BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

768 related articles for article (PubMed ID: 16982558)

  • 1. Respiration correlated cone-beam computed tomography and 4DCT for evaluating target motion in Stereotactic Lung Radiation Therapy.
    Purdie TG; Moseley DJ; Bissonnette JP; Sharpe MB; Franks K; Bezjak A; Jaffray DA
    Acta Oncol; 2006; 45(7):915-22. PubMed ID: 16982558
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantifying interfraction and intrafraction tumor motion in lung stereotactic body radiotherapy using respiration-correlated cone beam computed tomography.
    Bissonnette JP; Franks KN; Purdie TG; Moseley DJ; Sonke JJ; Jaffray DA; Dawson LA; Bezjak A
    Int J Radiat Oncol Biol Phys; 2009 Nov; 75(3):688-95. PubMed ID: 19395200
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Verification of planning target volume settings in volumetric modulated arc therapy for stereotactic body radiation therapy by using in-treatment 4-dimensional cone beam computed tomography.
    Takahashi W; Yamashita H; Kida S; Masutani Y; Sakumi A; Ohtomo K; Nakagawa K; Haga A
    Int J Radiat Oncol Biol Phys; 2013 Jul; 86(3):426-31. PubMed ID: 23562767
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of interfractional variation of the centroid position and volume of internal target volume during stereotactic body radiotherapy of lung cancer using cone-beam computed tomography.
    Sun Y; Ge H; Cheng S; Yang C; Zhu Q; Li D; Tian Y
    J Appl Clin Med Phys; 2016 Mar; 17(2):461-472. PubMed ID: 27074466
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of immobilization and performance status on intrafraction motion for stereotactic lung radiotherapy: analysis of 133 patients.
    Li W; Purdie TG; Taremi M; Fung S; Brade A; Cho BC; Hope A; Sun A; Jaffray DA; Bezjak A; Bissonnette JP
    Int J Radiat Oncol Biol Phys; 2011 Dec; 81(5):1568-75. PubMed ID: 21075559
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Frameless stereotactic body radiotherapy for lung cancer using four-dimensional cone beam CT guidance.
    Sonke JJ; Rossi M; Wolthaus J; van Herk M; Damen E; Belderbos J
    Int J Radiat Oncol Biol Phys; 2009 Jun; 74(2):567-74. PubMed ID: 19046825
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Craniocaudal safety margin calculation based on interfractional changes in tumor motion in lung SBRT assessed with an EPID in cine mode.
    Ueda Y; Miyazaki M; Nishiyama K; Suzuki O; Tsujii K; Miyagi K
    Int J Radiat Oncol Biol Phys; 2012 Jul; 83(3):1064-9. PubMed ID: 22245190
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Variations of target volume definition and daily target volume localization in stereotactic body radiotherapy for early-stage non-small cell lung cancer patients under abdominal compression.
    Han C; Sampath S; Schultheisss TE; Wong JYC
    Med Dosim; 2017 Summer; 42(2):116-121. PubMed ID: 28433482
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Tumor motion changes in stereotactic body radiotherapy for liver tumors: an evaluation based on four-dimensional cone-beam computed tomography and fiducial markers.
    Shimohigashi Y; Toya R; Saito T; Ikeda O; Maruyama M; Yonemura K; Nakaguchi Y; Kai Y; Yamashita Y; Oya N; Araki F
    Radiat Oncol; 2017 Mar; 12(1):61. PubMed ID: 28335794
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Markerless tracking of small lung tumors for stereotactic radiotherapy.
    van Sörnsen de Koste JR; Dahele M; Mostafavi H; Sloutsky A; Senan S; Slotman BJ; Verbakel WF
    Med Phys; 2015 Apr; 42(4):1640-52. PubMed ID: 25832054
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dosimetric impact of breathing motion in lung stereotactic body radiotherapy treatment using intensity modulated radiotherapy and volumetric modulated arc therapy [corrected].
    Rao M; Wu J; Cao D; Wong T; Mehta V; Shepard D; Ye J
    Int J Radiat Oncol Biol Phys; 2012 Jun; 83(2):e251-6. PubMed ID: 22365622
    [TBL] [Abstract][Full Text] [Related]  

  • 12. 4D imaging for target definition in stereotactic radiotherapy for lung cancer.
    Slotman BJ; Lagerwaard FJ; Senan S
    Acta Oncol; 2006; 45(7):966-72. PubMed ID: 16982565
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effect of irregular breathing patterns on internal target volumes in four-dimensional CT and cone-beam CT images in the context of stereotactic lung radiotherapy.
    Clements N; Kron T; Franich R; Dunn L; Roxby P; Aarons Y; Chesson B; Siva S; Duplan D; Ball D
    Med Phys; 2013 Feb; 40(2):021904. PubMed ID: 23387752
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Intrafraction 4D-cone beam CT acquired during volumetric arc radiotherapy delivery: kV parameter optimization and 4D motion accuracy for lung stereotactic body radiotherapy (SBRT) patients.
    Liang J; Lack D; Zhou J; Liu Q; Grills I; Yan D
    J Appl Clin Med Phys; 2019 Dec; 20(12):10-24. PubMed ID: 31675150
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Investigation of respiration induced intra- and inter-fractional tumour motion using a standard Cone Beam CT.
    Gottlieb KL; Hansen CR; Hansen O; Westberg J; Brink C
    Acta Oncol; 2010 Oct; 49(7):1192-8. PubMed ID: 20831512
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of the cone beam CT for internal target volume localization in lung stereotactic radiotherapy in comparison with 4D MIP images.
    Wang L; Chen X; Lin MH; Xue J; Lin T; Fan J; Jin L; Ma CM
    Med Phys; 2013 Nov; 40(11):111709. PubMed ID: 24320417
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accuracy and inter-observer variability of 3D versus 4D cone-beam CT based image-guidance in SBRT for lung tumors.
    Sweeney RA; Seubert B; Stark S; Homann V; Müller G; Flentje M; Guckenberger M
    Radiat Oncol; 2012 Jun; 7():81. PubMed ID: 22682767
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dosimetric impact of online correction via cone-beam CT-based image guidance for stereotactic lung radiotherapy.
    Galerani AP; Grills I; Hugo G; Kestin L; Mohammed N; Chao KK; Suen A; Martinez A; Yan D
    Int J Radiat Oncol Biol Phys; 2010 Dec; 78(5):1571-8. PubMed ID: 20646857
    [TBL] [Abstract][Full Text] [Related]  

  • 19. 4DCT and CBCT based PTV margin in Stereotactic Body Radiotherapy(SBRT) of non-small cell lung tumor adhered to chest wall or diaphragm.
    Li Y; Ma JL; Chen X; Tang FW; Zhang XZ
    Radiat Oncol; 2016 Nov; 11(1):152. PubMed ID: 27846900
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dynamic volume vs respiratory correlated 4DCT for motion assessment in radiation therapy simulation.
    Coolens C; Bracken J; Driscoll B; Hope A; Jaffray D
    Med Phys; 2012 May; 39(5):2669-81. PubMed ID: 22559637
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 39.