1228 related articles for article (PubMed ID: 17022233)
1. Three-dimensional portal image-based dose reconstruction in a virtual phantom for rapid evaluation of IMRT plans.
Ansbacher W
Med Phys; 2006 Sep; 33(9):3369-82. PubMed ID: 17022233
[TBL] [Abstract][Full Text] [Related]
2. Clinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification.
McDermott LN; Wendling M; van Asselen B; Stroom J; Sonke JJ; van Herk M; Mijnheer BJ
Med Phys; 2006 Oct; 33(10):3921-30. PubMed ID: 17089854
[TBL] [Abstract][Full Text] [Related]
3. IMRT verification by three-dimensional dose reconstruction from portal beam measurements.
Partridge M; Ebert M; Hesse BM
Med Phys; 2002 Aug; 29(8):1847-58. PubMed ID: 12201432
[TBL] [Abstract][Full Text] [Related]
4. Three-dimensional IMRT verification with a flat-panel EPID.
Steciw S; Warkentin B; Rathee S; Fallone BG
Med Phys; 2005 Feb; 32(2):600-12. PubMed ID: 15789607
[TBL] [Abstract][Full Text] [Related]
5. The prediction of transmitted dose distributions using a 3D treatment planning system.
Reich P; Bezak E; Mohammadi M; Fog L
Australas Phys Eng Sci Med; 2006 Mar; 29(1):18-29. PubMed ID: 16623218
[TBL] [Abstract][Full Text] [Related]
6. Three-dimensional dose verification for intensity modulated radiation therapy using optical CT based polymer gel dosimetry.
Wuu CS; Xu Y
Med Phys; 2006 May; 33(5):1412-9. PubMed ID: 16752577
[TBL] [Abstract][Full Text] [Related]
7. Patient-specific dosimetry of conventional and intensity modulated radiation therapy using a novel full Monte Carlo phase space reconstruction method from electronic portal images.
Jarry G; Verhaegen F
Phys Med Biol; 2007 Apr; 52(8):2277-99. PubMed ID: 17404469
[TBL] [Abstract][Full Text] [Related]
8. Independent dosimetric calculation with inclusion of head scatter and MLC transmission for IMRT.
Yang Y; Xing L; Li JG; Palta J; Chen Y; Luxton G; Boyer A
Med Phys; 2003 Nov; 30(11):2937-47. PubMed ID: 14655941
[TBL] [Abstract][Full Text] [Related]
9. VMAT QA: measurement-guided 4D dose reconstruction on a patient.
Nelms BE; Opp D; Robinson J; Wolf TK; Zhang G; Moros E; Feygelman V
Med Phys; 2012 Jul; 39(7):4228-38. PubMed ID: 22830756
[TBL] [Abstract][Full Text] [Related]
10. A Monte Carlo based three-dimensional dose reconstruction method derived from portal dose images.
van Elmpt WJ; Nijsten SM; Schiffeleers RF; Dekker AL; Mijnheer BJ; Lambin P; Minken AW
Med Phys; 2006 Jul; 33(7):2426-34. PubMed ID: 16898445
[TBL] [Abstract][Full Text] [Related]
11. Validation of a method for in vivo 3D dose reconstruction for IMRT and VMAT treatments using on-treatment EPID images and a model-based forward-calculation algorithm.
Van Uytven E; Van Beek T; McCowan PM; Chytyk-Praznik K; Greer PB; McCurdy BM
Med Phys; 2015 Dec; 42(12):6945-54. PubMed ID: 26632050
[TBL] [Abstract][Full Text] [Related]
12. Dosimetric and radiobiological impact of dose fractionation on respiratory motion induced IMRT delivery errors: a volumetric dose measurement study.
Duan J; Shen S; Fiveash JB; Popple RA; Brezovich IA
Med Phys; 2006 May; 33(5):1380-7. PubMed ID: 16752574
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of the accuracy of 3DVH software estimates of dose to virtual ion chamber and film in composite IMRT QA.
Olch AJ
Med Phys; 2012 Jan; 39(1):81-6. PubMed ID: 22225277
[TBL] [Abstract][Full Text] [Related]
14. Pretreatment verification of IMRT absolute dose distributions using a commercial a-Si EPID.
Talamonti C; Casati M; Bucciolini M
Med Phys; 2006 Nov; 33(11):4367-78. PubMed ID: 17153415
[TBL] [Abstract][Full Text] [Related]
15. Accurate two-dimensional IMRT verification using a back-projection EPID dosimetry method.
Wendling M; Louwe RJ; McDermott LN; Sonke JJ; van Herk M; Mijnheer BJ
Med Phys; 2006 Feb; 33(2):259-73. PubMed ID: 16532930
[TBL] [Abstract][Full Text] [Related]
16. Independent monitor unit calculation for intensity modulated radiotherapy using the MIMiC multileaf collimator.
Chen Z; Xing L; Nath R
Med Phys; 2002 Sep; 29(9):2041-51. PubMed ID: 12349925
[TBL] [Abstract][Full Text] [Related]
17. Dose verification of an IMRT treatment planning system with the BEAM EGS4-based Monte Carlo code.
Francescon P; Cora S; Chiovati P
Med Phys; 2003 Feb; 30(2):144-57. PubMed ID: 12607832
[TBL] [Abstract][Full Text] [Related]
18. Patient-specific IMRT verification using independent fluence-based dose calculation software: experimental benchmarking and initial clinical experience.
Georg D; Stock M; Kroupa B; Olofsson J; Nyholm T; Ahnesjö A; Karlsson M
Phys Med Biol; 2007 Aug; 52(16):4981-92. PubMed ID: 17671348
[TBL] [Abstract][Full Text] [Related]
19. Commissioning and quality assurance of a commercial stereotactic treatment-planning system for extracranial IMRT.
Wang L; Li J; Paskalev K; Hoban P; Luo W; Chen L; McNeeley S; Price R; Ma C
J Appl Clin Med Phys; 2006; 7(1):21-34. PubMed ID: 16518314
[TBL] [Abstract][Full Text] [Related]
20. Verification of inverse planning and treatment delivery for segmental IMRT.
Bedford JL; Childs PJ; Warrington AP
J Appl Clin Med Phys; 2004; 5(2):1-17. PubMed ID: 15738908
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]