758 related articles for article (PubMed ID: 16997419)
1. Emergency department sonographic measurement of optic nerve sheath diameter to detect findings of increased intracranial pressure in adult head injury patients.
Tayal VS; Neulander M; Norton HJ; Foster T; Saunders T; Blaivas M
Ann Emerg Med; 2007 Apr; 49(4):508-14. PubMed ID: 16997419
[TBL] [Abstract][Full Text] [Related]
2. Can ocular ultrasound predict intracranial hypertension? A pilot diagnostic accuracy evaluation in a UK emergency department.
Qayyum H; Ramlakhan S
Eur J Emerg Med; 2013 Apr; 20(2):91-7. PubMed ID: 22327166
[TBL] [Abstract][Full Text] [Related]
3. Elevated intracranial pressure detected by bedside emergency ultrasonography of the optic nerve sheath.
Blaivas M; Theodoro D; Sierzenski PR
Acad Emerg Med; 2003 Apr; 10(4):376-81. PubMed ID: 12670853
[TBL] [Abstract][Full Text] [Related]
4. Utility of optic nerve ultrasonography in head injury.
Goel RS; Goyal NK; Dharap SB; Kumar M; Gore MA
Injury; 2008 May; 39(5):519-24. PubMed ID: 18325519
[TBL] [Abstract][Full Text] [Related]
5. Bedside sonographic measurement of optic nerve sheath diameter as a predictor of increased intracranial pressure in children.
Le A; Hoehn ME; Smith ME; Spentzas T; Schlappy D; Pershad J
Ann Emerg Med; 2009 Jun; 53(6):785-91. PubMed ID: 19167786
[TBL] [Abstract][Full Text] [Related]
6. Bedside sonographic measurement of optic nerve sheath diameter as a predictor of intracranial pressure in ED.
Komut E; Kozacı N; Sönmez BM; Yılmaz F; Komut S; Yıldırım ZN; Beydilli İ; Yel C
Am J Emerg Med; 2016 Jun; 34(6):963-7. PubMed ID: 26944107
[TBL] [Abstract][Full Text] [Related]
7. Optic nerve sheath diameter measurement: a means of detecting raised ICP in adult traumatic and non-traumatic neurosurgical patients.
Raffiz M; Abdullah JM
Am J Emerg Med; 2017 Jan; 35(1):150-153. PubMed ID: 27852525
[TBL] [Abstract][Full Text] [Related]
8. Ultrasonographic measured optic nerve sheath diameter as an accurate and quick monitor for changes in intracranial pressure.
Maissan IM; Dirven PJ; Haitsma IK; Hoeks SE; Gommers D; Stolker RJ
J Neurosurg; 2015 Sep; 123(3):743-7. PubMed ID: 25955869
[TBL] [Abstract][Full Text] [Related]
9. Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure.
Kimberly HH; Shah S; Marill K; Noble V
Acad Emerg Med; 2008 Feb; 15(2):201-4. PubMed ID: 18275454
[TBL] [Abstract][Full Text] [Related]
10. Ultrasound measurement of optic nerve sheath diameter in patients with a clinical suspicion of raised intracranial pressure.
Major R; Girling S; Boyle A
Emerg Med J; 2011 Aug; 28(8):679-81. PubMed ID: 20713366
[TBL] [Abstract][Full Text] [Related]
11. Role of serial ultrasonic optic nerve sheath diameter monitoring in head injury.
Thotakura AK; Marabathina NR; Danaboyina AR; Mareddy RR
Neurochirurgie; 2017 Dec; 63(6):444-448. PubMed ID: 29122307
[TBL] [Abstract][Full Text] [Related]
12. Bedside Optic Nerve Sheath Diameter Assessment in the Identification of Increased Intracranial Pressure in Suspected Idiopathic Intracranial Hypertension.
Irazuzta JE; Brown ME; Akhtar J
Pediatr Neurol; 2016 Jan; 54():35-8. PubMed ID: 26481981
[TBL] [Abstract][Full Text] [Related]
13. The role of sonographic optic nerve sheath diameter measurements in pediatric head trauma.
Şık N; Ulusoy E; Çitlenbik H; Öztürk A; Er A; Yılmaz D; Duman M
J Ultrasound; 2022 Dec; 25(4):957-963. PubMed ID: 35396696
[TBL] [Abstract][Full Text] [Related]
14. A Prospective Study of Optic Nerve Ultrasound for the Detection of Elevated Intracranial Pressure in Severe Traumatic Brain Injury.
Agrawal D; Raghavendran K; Zhao L; Rajajee V
Crit Care Med; 2020 Dec; 48(12):e1278-e1285. PubMed ID: 33048902
[TBL] [Abstract][Full Text] [Related]
15. Comparison of ultrasonography and computed tomography for measuring optic nerve sheath diameter for the detection of elevated intracranial pressure.
Kim DY; Kim SY; Hong DY; Sung BY; Lee S; Paik JH; Jung HM
Clin Neurol Neurosurg; 2021 May; 204():106609. PubMed ID: 33813371
[TBL] [Abstract][Full Text] [Related]
16. Correlation between Invasive Intracranial Pressure Monitoring and Optic Nerve Sheath Diameter in Patients with Traumatic Brain Injury.
Shrestha B; Shrestha P; Ghale P; Lakshmipathy G
Kathmandu Univ Med J (KUMJ); 2021; 19(74):221-224. PubMed ID: 34819440
[TBL] [Abstract][Full Text] [Related]
17. Optic nerve sheath diameter ultrasonography for elevated intracranial pressure detection.
Wang LJ; Chen HX; Chen Y; Yu ZY; Xing YQ
Ann Clin Transl Neurol; 2020 May; 7(5):865-868. PubMed ID: 32383326
[TBL] [Abstract][Full Text] [Related]
18. The value of bedside ocular ultrasound assessment of optic nerve sheath diameter in the detection of increased intracranial pressure in patients presenting to the emergency room with headache.
Canakci Y; Koksal O; Durak VA
Niger J Clin Pract; 2018 Jun; 21(6):778-782. PubMed ID: 29888727
[TBL] [Abstract][Full Text] [Related]
19. Optic nerve sheath diameter and lumbar puncture opening pressure in nontrauma patients suspected of elevated intracranial pressure.
Caffery TS; Perret JN; Musso MW; Jones GN
Am J Emerg Med; 2014 Dec; 32(12):1513-5. PubMed ID: 25284485
[TBL] [Abstract][Full Text] [Related]
20. Bedside Optic Nerve Ultrasonography for Diagnosing Increased Intracranial Pressure: A Systematic Review and Meta-analysis.
Koziarz A; Sne N; Kegel F; Nath S; Badhiwala JH; Nassiri F; Mansouri A; Yang K; Zhou Q; Rice T; Faidi S; Passos E; Healey A; Banfield L; Mensour M; Kirkpatrick AW; Nassar A; Fehlings MG; Hawryluk GWJ; Almenawer SA
Ann Intern Med; 2019 Dec; 171(12):896-905. PubMed ID: 31739316
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]