BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

533 related articles for article (PubMed ID: 16980318)

  • 1. Comparison of the effects of exposure to light in Harshaw LiF:Mg,Ti and LiF:Mg,Cu,P.
    Baker ST; Gilvin PJ
    Radiat Prot Dosimetry; 2007; 125(1-4):258-60. PubMed ID: 16980318
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of time effects, decision limit and residual signal in Harshaw LiF:Mg,Ti and LiF:Mg,Cu,P.
    Gilvin PJ
    Radiat Prot Dosimetry; 2007; 125(1-4):233-6. PubMed ID: 17293354
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dosimetric properties of new cards with high-sensitivity MCP-N (LiF:Mg,Cu,P) detectors for Harshaw automatic reader.
    Budzanowski M; Bilski P; Olko P; Ryba E; Perle S; Majewski M
    Radiat Prot Dosimetry; 2007; 125(1-4):251-3. PubMed ID: 17020912
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A comparative study on the susceptibility of LiF:Mg,Ti (TLD-100) and LiF:Mg,Cu,P (TLD-100H) to spurious signals in thermoluminescence dosimetry.
    Al-Haj A; Lagarde C; Mahyoub F
    Radiat Prot Dosimetry; 2007; 125(1-4):399-402. PubMed ID: 17223633
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Further studies in the reduction of residual in Harshaw TLD-100H (LiF:Mg,Cu,P).
    Ramlo M; Moscovitch M; Rotunda JE
    Radiat Prot Dosimetry; 2007; 125(1-4):217-9. PubMed ID: 17416592
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Energy response of LiF and Mg2SiO4 TLDs to 10-150 keV monoenergetic photons.
    Konnai A; Nariyama N; Ohnishi S; Odano N
    Radiat Prot Dosimetry; 2005; 115(1-4):334-6. PubMed ID: 16381741
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The application of LiF:Mg,Cu,P to large scale personnel dosimetry: current status and future directions.
    Moscovitch M; St John TJ; Cassata JR; Blake PK; Rotunda JE; Ramlo M; Velbeck KJ; Luo LZ
    Radiat Prot Dosimetry; 2006; 119(1-4):248-54. PubMed ID: 16835277
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dosimetry of densely ionising radiation with three LiF phosphors for space applications.
    Bilski P
    Radiat Prot Dosimetry; 2006; 120(1-4):397-400. PubMed ID: 16731689
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Performance of Harshaw TLD-100H two-element Dosemeter.
    Luo LZ; Rotunda JE
    Radiat Prot Dosimetry; 2006; 120(1-4):324-30. PubMed ID: 16644944
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development of LiF:Mg,Cu,Si TL material (new KLT-300) with a low-residual signal and high-thermal stability.
    Lee JI; Kim JL; Rahman MS; Chang SY; Chung KS; Choe HS
    Radiat Prot Dosimetry; 2007; 125(1-4):229-32. PubMed ID: 16968712
    [TBL] [Abstract][Full Text] [Related]  

  • 11. LiF:Mg,Cu,P glow curve shape dependence on heating rate.
    Luo LZ; Velbeck KJ; Moscovitch M; Rotunda JE
    Radiat Prot Dosimetry; 2006; 119(1-4):184-90. PubMed ID: 16581930
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pre- and post-irradiation fading of 6LiF:Mg,Ti (TLD-600) exposed to thermal neutrons.
    Vainblat N; German U; Weinstein M; Alfassi ZB
    Radiat Prot Dosimetry; 2007; 126(1-4):318-21. PubMed ID: 17496295
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Batch homogeneity of LiF(Mg,Cu,P)-GR200 and LiF(Mg,Cu,P)-MCP-NS TL detectors for use as extremity dosemeters at ENEA personal dosimetry service.
    Mariotti F; Uleri G; Fantuzzi E
    Radiat Prot Dosimetry; 2006; 120(1-4):283-8. PubMed ID: 16702241
    [TBL] [Abstract][Full Text] [Related]  

  • 14. On neutron-gamma mixed field dosimetry with LiF:Mg,Ti at radiation protection dose levels.
    Weinstein M; German U; Alfassi ZB
    Radiat Prot Dosimetry; 2006; 119(1-4):314-8. PubMed ID: 16735561
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Advanced multistage deconvolution applied to composite glow peak 5 in LiF:Mg,Ti (TLD-100).
    Horowitz YS; Fuks E; Oster L; Podpalov L; Belaish Y; Shachar BB
    Radiat Prot Dosimetry; 2007; 126(1-4):322-5. PubMed ID: 17517677
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparative study of LiF:Mg,Cu,Na,Si and Li2B4O7:Cu,Ag,P TL detectors.
    Miljanić S; Ranogajec-Komor M; Knezević Z; Stuhec M; Prokić M
    Radiat Prot Dosimetry; 2006; 119(1-4):191-6. PubMed ID: 16709712
    [TBL] [Abstract][Full Text] [Related]  

  • 17. On the roles of the dopants in LiF: Mg,Cu,Na,Si thermoluminescent material.
    Lee JI; Kim JL; Chang SY; Chung KS; Choe HS
    Radiat Prot Dosimetry; 2005; 115(1-4):340-4. PubMed ID: 16381743
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comments on 'The thermoluminescence dose-response and other characteristics of the high-temperature TL in LiF: Mg.Ti (TLD-100)' by Y.S. Horowitz, L. Oster and H. Datz.
    German U; Weinstein M; Abraham A; Alfassi ZB
    Radiat Prot Dosimetry; 2008; 128(4):509-10; author reply 510-5. PubMed ID: 18420571
    [No Abstract]   [Full Text] [Related]  

  • 19. Pre-irradiation and post-irradiation fading of the Harshaw 8841 TLD in different environmental conditions.
    Jones LA; Stokes RP
    Radiat Prot Dosimetry; 2007; 125(1-4):241-6. PubMed ID: 17008363
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of two extremity dosemeters based on LiF:Mg,Cu,P thin detectors for mixed beta-gamma fields.
    Ginjaume M; Pérez S; Ortega X; Duch MA
    Radiat Prot Dosimetry; 2006; 120(1-4):316-20. PubMed ID: 16644980
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 27.