484
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A proposal for management after lung resection, using a flexible silastic drain.
    Kamiyoshihara M; Nagashima T; Ibe T
    Asian Cardiovasc Thorac Ann; 2010 Oct; 18(5):435-42. PubMed ID: 20947597
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Chest tube management following pulmonary lobectomy: change of protocol results in fewer air leaks.
    Bertholet JW; Joosten JJ; Keemers-Gels ME; van den Wildenberg FJ; Barendregt WB
    Interact Cardiovasc Thorac Surg; 2011 Jan; 12(1):28-31. PubMed ID: 20926462
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Regulated tailored suction vs regulated seal: a prospective randomized trial on air leak duration.
    Brunelli A; Salati M; Pompili C; Refai M; Sabbatini A
    Eur J Cardiothorac Surg; 2013 May; 43(5):899-904. PubMed ID: 23024236
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Avoiding chest tube placement after video-assisted thoracoscopic wedge resection of the lung.
    Watanabe A; Watanabe T; Ohsawa H; Mawatari T; Ichimiya Y; Takahashi N; Sato H; Abe T
    Eur J Cardiothorac Surg; 2004 May; 25(5):872-6. PubMed ID: 15082297
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Morbidity in video-assisted thoracoscopic lobectomy for clinical stage I non-small cell lung cancer: is VATS lobectomy really safe?
    Kawachi R; Tsukada H; Nakazato Y; Takei H; Koshi-ishi Y; Goya T
    Thorac Cardiovasc Surg; 2009 Apr; 57(3):156-9. PubMed ID: 19330753
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Preliminary report of a prospective, randomized trial of underwater seal for spontaneous and iatrogenic pneumothorax.
    Reed MF; Lyons JM; Luchette FA; Neu JA; Howington JA
    J Am Coll Surg; 2007 Jan; 204(1):84-90. PubMed ID: 17189116
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Prospective randomized trial compares suction versus water seal for air leaks.
    Cerfolio RJ; Bass C; Katholi CR
    Ann Thorac Surg; 2001 May; 71(5):1613-7. PubMed ID: 11383809
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Randomized study of algorithms for discontinuing tube thoracostomy drainage.
    Davis JW; Mackersie RC; Hoyt DB; Garcia J
    J Am Coll Surg; 1994 Nov; 179(5):553-7. PubMed ID: 7952457
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Postoperative chest tube management: measuring air leak using an electronic device decreases variability in the clinical practice.
    Varela G; Jiménez MF; Novoa NM; Aranda JL
    Eur J Cardiothorac Surg; 2009 Jan; 35(1):28-31. PubMed ID: 18848460
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Efficiency of fleece-bound sealing (TachoSil) of air leaks in lung surgery: a prospective randomised trial.
    Anegg U; Lindenmann J; Matzi V; Smolle J; Maier A; Smolle-Jüttner F
    Eur J Cardiothorac Surg; 2007 Feb; 31(2):198-202. PubMed ID: 17187983
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Autologous fibrin sealant reduces the incidence of prolonged air leak and duration of chest tube drainage after lung volume reduction surgery: a prospective randomized blinded study.
    Moser C; Opitz I; Zhai W; Rousson V; Russi EW; Weder W; Lardinois D
    J Thorac Cardiovasc Surg; 2008 Oct; 136(4):843-9. PubMed ID: 18954621
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Video-assisted thoracic surgery for primary spontaneous pneumothorax in children: is there an optimal technique?
    Bialas RC; Weiner TM; Phillips JD
    J Pediatr Surg; 2008 Dec; 43(12):2151-5. PubMed ID: 19040924
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Intrapleural instillation of autologous blood in the treatment of prolonged air leak after lobectomy: a prospective randomized controlled trial.
    Shackcloth MJ; Poullis M; Jackson M; Soorae A; Page RD
    Ann Thorac Surg; 2006 Sep; 82(3):1052-6. PubMed ID: 16928534
    [TBL] [Abstract][Full Text] [Related]  

  • 19. AIRFIX: the first digital postoperative chest tube airflowmetry--a novel method to quantify air leakage after lung resection.
    Anegg U; Lindenmann J; Matzi V; Mujkic D; Maier A; Fritz L; Smolle-Jüttner FM
    Eur J Cardiothorac Surg; 2006 Jun; 29(6):867-72. PubMed ID: 16675248
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The management of chest tubes in patients with a pneumothorax and an air leak after pulmonary resection.
    Cerfolio RJ; Bryant AS; Singh S; Bass CS; Bartolucci AA
    Chest; 2005 Aug; 128(2):816-20. PubMed ID: 16100173
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 21.