These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

207 related articles for article (PubMed ID: 1700383)

  • 21. Suppression of ventricular output by noise in the atrial channel in a dual chamber pacemaker.
    Ben-Zur UM; Kahn S; Gross JN; Platt SB; Goodfriend MA; Furman S
    Pacing Clin Electrophysiol; 1995 Aug; 18(8):1586-8. PubMed ID: 7479181
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Single lead DDD system: a comparative evaluation of unipolar, bipolar, and overlapping biphasic stimulation and the effects of right atrial floating electrode location on atrial pacing and sensing thresholds.
    Tse HF; Lau CP; Leung SK; Leung Z; Mehta N
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):1758-63. PubMed ID: 8945035
    [TBL] [Abstract][Full Text] [Related]  

  • 23. P wave oversensing in a unipolar VVI pacemaker.
    van Gelder BM; Bracke FA; El Gamal MI
    Pacing Clin Electrophysiol; 1995 Feb; 18(2):370-3. PubMed ID: 7731887
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Telemetry guided pacemaker programming: impact of output amplitude and the use of low threshold leads on projected pacemaker longevity.
    Schwaab B; Fröhlig G; Schwerdt H; Heisel A; Berg M; Schieffer H
    Pacing Clin Electrophysiol; 1998 Nov; 21(11 Pt 1):2055-63. PubMed ID: 9826856
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Electrophysiological properties of a new permanent endocardial lead for uni- and bipolar pacing.
    Breivik K; Engedal H; Ohm OJ
    Pacing Clin Electrophysiol; 1982 Mar; 5(2):268-74. PubMed ID: 6176968
    [TBL] [Abstract][Full Text] [Related]  

  • 26. How pacemakers work and simple programming: a primer for the non-electrophysiologist.
    Chiu-Man C
    Cardiol Young; 2017 Jan; 27(S1):S115-S120. PubMed ID: 28084968
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Direct recording of concealed ventricular extrasystoles producing pacer inhibition.
    Bowers M; Berger M
    J Cardiovasc Electrophysiol; 2013 Oct; 24(10):1179-82. PubMed ID: 23600888
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Uni- and bipolar 2-chamber stimulation with a DDD system of programmable polarity].
    Peters W; Greve H; Gülker H; Heuer H
    Z Kardiol; 1988 Apr; 77(4):201-7. PubMed ID: 3388935
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Comparison of unipolar and bipolar active fixation atrial pacing leads.
    Kay GN; Epstein AE; Plumb VJ
    Pacing Clin Electrophysiol; 1988 May; 11(5):544-9. PubMed ID: 2456532
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Inappropriate discharge by an implantable cardioverter defibrillator: recognition of myopotential sensing using telemetered intracardiac electrograms.
    Sandler MJ; Kutalek SP
    Pacing Clin Electrophysiol; 1994 Apr; 17(4 Pt 1):665-71. PubMed ID: 7516548
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Single-lead VDD pacing system.
    Varriale P; Pilla AG; Tekriwal M
    Pacing Clin Electrophysiol; 1990 Jun; 13(6):757-66. PubMed ID: 1695356
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The use of implantable sensors for the control of pacemaker mediated tachycardias: a comparative evaluation between minute ventilation sensing and acceleration sensing dual chamber rate adaptive pacemakers.
    Lau CP; Tai YT; Fong PC; Li JP; Chung FL; Song S
    Pacing Clin Electrophysiol; 1992 Jan; 15(1):34-44. PubMed ID: 1370998
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Atrial synchronous ventricular inhibited (VDD) pacemaker-mediated arrhythmia due to atrial undersensing and atrial lead oversensing of far-field ventricular afterpotentials or paced beats: crosstalk.
    Johnson CD
    Pacing Clin Electrophysiol; 1986 Sep; 9(5):710-9. PubMed ID: 2429278
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Evolution of atrial signals from a single lead VDD pacemaker. AddVent European Multicentre Study Group.
    Papouchado M; Crick JC
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):1772-6. PubMed ID: 8945038
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Orthogonal ventricular electrogram sensing.
    Goldreyer BN; Brueske R; Knudson MB; Cannom DS; Wyman MG
    Pacing Clin Electrophysiol; 1983 Jul; 6(4):761-8. PubMed ID: 6192411
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Chronic steroid-eluting lead performance: a comparison of atrial and ventricular pacing.
    Hua W; Mond HG; Strathmore N
    Pacing Clin Electrophysiol; 1997 Jan; 20(1 Pt 1):17-24. PubMed ID: 9121966
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Successful implantation of a bipolar epicardial lead and an autocapture pacemaker in a low-body-weight infant with congenital atrioventricular block: report of a case.
    Tomita Y; Imoto Y; Tominaga R; Yasui H
    Surg Today; 2000; 30(6):555-7. PubMed ID: 10883472
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Effects of internal defibrillation on an implanted pacing system with programmable polarity.
    Khoury DS; Zhu WX; Nitta J; Rizo-Patron C; Maloney JD
    Pacing Clin Electrophysiol; 1995 Jan; 18(1 Pt 2):188-93. PubMed ID: 7724397
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Medium-term follow-up and modes of failure following epicardial pacemaker implantation in young children.
    Bakhtiary F; Dzemali O; Bastanier CK; Moritz A; Kleine P
    Europace; 2007 Feb; 9(2):94-7. PubMed ID: 17227811
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Bipolar versus unipolar issues in DDD pacing.
    Baker RG; Falkenberg EN
    Pacing Clin Electrophysiol; 1984 Nov; 7(6 Pt 2):1178-82. PubMed ID: 6209655
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.