These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
159 related articles for article (PubMed ID: 17050589)
1. The wrap-around problem and optimal padding in the exit wave reconstruction using HRTEM images. Lin F; Chen FR; Chen Q; Tang D; Peng LM J Electron Microsc (Tokyo); 2006 Aug; 55(4):191-200. PubMed ID: 17050589 [TBL] [Abstract][Full Text] [Related]
2. Effective phase correction function for high-resolution exit wave reconstruction by a three-dimensional Fourier filtering method. Kawasaki T; Taya M; Nomaguchi T; Takai Y Ultramicroscopy; 2005 Jan; 102(2):127-39. PubMed ID: 15590136 [TBL] [Abstract][Full Text] [Related]
3. On the phase problem in electron microscopy: the relationship between structure factors, exit waves, and HREM images. Zou X Microsc Res Tech; 1999 Aug; 46(3):202-19. PubMed ID: 10420175 [TBL] [Abstract][Full Text] [Related]
4. Practical image restoration of thick biological specimens using multiple focus levels in transmission electron microscopy. Han KF; Sedat JW; Agard DA J Struct Biol; 1997 Dec; 120(3):237-44. PubMed ID: 9441929 [TBL] [Abstract][Full Text] [Related]
6. Optimal accelerating voltage for HRTEM imaging of zeolite. Yoshida K; Sasaki Y Microscopy (Oxf); 2013 Jun; 62(3):369-75. PubMed ID: 23243098 [TBL] [Abstract][Full Text] [Related]
7. Exit wave reconstructions using through focus series of HREM images. Zandbergen HW; Van Dyck D Microsc Res Tech; 2000 May; 49(3):301-23. PubMed ID: 10816270 [TBL] [Abstract][Full Text] [Related]
8. High precision measurements of atom column positions using model-based exit wave reconstruction. De Backer A; Van Aert S; Van Dyck D Ultramicroscopy; 2011; 111(9-10):1475-82. PubMed ID: 21930019 [TBL] [Abstract][Full Text] [Related]
9. Compositional analysis of mixed-cation-anion III-V semiconductor interfaces using phase retrieval high-resolution transmission electron microscopy. Mahalingam K; Eyink KG; Brown GJ; Dorsey DL; Kisielowski CF; Thust A J Microsc; 2008 Jun; 230(Pt 3):372-81. PubMed ID: 18503662 [TBL] [Abstract][Full Text] [Related]
10. High-quality virus images obtained by transmission electron microscopy and charge coupled device digital camera technology. Tiekotter KL; Ackermann HW J Virol Methods; 2009 Jul; 159(1):87-92. PubMed ID: 19442850 [TBL] [Abstract][Full Text] [Related]
11. Measurement of crystal thickness and crystal tilt from HRTEM images and a way to correct for their effects. Hovmöller S; Zou X Microsc Res Tech; 1999 Aug; 46(3):147-59. PubMed ID: 10420172 [TBL] [Abstract][Full Text] [Related]
12. Object-wave reconstruction by carbon film-based Zernike- and Hilbert-phase plate microscopy: a theoretical study not restricted to weak-phase objects. Dries M; Schultheiss K; Gamm B; Rosenauer A; Schröder RR; Gerthsen D Ultramicroscopy; 2011 Jan; 111(2):159-68. PubMed ID: 21185461 [TBL] [Abstract][Full Text] [Related]
13. IMAGE-WARP: a real-space restoration method for high-resolution STEM images using quantitative HRTEM analysis. Recnik A; Möbus G; Sturm S Ultramicroscopy; 2005 Jul; 103(4):285-301. PubMed ID: 15885433 [TBL] [Abstract][Full Text] [Related]
14. Direct exit-wave reconstruction from a single defocused image. Morgan AJ; Martin AV; D'Alfonso AJ; Putkunz CT; Allen LJ Ultramicroscopy; 2011; 111(9-10):1455-60. PubMed ID: 21930016 [TBL] [Abstract][Full Text] [Related]
15. Atomic imaging in aberration-corrected high-resolution transmission electron microscopy. Chen JH; Zandbergen HW; Dyck DV Ultramicroscopy; 2004 Jan; 98(2-4):81-97. PubMed ID: 15046789 [TBL] [Abstract][Full Text] [Related]
16. Measurement of crystal thickness and orientation from selected-area Fourier transformation of a high-resolution electron hologram. Du K; Wang YM; Lichte H; Ye HQ Micron; 2006; 37(1):67-72. PubMed ID: 16233980 [TBL] [Abstract][Full Text] [Related]
18. Imaging a dense nanodot assembly by phase retrieval from TEM images. Donnadieu P; Verdier M; Berthomé G; Mur P Ultramicroscopy; 2004 Jul; 100(1-2):79-90. PubMed ID: 15219693 [TBL] [Abstract][Full Text] [Related]
19. Fully automatic stitching and distortion correction of transmission electron microscope images. Kaynig V; Fischer B; Müller E; Buhmann JM J Struct Biol; 2010 Aug; 171(2):163-73. PubMed ID: 20450977 [TBL] [Abstract][Full Text] [Related]
20. Applying an information transmission approach to extract valence electron information from reconstructed exit waves. Xu Q; Zandbergen HW; Van Dyck D Ultramicroscopy; 2011 Jun; 111(7):912-9. PubMed ID: 21664552 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]