These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

56 related articles for article (PubMed ID: 1703837)

  • 1. [Personal computer-assisted "acceptable hemoglobin concentration". An example of preoperative autologous blood donation].
    Lundsgaard-Hansen P; Blauhut B; Doran JE
    Beitr Infusionsther; 1990; 26():220-5. PubMed ID: 1703837
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Is there a generally valid, minimum acceptable hemoglobin level?
    Lundsgaard-Hansen P; Doran JE; Blauhut B
    Infusionstherapie; 1989 Aug; 16(4):167-75. PubMed ID: 2807564
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Evaluation of a non-invasive hemoglobin measurement device for pre-deposited autologous blood donation].
    Matsunagai K; Saigo K; Hashimoto M; Kishimoto M; Takenokuchi M; Narita H; Ozawa T; Kumagai S
    Rinsho Byori; 2006 Nov; 54(11):1106-9. PubMed ID: 17240831
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [A comparison of autologous transfusion procedures in hip surgery].
    Lorentz A; Osswald PM; Schilling M; Jani L
    Anaesthesist; 1991 Apr; 40(4):205-13. PubMed ID: 2058822
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Combination of acute normovolemic hemodilution technique with preoperative autologous blood donation prevented allogeneic blood transfusion against 4000 g surgical blood loss in a patient undergoing left partial nephrectomy].
    Kabara S; Hirota K; Ebina T; Hashimoto H; Ishihara H; Matsuki A
    Masui; 2001 Mar; 50(3):296-8. PubMed ID: 11296446
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Mechanisms controlling the oxygen consumption in experimentally induced hypochloremic alkalosis in calves.
    Cambier C; Clerbaux T; Amory H; Detry B; Florquin S; Marville V; Frans A; Gustin P
    Vet Res; 2002; 33(6):697-708. PubMed ID: 12498570
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Effects of cardiac output on blood and tissue pH during general anesthesia with constant ventilation].
    Hayashida M; Uchida K; Komatsu K; Sato Y; Orii R; Hanaoka K
    Masui; 1998 Nov; 47(11):1290-5. PubMed ID: 9852690
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Preoperative autologous blood donation and its effects on pulmonary lobectomy].
    Hallfeldt K; Dornschneider G; Sohn M; Thetter O
    Zentralbl Chir; 1995; 120(3):228-33; discussion 233-5. PubMed ID: 7754725
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Effect of a single blood donation on ergo-spirometrically determined cardiopulmonary performance capacity of young healthy probands].
    Fritsch J; Winter UJ; Reupke I; Gitt AK; Berge PG; Hilger HH
    Z Kardiol; 1993 Jul; 82(7):425-31. PubMed ID: 8379242
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The use of autologous blood to improve exercise capacity after total hip arthroplasty: a preliminary report.
    Pilot P; Bols EM; Verburg AD; Bell CA; Moonen AF; van Os JJ; Koolen JJ; Geesink RG; Kuipers H
    Transfusion; 2006 Sep; 46(9):1484-90. PubMed ID: 16965573
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Risks and side effects of autologous transfusion].
    Blauhut B
    Beitr Infusionsther; 1991; 28():287-99. PubMed ID: 1725640
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Recombinant erythropoietin in autologous blood donation].
    von Bormann B; Weidler B; Friedrich M; von Andrian-Werburg H
    Anaesthesist; 1991 Jul; 40(7):386-90. PubMed ID: 1928712
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Intraoperative aspiration and reinfusion of autologous blood in resection of abdominal aortic aneurysms with Solcotrans plus].
    Walpoth B; Schmid R; Amport T; Rothen HU; Spaeth P; Kurt G; Stirnemann P; Nachbur B; Althaus U
    Helv Chir Acta; 1993 Jun; 59(5-6):843-8. PubMed ID: 8376151
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cardiovascular implementations of respiratory measurements.
    Van der Zee H; Verkaaik AP
    Acta Anaesthesiol Belg; 1990; 41(3):167-75. PubMed ID: 2260423
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [The present possibilities for routine use of blood-saving measures from the anesthesiologic point of view--theoretical bases and clinical practice. III. Autologous blood donation, autologous donation criteria and organizational measures].
    Singbartl G; Schleinzer W
    Anaesthesiol Reanim; 1994; 19 Suppl():18-24. PubMed ID: 8148014
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Preoperative autologous blood donation].
    Hitzler W; Bauerfeind U; Schömig-Brekner J; Mathias D
    Beitr Infusionsther; 1990; 26():235-9. PubMed ID: 1703840
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Hematologic parameters in repeated autologous blood donation].
    Roos D; Lubitz B; Maring J; Doumanis A; Wittkopf D; Kühnl P
    Beitr Infusionsther; 1990; 26():264-6. PubMed ID: 1703846
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Preoperative autologous blood donation - part I. Only two clinical parameters determine efficacy of the autologous predeposit.
    Singbartl G
    Minerva Anestesiol; 2007 Mar; 73(3):143-51. PubMed ID: 17384572
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Effectiveness of postoperative autologous blood transfusion after knee replacement surgery and influence of preoperative hemoglobin level].
    Santana M; Martínez E; Herrera E; Tatsidis P; Pérez M; Rodríguez F
    Rev Esp Anestesiol Reanim; 2005; 52(6):315-20. PubMed ID: 16038170
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Preoperative autologous blood donation and transfusion in gynecology].
    Foglia G; Corticelli A; Podestà M; Valenzano M; Rissone R; Giannini G; Valbonesi M
    Minerva Ginecol; 2000 Sep; 52(9):333-7. PubMed ID: 11189962
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 3.