155 related articles for article (PubMed ID: 17033765)
1. Minimally invasive plate osteosynthesis in the treatment of proximal humeral fracture.
Lau TW; Leung F; Chan CF; Chow SP
Int Orthop; 2007 Oct; 31(5):657-64. PubMed ID: 17033765
[TBL] [Abstract][Full Text] [Related]
2. [A comparative study on open reduction and plating osteosynthesis and minimal invasive plating osteosynthesis in treating mid-distal humeral shaft fractures].
An Z; He X; Zeng B
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2009 Jan; 23(1):41-4. PubMed ID: 19192876
[TBL] [Abstract][Full Text] [Related]
3. Minimally invasive plate osteosynthesis of humeral shaft fractures: a technique to aid fracture reduction and minimize complications.
Shin SJ; Sohn HS; Do NH
J Orthop Trauma; 2012 Oct; 26(10):585-9. PubMed ID: 22534690
[TBL] [Abstract][Full Text] [Related]
4. [Surgical treatment of humeral diaphyseal fractures].
Smejkal K; Lochman P; Dědek T; Trlica J
Acta Chir Orthop Traumatol Cech; 2014; 81(2):129-34. PubMed ID: 25105787
[TBL] [Abstract][Full Text] [Related]
5. Minimal invasive long PHILOS®-plate osteosynthesis in metadiaphyseal fractures of the proximal humerus.
Rancan M; Dietrich M; Lamdark T; Can U; Platz A
Injury; 2010 Dec; 41(12):1277-83. PubMed ID: 20696426
[TBL] [Abstract][Full Text] [Related]
6. [Minimally invasive percutaneous plate osteosynthesis technique for treatment of Neer II, III parts fracture of proximal humerus].
Jiang P; Wei P; Chen L; Xia X
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2011 Nov; 25(11):1330-4. PubMed ID: 22229187
[TBL] [Abstract][Full Text] [Related]
7. [Long PHILOS locking compression plate for treatment of proximal humerus and humeral shaft fractures].
Zhang H; Ni W; Gao S; Liang X; Zhou A
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2009 Apr; 23(4):419-22. PubMed ID: 19431978
[TBL] [Abstract][Full Text] [Related]
8. [Treatment of mid-distal humeral shaft fractures associated with radial nerve palsy using minimally invasive plating osteosynthesis technique].
An Z; Zeng B; He X; Huang P
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 May; 22(5):513-5. PubMed ID: 18630424
[TBL] [Abstract][Full Text] [Related]
9. Minimally invasive plate osteosynthesis for humeral shaft fracture: a reproducible technique with the assistance of an external fixator.
Lee HJ; Oh CW; Oh JK; Apivatthakakul T; Kim JW; Yoon JP; Lee DJ; Jung JW
Arch Orthop Trauma Surg; 2013 May; 133(5):649-57. PubMed ID: 23463256
[TBL] [Abstract][Full Text] [Related]
10. A prospective randomized study of operative treatment for noncomminuted humeral shaft fractures: conventional open plating versus minimal invasive plate osteosynthesis.
Kim JW; Oh CW; Byun YS; Kim JJ; Park KC
J Orthop Trauma; 2015 Apr; 29(4):189-94. PubMed ID: 25210833
[TBL] [Abstract][Full Text] [Related]
11. [Application of minimally invasive locking compression plate in treatment of proximal humeral fractures].
Law TW; Leung FK; Lu Y
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2009 Nov; 23(11):1282-4. PubMed ID: 19968162
[TBL] [Abstract][Full Text] [Related]
12. Early full range of shoulder and elbow motion is possible after minimally invasive plate osteosynthesis for humeral shaft fractures.
Kobayashi M; Watanabe Y; Matsushita T
J Orthop Trauma; 2010 Apr; 24(4):212-6. PubMed ID: 20335753
[TBL] [Abstract][Full Text] [Related]
13. Narrow locking compression plate vs long philos plate for minimally invasive plate osteosynthesis of spiral humerus shaft fractures.
Jeong JJ; Park SE; Lee HH; Ji JH; Park MS; Park YT
BMC Musculoskelet Disord; 2019 Aug; 20(1):381. PubMed ID: 31421675
[TBL] [Abstract][Full Text] [Related]
14. [Effectiveness comparison of two minimally invasive plate osteosynthesis techniques for proximal humeral shaft fractures].
Wang X; Sun K; Tang L; Liang B; Yin D
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2023 Feb; 37(2):147-152. PubMed ID: 36796807
[TBL] [Abstract][Full Text] [Related]
15. Danger zone for locking screw placement in minimally invasive plate osteosynthesis (MIPO) of humeral shaft fractures: a cadaveric study.
Apivatthakakul T; Patiyasikan S; Luevitoonvechkit S
Injury; 2010 Feb; 41(2):169-72. PubMed ID: 19735916
[TBL] [Abstract][Full Text] [Related]
16. Comparison between osteosynthesis with interlocking nail and minimally invasive plating for proximal- and middle-thirds of humeral shaft fractures.
Wang Y; Chen H; Wang L; Chen X; Zhi X; Cui J; Cao L
Int Orthop; 2021 Aug; 45(8):2093-2102. PubMed ID: 33184684
[TBL] [Abstract][Full Text] [Related]
17. [Comparison of effectiveness between minimally invasive plating osteosynthesis and expandable intramedullary nailing technique in treatment of middle third humeral shaft fractures].
An Z; He X; Jiang C; Song S; Zhang C
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2010 Dec; 24(12):1413-5. PubMed ID: 21261083
[TBL] [Abstract][Full Text] [Related]
18. Percutaneous helical plate fixation in humeral shaft fractures with proximal extension.
Videla-Cés M; Comas-Aguilar M; Endemaño-Lucio A; Sánchez-Navés R; Romero-Pijoan E; Videla S
Injury; 2023 Nov; 54 Suppl 6():110750. PubMed ID: 38143117
[TBL] [Abstract][Full Text] [Related]
19. Posterior minimally invasive plate osteosynthesis (MIPO) of distal third humeral shaft fractures with segmental isolation of the radial nerve.
Gallucci GL; Boretto JG; Alfie VA; Donndorff A; De Carli P
Chir Main; 2015 Oct; 34(5):221-6. PubMed ID: 26388162
[TBL] [Abstract][Full Text] [Related]
20. [Case-control study on minimally invasive plate osteosynthesis for the treatment of proximal humeurs fractures in elderly patients].
Wang JF; Song HB; Gu HJ; Ling ZD; Ma HH
Zhongguo Gu Shang; 2012 Jun; 25(6):487-9. PubMed ID: 23016385
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]