277 related articles for article (PubMed ID: 17039936)
1. [The study of associated reconstruction using MV linear accelerator and cone-beam CT].
Liu ZG; Zhao J; Zhuang TG
Zhongguo Yi Liao Qi Xie Za Zhi; 2006 Jul; 30(4):271-3. PubMed ID: 17039936
[TBL] [Abstract][Full Text] [Related]
2. A three-dimensional-weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT-helical scanning.
Tang X; Hsieh J; Nilsen RA; Dutta S; Samsonov D; Hagiwara A
Phys Med Biol; 2006 Feb; 51(4):855-74. PubMed ID: 16467583
[TBL] [Abstract][Full Text] [Related]
3. A local region of interest image reconstruction via filtered backprojection for fan-beam differential phase-contrast computed tomography.
Qi Z; Chen GH
Phys Med Biol; 2007 Sep; 52(18):N417-23. PubMed ID: 17804875
[TBL] [Abstract][Full Text] [Related]
4. A rebinned backprojection-filtration algorithm for image reconstruction in helical cone-beam CT.
Yu L; Xia D; Zou Y; Sidky EY; Bian J; Pan X
Phys Med Biol; 2007 Sep; 52(18):5497-508. PubMed ID: 17804878
[TBL] [Abstract][Full Text] [Related]
5. Evaluation of accelerated iterative x-ray CT image reconstruction using floating point graphics hardware.
Kole JS; Beekman FJ
Phys Med Biol; 2006 Feb; 51(4):875-89. PubMed ID: 16467584
[TBL] [Abstract][Full Text] [Related]
6. Exact fan-beam image reconstruction algorithm for truncated projection data acquired from an asymmetric half-size detector.
Leng S; Zhuang T; Nett BE; Chen GH
Phys Med Biol; 2005 Apr; 50(8):1805-20. PubMed ID: 15815097
[TBL] [Abstract][Full Text] [Related]
7. Motion-compensated iterative cone-beam CT image reconstruction with adapted blobs as basis functions.
Isola AA; Ziegler A; Koehler T; Niessen WJ; Grass M
Phys Med Biol; 2008 Dec; 53(23):6777-97. PubMed ID: 18997267
[TBL] [Abstract][Full Text] [Related]
8. A three-dimensional weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT under a circular source trajectory.
Tang X; Hsieh J; Hagiwara A; Nilsen RA; Thibault JB; Drapkin E
Phys Med Biol; 2005 Aug; 50(16):3889-905. PubMed ID: 16077234
[TBL] [Abstract][Full Text] [Related]
9. Image reconstruction with laterally truncated projections in helical cone-beam CT: linear prediction based projection completion techniques.
Anoop KP; Rajgopal K
Comput Med Imaging Graph; 2009 Jun; 33(4):283-94. PubMed ID: 19251393
[TBL] [Abstract][Full Text] [Related]
10. [A 3-D image reconstruction algorithm based on helical CT raw data].
Huo XK; Wei S; Cheng ZY
Zhongguo Yi Liao Qi Xie Za Zhi; 2006 Jul; 30(4):284-6. PubMed ID: 17039940
[TBL] [Abstract][Full Text] [Related]
11. Effect of scatter on reconstructed image quality in cone beam computed tomography: evaluation of a scatter-reduction optimisation function.
Malusek A; Seger MM; Sandborg M; Alm Carlsson G
Radiat Prot Dosimetry; 2005; 114(1-3):337-40. PubMed ID: 15933133
[TBL] [Abstract][Full Text] [Related]
12. Tilted cone-beam reconstruction with row-wise fan-to-parallel rebinning.
Hsieh J; Tang X
Phys Med Biol; 2006 Oct; 51(20):5259-76. PubMed ID: 17019037
[TBL] [Abstract][Full Text] [Related]
13. Statistical reconstruction for x-ray computed tomography using energy-integrating detectors.
Lasio GM; Whiting BR; Williamson JF
Phys Med Biol; 2007 Apr; 52(8):2247-66. PubMed ID: 17404467
[TBL] [Abstract][Full Text] [Related]
14. Evaluation of the quantitative capability of a home-made cone-beam micro computed tomography system.
Chueh HS; Tsai WK; Fu HM; Chen JC
Comput Med Imaging Graph; 2006; 30(6-7):349-55. PubMed ID: 17067784
[TBL] [Abstract][Full Text] [Related]
15. Noise properties of chord-image reconstruction.
Xia D; Yu L; Sidky EY; Zou Y; Zuo N; Pan X
IEEE Trans Med Imaging; 2007 Oct; 26(10):1328-44. PubMed ID: 17948724
[TBL] [Abstract][Full Text] [Related]
16. Fourier-based forward and back-projectors in iterative fan-beam tomographic image reconstruction.
Zhang-O'Connor Y; Fessler JA
IEEE Trans Med Imaging; 2006 May; 25(5):582-9. PubMed ID: 16689262
[TBL] [Abstract][Full Text] [Related]
17. Three-dimensional focus of attention for iterative cone-beam micro-CT reconstruction.
Benson TM; Gregor J
Phys Med Biol; 2006 Sep; 51(18):4533-46. PubMed ID: 16953041
[TBL] [Abstract][Full Text] [Related]
18. Parallel SART algorithm of linear scan cone-beam CT for fixed pipeline.
Liu B; Zeng L
J Xray Sci Technol; 2009; 17(3):221-32. PubMed ID: 19893214
[TBL] [Abstract][Full Text] [Related]
19. Reduction of artifacts induced by misaligned geometry in cone-beam CT.
Sun Y; Hou Y; Hu J
IEEE Trans Biomed Eng; 2007 Aug; 54(8):1461-71. PubMed ID: 17694867
[TBL] [Abstract][Full Text] [Related]
20. A combination-weighted Feldkamp-based reconstruction algorithm for cone-beam CT.
Mori S; Endo M; Komatsu S; Kandatsu S; Yashiro T; Baba M
Phys Med Biol; 2006 Aug; 51(16):3953-65. PubMed ID: 16885617
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]