These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
105 related articles for article (PubMed ID: 16986461)
21. Spectral distribution of particle fluence in small field detectors and its implication on small field dosimetry. Benmakhlouf H; Andreo P Med Phys; 2017 Feb; 44(2):713-724. PubMed ID: 28032369 [TBL] [Abstract][Full Text] [Related]
22. A procedure for calculation of monitor units for passively scattered proton radiotherapy beams. Sahoo N; Zhu XR; Arjomandy B; Ciangaru G; Lii M; Amos R; Wu R; Gillin MT Med Phys; 2008 Nov; 35(11):5088-97. PubMed ID: 19070243 [TBL] [Abstract][Full Text] [Related]
23. Dosimetry of therapeutic photon beams using an extended dose range film. Esthappan J; Mutic S; Harms WB; Dempsey JF; Low DA Med Phys; 2002 Oct; 29(10):2438-45. PubMed ID: 12408321 [TBL] [Abstract][Full Text] [Related]
24. Magnetic field influences on the lateral dose response functions of photon-beam detectors: MC study of wall-less water-filled detectors with various densities. Looe HK; Delfs B; Poppinga D; Harder D; Poppe B Phys Med Biol; 2017 Jun; 62(12):5131-5148. PubMed ID: 28398218 [TBL] [Abstract][Full Text] [Related]
25. [Dosimetry of small-size photon beams]. Manens JP; Buchheit I; Beauvais H; Gaboriaud G; Mazal A; Piret P Cancer Radiother; 1998; 2(2):105-14. PubMed ID: 9749105 [TBL] [Abstract][Full Text] [Related]
26. Experimental investigation of the response of an amorphous silicon EPID to intensity modulated radiotherapy beams. Greer PB; Vial P; Oliver L; Baldock C Med Phys; 2007 Nov; 34(11):4389-98. PubMed ID: 18072504 [TBL] [Abstract][Full Text] [Related]
27. Response to high-energy photons of PTW31014 PinPoint ion chamber with a central aluminum electrode. Agostinelli S; Garelli S; Piergentili M; Foppiano F Med Phys; 2008 Jul; 35(7):3293-301. PubMed ID: 18697554 [TBL] [Abstract][Full Text] [Related]
28. Relative dosimetry with an MR-linac: Response of ion chambers, diamond, and diode detectors for off-axis, depth dose, and output factor measurements. O'Brien DJ; Dolan J; Pencea S; Schupp N; Sawakuchi GO Med Phys; 2018 Feb; 45(2):884-897. PubMed ID: 29178457 [TBL] [Abstract][Full Text] [Related]
29. Electron contamination in 8 and 18 MV photon beams. Zhu TC; Palta JR Med Phys; 1998 Jan; 25(1):12-9. PubMed ID: 9472821 [TBL] [Abstract][Full Text] [Related]
30. [Radiophysical characteristics of different detectors for use in dosimetry]. Schwedas M; Scheithauer M; Wiezorek T; Wendt TG Z Med Phys; 2007; 17(3):172-9. PubMed ID: 17879814 [TBL] [Abstract][Full Text] [Related]
31. Feasibility of using a dose-area product ratio as beam quality specifier for photon beams with small field sizes. Pimpinella M; Caporali C; Guerra AS; Silvi L; De Coste V; Petrucci A; Delaunay F; Dufreneix S; Gouriou J; Ostrowsky A; Rapp B; Bordy JM; Daures J; Le Roy M; Sommier L; Vermesse D Phys Med; 2018 Jan; 45():106-116. PubMed ID: 29472074 [TBL] [Abstract][Full Text] [Related]
32. Dosimetric characteristics of the novel 2D ionization chamber array OCTAVIUS Detector 1500. Stelljes TS; Harmeyer A; Reuter J; Looe HK; Chofor N; Harder D; Poppe B Med Phys; 2015 Apr; 42(4):1528-37. PubMed ID: 25832043 [TBL] [Abstract][Full Text] [Related]
33. The output factor correction as function of the photon beam field size - direct measurement and calculation from the lateral dose response functions of gas-filled and solid detectors. Poppinga D; Delfs B; Meyners J; Harder D; Poppe B; Looe HK Z Med Phys; 2018 Aug; 28(3):224-235. PubMed ID: 28869164 [TBL] [Abstract][Full Text] [Related]
34. Design of a fast multileaf collimator for radiobiological optimized IMRT with scanned beams of photons, electrons, and light ions. Svensson R; Larsson S; Gudowska I; Holmberg R; Brahme A Med Phys; 2007 Mar; 34(3):877-88. PubMed ID: 17441233 [TBL] [Abstract][Full Text] [Related]
35. Correcting kernel tilting and hardening in convolution/superposition dose calculations for clinical divergent and polychromatic photon beams. Liu HH; Mackie TR; McCullough EC Med Phys; 1997 Nov; 24(11):1729-41. PubMed ID: 9394280 [TBL] [Abstract][Full Text] [Related]
36. Fast IMRT with narrow high energy scanned photon beams. Andreassen B; Strååt SJ; Holmberg R; Näfstadius P; Brahme A Med Phys; 2011 Aug; 38(8):4774-84. PubMed ID: 21928650 [TBL] [Abstract][Full Text] [Related]
37. A new approach in dose measurement and error analysis for narrow photon beams (beamlets) shaped by different multileaf collimators using a small detector. Li S; Rashid A; He S; Djajaputra D Med Phys; 2004 Jul; 31(7):2020-32. PubMed ID: 15305454 [TBL] [Abstract][Full Text] [Related]
38. Monochromatic beam characterization for Auger electron dosimetry and radiotherapy. Dugas JP; Oves SD; Sajo E; Matthews KL; Ham K; Hogstrom KR Eur J Radiol; 2008 Dec; 68(3 Suppl):S137-41. PubMed ID: 18599232 [TBL] [Abstract][Full Text] [Related]
39. Bone and mucosal dosimetry in skin radiation therapy: a Monte Carlo study using kilovoltage photon and megavoltage electron beams. Chow JC; Jiang R Phys Med Biol; 2012 Jun; 57(12):3885-99. PubMed ID: 22642985 [TBL] [Abstract][Full Text] [Related]
40. 2D convolution kernels of ionization chambers used for photon-beam dosimetry in magnetic fields: the advantage of small over large chamber dimensions. Looe HK; Delfs B; Poppinga D; Harder D; Poppe B Phys Med Biol; 2018 Mar; 63(7):075013. PubMed ID: 29516870 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]