These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 17047270)

  • 41. EEG and MEG: forward solutions for inverse methods.
    Mosher JC; Leahy RM; Lewis PS
    IEEE Trans Biomed Eng; 1999 Mar; 46(3):245-59. PubMed ID: 10097460
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Dipole estimation errors due to differences in modeling anisotropic conductivities in realistic head models for EEG source analysis.
    Hallez H; Vanrumste B; Van Hese P; Delputte S; Lemahieu I
    Phys Med Biol; 2008 Apr; 53(7):1877-94. PubMed ID: 18364544
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Electro-magneto-encephalography for a three-shell model: distributed current in arbitrary, spherical and ellipsoidal geometries.
    Fokas AS
    J R Soc Interface; 2009 May; 6(34):479-88. PubMed ID: 18757270
    [TBL] [Abstract][Full Text] [Related]  

  • 44. A theoretical formulation of the electrophysiological inverse problem on the sphere.
    Riera JJ; Valdés PA; Tanabe K; Kawashima R
    Phys Med Biol; 2006 Apr; 51(7):1737-58. PubMed ID: 16552101
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Integration of amplitude and phase statistics for complete artifact removal in independent components of neuromagnetic recordings.
    Dammers J; Schiek M; Boers F; Silex C; Zvyagintsev M; Pietrzyk U; Mathiak K
    IEEE Trans Biomed Eng; 2008 Oct; 55(10):2353-62. PubMed ID: 18838360
    [TBL] [Abstract][Full Text] [Related]  

  • 46. A mesostate-space model for EEG and MEG.
    Daunizeau J; Friston KJ
    Neuroimage; 2007 Oct; 38(1):67-81. PubMed ID: 17761440
    [TBL] [Abstract][Full Text] [Related]  

  • 47. [High-resolution EEG (HR-EEG) and magnetoencephalography (MEG)].
    Gavaret M; Badier JM; Chauvel P
    Neurochirurgie; 2008 May; 54(3):185-90. PubMed ID: 18417162
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Combining sparsity and rotational invariance in EEG/MEG source reconstruction.
    Haufe S; Nikulin VV; Ziehe A; Müller KR; Nolte G
    Neuroimage; 2008 Aug; 42(2):726-38. PubMed ID: 18583157
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Searching for the best model: ambiguity of inverse solutions and application to fetal magnetoencephalography.
    Vrba J; Robinson SE; McCubbin J; Lowery CL; Eswaran H; Murphy P; Preissl H
    Phys Med Biol; 2007 Feb; 52(3):757-76. PubMed ID: 17228119
    [TBL] [Abstract][Full Text] [Related]  

  • 50. On the EEG/MEG forward problem solution for distributed cortical sources.
    von Ellenrieder N; Valdés-Hernández PA; Muravchik CH
    Med Biol Eng Comput; 2009 Oct; 47(10):1083-91. PubMed ID: 19730912
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Brain activity and temporal coupling related to eye movements during REM sleep: EEG and MEG results.
    Corsi-Cabrera M; Guevara MA; del Río-Portilla Y
    Brain Res; 2008 Oct; 1235():82-91. PubMed ID: 18625213
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Human brain mapping: hemodynamic response and electrophysiology.
    Shibasaki H
    Clin Neurophysiol; 2008 Apr; 119(4):731-43. PubMed ID: 18187361
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Rapidly recomputable EEG forward models for realistic head shapes.
    Ermer JJ; Mosher JC; Baillet S; Leah RM
    Phys Med Biol; 2001 Apr; 46(4):1265-81. PubMed ID: 11324964
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Bayesian M/EEG source reconstruction with spatio-temporal priors.
    Trujillo-Barreto NJ; Aubert-Vázquez E; Penny WD
    Neuroimage; 2008 Jan; 39(1):318-35. PubMed ID: 17904869
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Large scale Kalman filtering solutions to the electrophysiological source localization problem--a MEG case study.
    Long CJ; Purdon RL; Temereanca S; Desai NU; Hämäläinen M; Brown EN
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():4532-5. PubMed ID: 17947095
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Artifact and head movement compensation in MEG.
    Medvedovsky M; Taulu S; Bikmullina R; Paetau R
    Neurol Neurophysiol Neurosci; 2007 Oct; ():4. PubMed ID: 18066426
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Improving MEG performance with additional tangential sensors.
    Nurminen J; Taulu S; Nenonen J; Helle L; Simola J; Ahonen A
    IEEE Trans Biomed Eng; 2013 Sep; 60(9):2559-66. PubMed ID: 23649129
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Magnetoencephalography-guided epilepsy surgery for children with intractable focal epilepsy: SickKids experience.
    Ochi A; Otsubo H
    Int J Psychophysiol; 2008 May; 68(2):104-10. PubMed ID: 18313780
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Variance stabilization for computing and comparing grand mean waveforms in MEG and EEG.
    Matysiak A; Kordecki W; Sielużycki C; Zacharias N; Heil P; König R
    Psychophysiology; 2013 Jul; 50(7):627-39. PubMed ID: 23577776
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Use of magnetoencephalography in the presurgical evaluation of epilepsy patients.
    Shibasaki H; Ikeda A; Nagamine T
    Clin Neurophysiol; 2007 Jul; 118(7):1438-48. PubMed ID: 17452007
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.