These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

180 related articles for article (PubMed ID: 16989405)

  • 1. [Development of 64-channel magnetocardiography and clinical application].
    Nakai K; Fukuhiro H; Kawazoe K; Tsuboi J; Oshima Y; Kobayashi N; Niinuma H; Fukushima A; Suwabe A
    Rinsho Byori; 2006 Aug; 54(8):844-9. PubMed ID: 16989405
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Development of three-dimensional analysis of current density distribution by 64-ch magentocardiography and clinical application].
    Nakai K; Kazui T; Okabayashi H; Hayashi R; Fukushima A; Suwabe A
    Rinsho Byori; 2008 Dec; 56(12):1118-24. PubMed ID: 19175077
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Detection of atrial arrhythmia in superconducting quantum interference device magnetocardiography; preliminary result of a totally-noninvasive localization method for atrial current mapping.
    Kim D; Kim K; Lee YH; Ahn H
    Interact Cardiovasc Thorac Surg; 2007 Jun; 6(3):274-9. PubMed ID: 17669841
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Diagnostic value of magnetocardiography in coronary artery disease and cardiac arrhythmias: a review of clinical data.
    Kwong JS; Leithäuser B; Park JW; Yu CM
    Int J Cardiol; 2013 Sep; 167(5):1835-42. PubMed ID: 23336954
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Construction of a three-dimensional outline of the heart and conduction pathway by means of a 64-channel magnetocardiogram in patients with atrial flutter and fibrillation.
    Nakai K; Kawazoe K; Izumoto H; Tsuboi J; Oshima Y; Oka T; Yoshioka K; Shozushima M; Suwabe A; Itoh M; Kobayashi K; Shimizu T; Yoshizawa M
    Int J Cardiovasc Imaging; 2005 Oct; 21(5):555-61; discussion 563-4. PubMed ID: 16175446
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Detection of non-ST-elevation myocardial infarction using magnetocardiogram: new information from spatiotemporal electrical activation map.
    Kyoon Lim H; Kim K; Lee YH; Chung N
    Ann Med; 2009; 41(7):533-46. PubMed ID: 19626486
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Magnetocardiography provides non-invasive three-dimensional electroanatomical imaging of cardiac electrophysiology.
    Fenici R; Brisinda D
    Anadolu Kardiyol Derg; 2007 Jul; 7 Suppl 1():23-8. PubMed ID: 17584673
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Fetal magnetocardiography].
    Hosono T
    Rinsho Byori; 2006 May; 54(5):477-85. PubMed ID: 16789418
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Noninvasive classification of ventricular preexcitation with unshielded magnetocardiography and transesophageal atrial pacing and follow-up.
    Brisinda D; Fenici R
    Pacing Clin Electrophysiol; 2007 Jan; 30 Suppl 1():S151-5. PubMed ID: 17302694
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Magnetocardiographic diagnosis for myocardial ischemia and arrhythmias].
    Watanabe S; Yamaguchi I
    Rinsho Byori; 2006 May; 54(5):466-76. PubMed ID: 16789417
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Can magnetocardiography detect patients with non-ST-segment elevation myocardial infarction?
    Lim HK; Chung N; Kim K; Ko YG; Kwon H; Lee YH; Kim JM; Joung B; Kim JB; Yu KK; Cho JR; Kim IS; Park YK
    Ann Med; 2007; 39(8):617-27. PubMed ID: 17852033
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Usefulness of magnetocardiogram to detect unstable angina pectoris and non-ST elevation myocardial infarction.
    Lim HK; Kwon H; Chung N; Ko YG; Kim JM; Kim IS; Park YK
    Am J Cardiol; 2009 Feb; 103(4):448-54. PubMed ID: 19195500
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fetal magnetocardiography (fMCG): moving forward in the establishment of clinical reference data by advanced biomagnetic instrumentation and analysis.
    Kiefer-Schmidt I; Lim M; Wacker-Gussmann A; Ortiz E; Abele H; Kagan KO; Kaulitz R; Wallwiener D; Preissl H
    J Perinat Med; 2012 Feb; 40(3):277-86. PubMed ID: 22505507
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Three-dimensional recovery time dispersion map by 64-channel magnetocardiography may demonstrate the location of a myocardial injury and heterogeneity of repolarization.
    Nakai K; Izumoto H; Kawazoe K; Tsuboi J; Fukuhiro Y; Oka T; Yoshioka K; Shozushima M; Itoh M; Suwabe A; Yoshizawa M
    Int J Cardiovasc Imaging; 2006; 22(3-4):573-80. PubMed ID: 16307313
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Non-invasive detection of conduction pathways to left atrium using magnetocardiography: validation by intra-cardiac electroanatomic mapping.
    Jurkko R; Mäntynen V; Tapanainen JM; Montonen J; Väänänen H; Parikka H; Toivonen L
    Europace; 2009 Feb; 11(2):169-77. PubMed ID: 19074785
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of magnetocardiography and electrocardiography: a study of automatic measurement of dispersion of ventricular repolarization.
    Smith FE; Langley P; van Leeuwen P; Hailer B; Trahms L; Steinhoff U; Bourke JP; Murray A
    Europace; 2006 Oct; 8(10):887-93. PubMed ID: 16837488
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Characterization of fetal arrhythmias by means of fetal magnetocardiography in three cases of difficult ultrasonographic imaging.
    Comani S; Liberati M; Mantini D; Gabriele E; Brisinda D; Di Luzio S; Fenici R; Romani GL
    Pacing Clin Electrophysiol; 2004 Dec; 27(12):1647-55. PubMed ID: 15613129
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Unshielded fetal magnetocardiography system using two-dimensional gradiometers.
    Seki Y; Kandori A; Kumagai Y; Ohnuma M; Ishiyama A; Ishii T; Nakamura Y; Horigome H; Chiba T
    Rev Sci Instrum; 2008 Mar; 79(3):036106. PubMed ID: 18377051
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Quantitative evaluation of signal integrity for magnetocardiography.
    Zhang S; Wang Y; Wang H; Jiang S; Xie X
    Phys Med Biol; 2009 Aug; 54(15):4793-802. PubMed ID: 19622849
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Development and application of an automated extraction algorithm for fetal magnetocardiography - normal data and arrhythmia detection.
    Stingl K; Paulsen H; Weiss M; Preissl H; Abele H; Goelz R; Wacker-Gussmann A
    J Perinat Med; 2013 Nov; 41(6):725-34. PubMed ID: 23828424
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.