These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 17005612)

  • 1. Accurate real-time feedback of surface EMG during fMRI.
    Ganesh G; Franklin DW; Gassert R; Imamizu H; Kawato M
    J Neurophysiol; 2007 Jan; 97(1):912-20. PubMed ID: 17005612
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Robust EMG-fMRI artifact reduction for motion (FARM).
    van der Meer JN; Tijssen MA; Bour LJ; van Rootselaar AF; Nederveen AJ
    Clin Neurophysiol; 2010 May; 121(5):766-76. PubMed ID: 20117046
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Real time ECG artifact removal for myoelectric prosthesis control.
    Zhou P; Lock B; Kuiken TA
    Physiol Meas; 2007 Apr; 28(4):397-413. PubMed ID: 17395995
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Surface EMG measurements during fMRI at 3T: accurate EMG recordings after artifact correction.
    van Duinen H; Zijdewind I; Hoogduin H; Maurits N
    Neuroimage; 2005 Aug; 27(1):240-6. PubMed ID: 15878674
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A myokinetic arm model for estimating joint torque and stiffness from EMG signals during maintained posture.
    Shin D; Kim J; Koike Y
    J Neurophysiol; 2009 Jan; 101(1):387-401. PubMed ID: 19005007
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Sparse linear regression for reconstructing muscle activity from human cortical fMRI.
    Ganesh G; Burdet E; Haruno M; Kawato M
    Neuroimage; 2008 Oct; 42(4):1463-72. PubMed ID: 18634889
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Adaptive filtering for ECG rejection from surface EMG recordings.
    Marque C; Bisch C; Dantas R; Elayoubi S; Brosse V; PĂ©rot C
    J Electromyogr Kinesiol; 2005 Jun; 15(3):310-5. PubMed ID: 15763678
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Adaptation and vision change the relationship between muscle activity of the lower limbs and body movement during human balance perturbations.
    Patel M; Gomez S; Lush D; Fransson PA
    Clin Neurophysiol; 2009 Mar; 120(3):601-9. PubMed ID: 19136294
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Kinematic and EMG characteristics of simple shoulder movements with proprioception and visual feedback.
    Brindle TJ; Nitz AJ; Uhl TL; Kifer E; Shapiro R
    J Electromyogr Kinesiol; 2006 Jun; 16(3):236-49. PubMed ID: 16111896
    [TBL] [Abstract][Full Text] [Related]  

  • 10. fMRI methods for proximal upper limb joint motor testing and identification of undesired mirror movement after stroke.
    Daly JJ; Hrovat K; Pundik S; Sunshine J; Yue G
    J Neurosci Methods; 2008 Oct; 175(1):133-42. PubMed ID: 18786565
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Application of singular spectrum-based change-point analysis to EMG-onset detection.
    Vaisman L; Zariffa J; Popovic MR
    J Electromyogr Kinesiol; 2010 Aug; 20(4):750-60. PubMed ID: 20303784
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ultrahigh-frequency EEG during fMRI: pushing the limits of imaging-artifact correction.
    Freyer F; Becker R; Anami K; Curio G; Villringer A; Ritter P
    Neuroimage; 2009 Oct; 48(1):94-108. PubMed ID: 19539035
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Muscle motion and EMG activity in vibration treatment.
    Fratini A; La Gatta A; Bifulco P; Romano M; Cesarelli M
    Med Eng Phys; 2009 Nov; 31(9):1166-72. PubMed ID: 19671494
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The synergistic organization of muscle recruitment constrains visuomotor adaptation.
    de Rugy A; Hinder MR; Woolley DG; Carson RG
    J Neurophysiol; 2009 May; 101(5):2263-9. PubMed ID: 19225174
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Prediction of joint moments using a neural network model of muscle activations from EMG signals.
    Wang L; Buchanan TS
    IEEE Trans Neural Syst Rehabil Eng; 2002 Mar; 10(1):30-7. PubMed ID: 12173737
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Relevance of motion artifact in electromyography recordings during vibration treatment.
    Fratini A; Cesarelli M; Bifulco P; Romano M
    J Electromyogr Kinesiol; 2009 Aug; 19(4):710-8. PubMed ID: 18495492
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A novel technique for examining human brain activity associated with pedaling using fMRI.
    Mehta JP; Verber MD; Wieser JA; Schmit BD; Schindler-Ivens SM
    J Neurosci Methods; 2009 May; 179(2):230-9. PubMed ID: 19428532
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evoked electromyography-based closed-loop torque control in functional electrical stimulation.
    Zhang Q; Hayashibe M; Azevedo-Coste C
    IEEE Trans Biomed Eng; 2013 Aug; 60(8):2299-307. PubMed ID: 23529189
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optimal impedance control for task achievement in the presence of signal-dependent noise.
    Osu R; Kamimura N; Iwasaki H; Nakano E; Harris CM; Wada Y; Kawato M
    J Neurophysiol; 2004 Aug; 92(2):1199-215. PubMed ID: 15056685
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Test-retest reliability of cardinal plane isokinetic hip torque and EMG.
    Claiborne TL; Timmons MK; Pincivero DM
    J Electromyogr Kinesiol; 2009 Oct; 19(5):e345-52. PubMed ID: 18845450
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.