These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

224 related articles for article (PubMed ID: 17045874)

  • 1. Assessment by transient elastography of the viscoelastic properties of blood during clotting.
    Gennisson JL; Lerouge S; Cloutier G
    Ultrasound Med Biol; 2006 Oct; 32(10):1529-37. PubMed ID: 17045874
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of the sensitivity of an in vitro high frequency ultrasound device to monitor the coagulation process: study of the effects of heparin treatment in a murine model.
    Callé R; Rochefort GY; Desbuards N; Plag C; Antier D; Ossant F
    Ultrasound Med Biol; 2010 Feb; 36(2):295-305. PubMed ID: 20045589
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Estimating the viscoelastic modulus of a thrombus using an ultrasonic shear-wave approach.
    Huang CC; Chen PY; Shih CC
    Med Phys; 2013 Apr; 40(4):042901. PubMed ID: 23556923
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development of standard tests to examine viscoelastic properties of blood of experimental animals for pediatric mechanical support device evaluation.
    Marascalco PJ; Ritchie SP; Snyder TA; Kameneva MV
    ASAIO J; 2006; 52(5):567-74. PubMed ID: 16966861
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Molecular basis of fibrin clot elasticity.
    Lim BB; Lee EH; Sotomayor M; Schulten K
    Structure; 2008 Mar; 16(3):449-59. PubMed ID: 18294856
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Shear wave elastography quantification of blood elasticity during clotting.
    Bernal M; Gennisson JL; Flaud P; Tanter M
    Ultrasound Med Biol; 2012 Dec; 38(12):2218-28. PubMed ID: 23069137
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Three-dimensional transient and harmonic shear-wave scattering by a soft cylinder for dynamic vascular elastography.
    Henni AH; Schmitt C; Cloutier G
    J Acoust Soc Am; 2008 Oct; 124(4):2394-405. PubMed ID: 19062877
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A new method for the analysis of blood and plasma coagulation.
    Henderson NM; Thurston GB
    Biomed Sci Instrum; 1993; 29():95-102. PubMed ID: 8329642
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Coagulation monitoring: current techniques and clinical use of viscoelastic point-of-care coagulation devices.
    Ganter MT; Hofer CK
    Anesth Analg; 2008 May; 106(5):1366-75. PubMed ID: 18420846
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Characterization of blood clot viscoelasticity by dynamic ultrasound elastography and modeling of the rheological behavior.
    Schmitt C; Hadj Henni A; Cloutier G
    J Biomech; 2011 Feb; 44(4):622-9. PubMed ID: 21122863
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Chemorheological studies of the effect of heparin on the course of coagulation.
    Overholser KA; Baysinger CB; Harris TR; Deveau T
    Thromb Haemost; 1976 Apr; 35(2):447-59. PubMed ID: 989642
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography.
    Montaldo G; Tanter M; Bercoff J; Benech N; Fink M
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Mar; 56(3):489-506. PubMed ID: 19411209
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Nonlinear viscoelasticity and the thrombelastograph: 1. Studies on bovine plasma clots.
    Burghardt WR; Goldstick TK; Leneschmidt J; Kempka K
    Biorheology; 1995; 32(6):621-30. PubMed ID: 8857352
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of shear rate on propagation of blood clotting determined using microfluidics and numerical simulations.
    Runyon MK; Kastrup CJ; Johnson-Kerner BL; Ha TG; Ismagilov RF
    J Am Chem Soc; 2008 Mar; 130(11):3458-64. PubMed ID: 18302373
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dynamic and quantitative assessment of blood coagulation using optical coherence elastography.
    Xu X; Zhu J; Chen Z
    Sci Rep; 2016 Apr; 6():24294. PubMed ID: 27090437
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Effect of anticoagulants on blood viscosity].
    Schäbitz J; Petri A
    Folia Haematol Int Mag Klin Morphol Blutforsch; 1983; 110(2):301-8. PubMed ID: 6194063
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Sol-gel transition in agar-gelatin mixtures studied with transient elastography.
    Gennisson JL; Cloutier G
    IEEE Trans Ultrason Ferroelectr Freq Control; 2006 Apr; 53(4):716-23. PubMed ID: 16615575
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Elasticity and fracture strain of whole blood clots.
    Riha P; Wang X; Liao R; Stoltz JF
    Clin Hemorheol Microcirc; 1999; 21(1):45-9. PubMed ID: 10517487
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Assessing the viscoelastic properties of thrombus using a solid-sphere-based instantaneous force approach.
    Huang CC; Shih CC; Liu TY; Lee PY
    Ultrasound Med Biol; 2011 Oct; 37(10):1722-33. PubMed ID: 21821355
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Change of viscoelastic property and morphology of fibrin affected by antithrombin III and heparin: QCM-Z and AFM study.
    Jung H; Tae G; Kim YH; Johannsmann D
    Colloids Surf B Biointerfaces; 2009 Jan; 68(1):111-9. PubMed ID: 19004623
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.