These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
122 related articles for article (PubMed ID: 1699276)
1. Mass spectrometry and its use in tandem with laser spectroscopy. Grant ER; Cooks RG Science; 1990 Oct; 250(4977):61-8. PubMed ID: 1699276 [TBL] [Abstract][Full Text] [Related]
2. Tandem mass spectrometry in quadrupole ion trap and ion cyclotron resonance mass spectrometers. Payne AH; Glish GL Methods Enzymol; 2005; 402():109-48. PubMed ID: 16401508 [TBL] [Abstract][Full Text] [Related]
3. Dissymmetry effects on the laser spectroscopy of supersonically expanded rare gas/chiral arene heteroclusters. Filippi A; Giardini A; Marcantoni E; Paladini A; Piccirillo S; Renzi G; Rondino F; Roselli G; Satta M; Speranza M Phys Chem Chem Phys; 2007 Apr; 9(14):1676-9. PubMed ID: 17396178 [TBL] [Abstract][Full Text] [Related]
5. Laser desorption studies of high mass biomolecules in Fourier-transform ion cyclotron resonance mass spectrometry. Solouki T; Russell DH Proc Natl Acad Sci U S A; 1992 Jul; 89(13):5701-4. PubMed ID: 1378614 [TBL] [Abstract][Full Text] [Related]
6. Vibrational spectroscopy of bare and solvated ionic complexes of biological relevance. Polfer NC; Oomens J Mass Spectrom Rev; 2009; 28(3):468-94. PubMed ID: 19241457 [TBL] [Abstract][Full Text] [Related]
7. Hybrid triple quadrupole-linear ion trap mass spectrometry in fragmentation mechanism studies: application to structure elucidation of buspirone and one of its metabolites. Zhang MY; Pace N; Kerns EH; Kleintop T; Kagan N; Sakuma T J Mass Spectrom; 2005 Aug; 40(8):1017-29. PubMed ID: 15934027 [TBL] [Abstract][Full Text] [Related]
8. Trade-off between high sensitivity and increased potential for false positive peptide sequence matches using a two-dimensional linear ion trap for tandem mass spectrometry-based proteomics. Xie H; Griffin TJ J Proteome Res; 2006 Apr; 5(4):1003-9. PubMed ID: 16602709 [TBL] [Abstract][Full Text] [Related]
9. Laser-induced dissociation of singly protonated peptides at 193 and 266 nm within a hybrid linear ion trap mass spectrometer. Lai CK; Ng DC; Pang HF; Le Blanc JC; Hager JW; Fang DC; Cheung AS; Chu IK Rapid Commun Mass Spectrom; 2013 May; 27(10):1119-27. PubMed ID: 23592116 [TBL] [Abstract][Full Text] [Related]
10. Comparison of triple quadrupole, hybrid linear ion trap triple quadrupole, time-of-flight and LTQ-Orbitrap mass spectrometers in drug discovery phase metabolite screening and identification in vitro--amitriptyline and verapamil as model compounds. Rousu T; Herttuainen J; Tolonen A Rapid Commun Mass Spectrom; 2010 Apr; 24(7):939-57. PubMed ID: 20209667 [TBL] [Abstract][Full Text] [Related]
11. Activation of large ions in FT-ICR mass spectrometry. Laskin J; Futrell JH Mass Spectrom Rev; 2005; 24(2):135-67. PubMed ID: 15389858 [TBL] [Abstract][Full Text] [Related]
12. The combination of laser photodissociation, action spectroscopy, and mass spectrometry to identify and separate isomers. Marlton SJP; Trevitt AJ Chem Commun (Camb); 2022 Aug; 58(68):9451-9467. PubMed ID: 35938922 [TBL] [Abstract][Full Text] [Related]
13. Towards a universal product ion mass spectral library - reproducibility of product ion spectra across eleven different mass spectrometers. Hopley C; Bristow T; Lubben A; Simpson A; Bull E; Klagkou K; Herniman J; Langley J Rapid Commun Mass Spectrom; 2008 Jun; 22(12):1779-86. PubMed ID: 18470872 [TBL] [Abstract][Full Text] [Related]
14. Structure elucidation of four related substances in gramicidin with liquid chromatography/mass spectrometry. Govaerts C; Orwa J; Van Schepdael A; Roets E; Hoogmartens J Rapid Commun Mass Spectrom; 2001; 15(2):128-34. PubMed ID: 11180541 [TBL] [Abstract][Full Text] [Related]
15. Creation and comparison of MS/MS spectral libraries using quadrupole ion trap and triple-quadrupole mass spectrometers. Josephs JL; Sanders M Rapid Commun Mass Spectrom; 2004; 18(7):743-59. PubMed ID: 15052556 [TBL] [Abstract][Full Text] [Related]
16. Broad-Spectrum Drug Screening Using Liquid Chromatography-Hybrid Triple-Quadrupole Linear Ion Trap Mass Spectrometry. Stone J Methods Mol Biol; 2016; 1383():133-51. PubMed ID: 26660183 [TBL] [Abstract][Full Text] [Related]
17. Comparison of three types of mass spectrometers for HPLC/MS analysis of perfluoroalkylated substances and fluorotelomer alcohols. Berger U; Langlois I; Oehme M; Kallenborn R Eur J Mass Spectrom (Chichester); 2004; 10(5):579-88. PubMed ID: 15531790 [TBL] [Abstract][Full Text] [Related]
18. Orthogonal time-of-flight secondary ion mass spectrometric analysis of peptides using large gold clusters as primary ions. Tempez A; Schultz JA; Della-Negra S; Depauw J; Jacquet D; Novikov A; Lebeyec Y; Pautrat M; Caroff M; Ugarov M; Bensaoula H; Gonin M; Fuhrer K; Woods A Rapid Commun Mass Spectrom; 2004; 18(4):371-6. PubMed ID: 14966842 [TBL] [Abstract][Full Text] [Related]
19. Determination of glycopeptide structures by multistage mass spectrometry with low-energy collision-induced dissociation: comparison of electrospray ionization quadrupole ion trap and matrix-assisted laser desorption/ionization quadrupole ion trap reflectron time-of-flight approaches. Demelbauer UM; Zehl M; Plematl A; Allmaier G; Rizzi A Rapid Commun Mass Spectrom; 2004; 18(14):1575-82. PubMed ID: 15282782 [TBL] [Abstract][Full Text] [Related]
20. Cryogenic methods for the spectroscopy of large, biomolecular ions. Rizzo TR; Boyarkin OV Top Curr Chem; 2015; 364():43-97. PubMed ID: 25467534 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]