These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 17029987)

  • 1. Sources of systematic bias in hypercapnia-calibrated functional MRI estimation of oxygen metabolism.
    Chiarelli PA; Bulte DP; Piechnik S; Jezzard P
    Neuroimage; 2007 Jan; 34(1):35-43. PubMed ID: 17029987
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Flow-metabolism coupling in human visual, motor, and supplementary motor areas assessed by magnetic resonance imaging.
    Chiarelli PA; Bulte DP; Gallichan D; Piechnik SK; Wise R; Jezzard P
    Magn Reson Med; 2007 Mar; 57(3):538-47. PubMed ID: 17326178
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Caffeine-induced uncoupling of cerebral blood flow and oxygen metabolism: a calibrated BOLD fMRI study.
    Perthen JE; Lansing AE; Liau J; Liu TT; Buxton RB
    Neuroimage; 2008 Mar; 40(1):237-47. PubMed ID: 18191583
    [TBL] [Abstract][Full Text] [Related]  

  • 4. High-resolution CMR(O2) mapping in rat cortex: a multiparametric approach to calibration of BOLD image contrast at 7 Tesla.
    Kida I; Kennan RP; Rothman DL; Behar KL; Hyder F
    J Cereb Blood Flow Metab; 2000 May; 20(5):847-60. PubMed ID: 10826536
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantitative functional imaging of the brain: towards mapping neuronal activity by BOLD fMRI.
    Hyder F; Kida I; Behar KL; Kennan RP; Maciejewski PK; Rothman DL
    NMR Biomed; 2001; 14(7-8):413-31. PubMed ID: 11746934
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reproducibility of BOLD, perfusion, and CMRO2 measurements with calibrated-BOLD fMRI.
    Leontiev O; Buxton RB
    Neuroimage; 2007 Mar; 35(1):175-84. PubMed ID: 17208013
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The impact of inspired oxygen levels on calibrated fMRI measurements of M, OEF and resting CMRO2 using combined hypercapnia and hyperoxia.
    Lajoie I; Tancredi FB; Hoge RD
    PLoS One; 2017; 12(3):e0174932. PubMed ID: 28362834
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cerebrovascular reactivity measured with arterial spin labeling and blood oxygen level dependent techniques.
    Zhou Y; Rodgers ZB; Kuo AH
    Magn Reson Imaging; 2015 Jun; 33(5):566-76. PubMed ID: 25708263
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Measurement of OEF and absolute CMRO2: MRI-based methods using interleaved and combined hypercapnia and hyperoxia.
    Wise RG; Harris AD; Stone AJ; Murphy K
    Neuroimage; 2013 Dec; 83():135-47. PubMed ID: 23769703
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Calibrated bold fMRI with an optimized ASL-BOLD dual-acquisition sequence.
    Fernández-Seara MA; Rodgers ZB; Englund EK; Wehrli FW
    Neuroimage; 2016 Nov; 142():474-482. PubMed ID: 27502047
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Calibrated fMRI for dynamic mapping of CMRO
    Englund EK; Fernández-Seara MA; Rodríguez-Soto AE; Lee H; Rodgers ZB; Vidorreta M; Detre JA; Wehrli FW
    J Cereb Blood Flow Metab; 2020 Jul; 40(7):1501-1516. PubMed ID: 31394960
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Improved fMRI calibration: precisely controlled hyperoxic versus hypercapnic stimuli.
    Mark CI; Fisher JA; Pike GB
    Neuroimage; 2011 Jan; 54(2):1102-11. PubMed ID: 20828623
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A novel Bayesian approach to accounting for uncertainty in fMRI-derived estimates of cerebral oxygen metabolism fluctuations.
    Simon AB; Dubowitz DJ; Blockley NP; Buxton RB
    Neuroimage; 2016 Apr; 129():198-213. PubMed ID: 26790354
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Using carbogen for calibrated fMRI at 7Tesla: comparison of direct and modelled estimation of the M parameter.
    Krieger SN; Ivanov D; Huber L; Roggenhofer E; Sehm B; Turner R; Egan GF; Gauthier CJ
    Neuroimage; 2014 Jan; 84():605-14. PubMed ID: 24071526
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Investigation of BOLD signal dependence on cerebral blood flow and oxygen consumption: the deoxyhemoglobin dilution model.
    Hoge RD; Atkinson J; Gill B; Crelier GR; Marrett S; Pike GB
    Magn Reson Med; 1999 Nov; 42(5):849-63. PubMed ID: 10542343
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Validation of the hypercapnic calibrated fMRI method using DOT-fMRI fusion imaging.
    Yücel MA; Evans KC; Selb J; Huppert TJ; Boas DA; Gagnon L
    Neuroimage; 2014 Nov; 102 Pt 2(0 2):729-35. PubMed ID: 25196509
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Inter-subject variability in hypercapnic normalization of the BOLD fMRI response.
    Liau J; Liu TT
    Neuroimage; 2009 Apr; 45(2):420-30. PubMed ID: 19111622
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Application of calibrated fMRI in Alzheimer's disease.
    Lajoie I; Nugent S; Debacker C; Dyson K; Tancredi FB; Badhwar A; Belleville S; Deschaintre Y; Bellec P; Doyon J; Bocti C; Gauthier S; Arnold D; Kergoat MJ; Chertkow H; Monchi O; Hoge RD
    Neuroimage Clin; 2017; 15():348-358. PubMed ID: 28560160
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effects of hypoxia, hyperoxia, and hypercapnia on baseline and stimulus-evoked BOLD, CBF, and CMRO2 in spontaneously breathing animals.
    Sicard KM; Duong TQ
    Neuroimage; 2005 Apr; 25(3):850-8. PubMed ID: 15808985
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Absolute quantification of resting oxygen metabolism and metabolic reactivity during functional activation using QUO2 MRI.
    Gauthier CJ; Desjardins-Crépeau L; Madjar C; Bherer L; Hoge RD
    Neuroimage; 2012 Nov; 63(3):1353-63. PubMed ID: 22986357
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.