These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Comparison of the published Hoffer Q formula and the Hoffer Q formula used by the IOLMaster 4.02/5.02. Marchiondi S; Goldblum D J Cataract Refract Surg; 2008 Nov; 34(11):2002. PubMed ID: 19006754 [No Abstract] [Full Text] [Related]
3. Reply to dr Haigis. Re: Errors in self-programming the Hoffer Q formula. Basu S Eye (Lond); 2007 Apr; 21(4):550. PubMed ID: 17016466 [No Abstract] [Full Text] [Related]
4. Hoffer Q formula in the IOLMaster. Dreher C J Cataract Refract Surg; 2009 Jul; 35(7):1325. PubMed ID: 19545843 [No Abstract] [Full Text] [Related]
8. Accuracy of intraocular lens power prediction using the Hoffer Q, Holladay 1, Holladay 2, and SRK/T formulas. Narváez J; Zimmerman G; Stulting RD; Chang DH J Cataract Refract Surg; 2006 Dec; 32(12):2050-3. PubMed ID: 17137982 [TBL] [Abstract][Full Text] [Related]
9. Discrepancies between intraocular lens implant power prediction formulas in pediatric patients. Eibschitz-Tsimhoni M; Tsimhoni O; Archer SM; Del Monte MA Ophthalmology; 2007 Feb; 114(2):383-6. PubMed ID: 17270686 [TBL] [Abstract][Full Text] [Related]
10. Intraocular lens power calculation and optimized constants for highly myopic eyes. Petermeier K; Gekeler F; Messias A; Spitzer MS; Haigis W; Szurman P J Cataract Refract Surg; 2009 Sep; 35(9):1575-81. PubMed ID: 19683155 [TBL] [Abstract][Full Text] [Related]
12. Meridional analysis for calculating the expected spherocylindrical refraction in eyes with toric intraocular lenses. Fam HB; Lim KL J Cataract Refract Surg; 2007 Dec; 33(12):2072-6. PubMed ID: 18053907 [TBL] [Abstract][Full Text] [Related]
13. [Comparative estimation of a new empirical formula for the calculation of the focal power of intraocular lenses in the short anteroposterior axis of the eye]. Avetisov SE; Mamikonian VR; Ivanov MN; Iusef IuN; Shevelev AIu; Voroshilova NA Vestn Oftalmol; 2008; 124(2):22-4. PubMed ID: 18488465 [TBL] [Abstract][Full Text] [Related]
14. [Experiences with the Aachen IOL computer program]. Wieder M; Hettlich A; Pleyer U Fortschr Ophthalmol; 1985; 82(4):331-3. PubMed ID: 3840449 [No Abstract] [Full Text] [Related]
15. Calculating the optimal rotation of a misaligned toric intraocular lens. Tseng SS; Ma JJ J Cataract Refract Surg; 2008 Oct; 34(10):1767-72. PubMed ID: 18812131 [TBL] [Abstract][Full Text] [Related]
16. Reply to Basu. Dreher C Eye (Lond); 2007 Nov; 21(11):1451. PubMed ID: 17828145 [No Abstract] [Full Text] [Related]
17. Simple method for accurate alignment in toric phakic and aphakic intraocular lens implantation. Ma JJ; Tseng SS J Cataract Refract Surg; 2008 Oct; 34(10):1631-6. PubMed ID: 18812110 [TBL] [Abstract][Full Text] [Related]
18. [Intraocular lens power calculation in cataract phacoemulsification after refractive surgery]. Hu BJ; Zhao SZ; Tseng P Zhonghua Yan Ke Za Zhi; 2006 Oct; 42(10):888-91. PubMed ID: 17217780 [TBL] [Abstract][Full Text] [Related]
19. [Can the scattering of differences from the target refraction be avoided?]. Janknecht P Klin Monbl Augenheilkd; 2008 Oct; 225(10):868-73. PubMed ID: 18951307 [TBL] [Abstract][Full Text] [Related]
20. No-history method of intraocular lens power calculation for cataract surgery after myopic laser in situ keratomileusis. Shammas HJ; Shammas MC J Cataract Refract Surg; 2007 Jan; 33(1):31-6. PubMed ID: 17189790 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]