These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 1700076)

  • 21. [Long-term electrocardiography: value and reliability of various systems].
    Bethge KP; Gonska BD
    Z Kardiol; 1985 Oct; 74(10):567-79. PubMed ID: 2416139
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Arrhythmias documented by 24 hour continuous electrocardiographic monitoring in 50 male medical students without apparent heart disease.
    Brodsky M; Wu D; Denes P; Kanakis C; Rosen KM
    Am J Cardiol; 1977 Mar; 39(3):390-5. PubMed ID: 65912
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Cardiovascular complaints. Correlation with cardiac arrhythmias on 24-hour electrocardiographic monitoring.
    Zeldis SM; Levine BJ; Michelson EL; Morganroth J
    Chest; 1980 Sep; 78(3):456-61. PubMed ID: 7418465
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Long-term prognostic significance of ambulatory electrocardiographic findings in apparently healthy subjects greater than or equal to 60 years of age.
    Fleg JL; Kennedy HL
    Am J Cardiol; 1992 Sep; 70(7):748-51. PubMed ID: 1381549
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A real-time cardiac arrhythmia classification system with wearable sensor networks.
    Hu S; Wei H; Chen Y; Tan J
    Sensors (Basel); 2012; 12(9):12844-69. PubMed ID: 23112746
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Prognostic significance of 24 hour ambulatory electrocardiographic monitoring in patients with hypertrophic cardiomyopathy: a prospective study.
    Maron BJ; Savage DD; Wolfson JK; Epstein SE
    Am J Cardiol; 1981 Aug; 48(2):252-7. PubMed ID: 7196685
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Clinical exploration of arrhythmias].
    Bañuelos F; Vázquez C; Cárdenas M; Fishleder B
    Arch Inst Cardiol Mex; 1970; 40(3):329-47. PubMed ID: 4097736
    [No Abstract]   [Full Text] [Related]  

  • 28. [Usefullness of continuous electrocardiographic recording in the ambulatory patient].
    Van Durme JP
    Arch Mal Coeur Vaiss; 1974 Dec; 67(12):1465-71. PubMed ID: 4143102
    [No Abstract]   [Full Text] [Related]  

  • 29. A piecewise geometric analysis method for real-time ambulatory ECG detection.
    Zhou HY; Li J; Zuo DC; Hou KM; Vaulx Cd
    Technol Health Care; 2015; 23 Suppl 2():S335-42. PubMed ID: 26410500
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Usefulness of simultaneous ambulatory electrocardiographic and blood pressure monitoring in detecting myocardial ischemia in patients > 70 years of age with systemic hypertension.
    Trenkwalder P; Dobrindt R; Plaschke M; Lydtin H
    Am J Cardiol; 1993 Oct; 72(12):927-31. PubMed ID: 7692716
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Validation of a discontinuously recording, digital long-term ECG system (Siemens-Sirecust 802/850) using a single beat analysis].
    Zehender M; Meinertz T; Geibel A; Hohnloser S; Just H
    Z Kardiol; 1989 Jan; 78(1):4-13. PubMed ID: 2466381
    [TBL] [Abstract][Full Text] [Related]  

  • 32. PocketECG: a new continuous and real-time ambulatory arrhythmia diagnostic method.
    Dziubiński M
    Cardiol J; 2011; 18(4):454-60. PubMed ID: 21769831
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Ventricular extrasystoles, ventricular tachycardia, and ventricular fibrillation: clinical-electrocardiographic considerations.
    Schamroth L
    Prog Cardiovasc Dis; 1980; 23(1):13-32. PubMed ID: 6156474
    [No Abstract]   [Full Text] [Related]  

  • 34. [The electrocardiogram. Indications and interpretation].
    Moubarak G; Lacotte J; Leenhardt A
    Rev Prat; 2008 Nov; 58(17):1953-62. PubMed ID: 19157214
    [No Abstract]   [Full Text] [Related]  

  • 35. Computer diagnosis of supraventricular and ventricular arrhythmias. A new esophageal technique.
    Jenkins JM; Wu D; Arzbaecher RC
    Circulation; 1979 Nov; 60(5):977-87. PubMed ID: 487556
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Holter monitoring in patients with focal cerebral ischaemic attacks (author's transl)].
    Tonet JL; Frank R; Ducardonnet A; Fillette F; Fontaine G; Komajda M; Thomas D; Bousser MG; Grosgogeat Y
    Nouv Presse Med; 1981 Jul 11-25; 10(30):2491-4. PubMed ID: 6167934
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Low-Power Long-Term Ambulatory Electrocardiography Monitor of Three Leads with Beat-to-Beat Heart Rate Measurement in Real Time.
    Martínez-Suárez F; García-Limón JA; Baños-Bautista JE; Alvarado-Serrano C; Casas O
    Sensors (Basel); 2023 Oct; 23(19):. PubMed ID: 37837133
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Primary vasospastic angina pectoris: relations between manifestations of ischemia and presence of ventricular arrhythmia].
    Kachalkov DV; Ananich VA
    Kardiologiia; 1989 Dec; 29(12):81-4. PubMed ID: 2483735
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Cardiac arrhythmias in active elderly persons--age dependence of heart rate and arrhythmias].
    Dietz A; Walter J; Bracharz H; Bracharz M; Unkelbach S; Franke H
    Z Kardiol; 1987 Feb; 76(2):86-94. PubMed ID: 2437715
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Computer recognition of cardiac arrhythmias.
    Caceres CA
    Cardiovasc Clin; 1970; 2(2):295-306. PubMed ID: 4131128
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.