These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
86 related articles for article (PubMed ID: 17052646)
1. How does signal fade on photo-stimulable storage phosphor imaging plates when scanned with a delay and what is the effect on image quality? Ang DB; Angelopoulos C; Katz JO Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2006 Nov; 102(5):673-9. PubMed ID: 17052646 [TBL] [Abstract][Full Text] [Related]
2. Degradation of storage phosphor images due to scanning delay. Akdeniz BG; Gröndahl HG Dentomaxillofac Radiol; 2006 Mar; 35(2):74-7. PubMed ID: 16549432 [TBL] [Abstract][Full Text] [Related]
3. Some characteristics of solid-state and photo-stimulable phosphor detectors for intra-oral radiography. Borg E Swed Dent J Suppl; 1999; 139():i-viii, 1-67. PubMed ID: 10635104 [TBL] [Abstract][Full Text] [Related]
4. Comparison of three intra-oral storage phosphor systems using subjective image quality. Kitagawa H; Farman AG; Scheetz JP; Brown WP; Lewis J; Benefiel M; Kuroyanagi K Dentomaxillofac Radiol; 2000 Sep; 29(5):272-6. PubMed ID: 10980561 [TBL] [Abstract][Full Text] [Related]
5. Radiographic endodontic working length estimation: comparison of three digital image receptors. Athar A; Angelopoulos C; Katz JO; Williams KB; Spencer P Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2008 Oct; 106(4):604-8. PubMed ID: 18718798 [TBL] [Abstract][Full Text] [Related]
6. The effect of delayed scanning of storage phosphor plates on occlusal caries detection. Sogur E; Baksi BG; Mert A Dentomaxillofac Radiol; 2012 May; 41(4):309-15. PubMed ID: 22282506 [TBL] [Abstract][Full Text] [Related]
7. Effect of delayed scanning of storage phosphor plates. Akdeniz BG; Gröndahl HG; Kose T Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2005 May; 99(5):603-7. PubMed ID: 15829885 [TBL] [Abstract][Full Text] [Related]
8. What happens if you delay scanning Digora phosphor storage plates (PSPs) for up to 4 hours? Martins MG; Whaites EJ; Ambrosano GM; Haiter Neto F Dentomaxillofac Radiol; 2006 May; 35(3):143-6. PubMed ID: 16618845 [TBL] [Abstract][Full Text] [Related]
10. Comments on noise and resolution of the DenOptix radiography system. Couture RA Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2003 Jun; 95(6):746-51. PubMed ID: 12789159 [TBL] [Abstract][Full Text] [Related]
11. Analysis of digital images acquired using different phosphor storage plates (PSPs) subjected to varying reading times and storage conditions. Martins MG; Haiter Neto F; Whaites EJ Dentomaxillofac Radiol; 2003 May; 32(3):186-90. PubMed ID: 12917285 [TBL] [Abstract][Full Text] [Related]
12. Reproducibility of pixel values for two photostimulable phosphor plates in consecutive standardized scannings. Freitas P; Yaedú RY; Rubira-Bullen IR; Escarpinati M; Vieira MC; Schiabel H; Lauris JR Braz Oral Res; 2006; 20(3):207-13. PubMed ID: 17119702 [TBL] [Abstract][Full Text] [Related]
13. Impact of ambient lighting intensity and duration on the signal-to-noise ratio of images from photostimulable phosphor plates processed using DenOptix and ScanX systems. Ramamurthy R; Canning CF; Scheetz JP; Farman AG Dentomaxillofac Radiol; 2004 Sep; 33(5):307-11. PubMed ID: 15585807 [TBL] [Abstract][Full Text] [Related]
14. Effect of various digital processing algorithms on the measurement accuracy of endodontic file length. Kal BI; Baksi BG; Dündar N; Sen BH Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2007 Feb; 103(2):280-4. PubMed ID: 17234548 [TBL] [Abstract][Full Text] [Related]
15. Alternative erasing times of the DenOptix system plate: performance on the detection of proximal caries. Melo DP; Pontual AA; Almeida SM; Campos PF; Tosoni GM Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2009 Jan; 107(1):122-6. PubMed ID: 18656395 [TBL] [Abstract][Full Text] [Related]
16. Quality of film-based and digital panoramic radiography. Molander B; Gröndahl HG; Ekestubbe A Dentomaxillofac Radiol; 2004 Jan; 33(1):32-6. PubMed ID: 15140820 [TBL] [Abstract][Full Text] [Related]
17. Comparison of linear measurements made from storage phosphor and dental radiographs. Conover GL; Hildebolt CF; Yokoyama-Crothers N Dentomaxillofac Radiol; 1996 Nov; 25(5):268-73. PubMed ID: 9161181 [TBL] [Abstract][Full Text] [Related]
18. Effect of delayed scanning on imaging and on the diagnostic accuracy of vertical root fractures in two photostimulable phosphor plates digital systems. Nascimento HA; Visconti MA; Ferreira LM; Suarez MA; Haiter Neto F; Freitas DQ Int Endod J; 2016 Oct; 49(10):973-9. PubMed ID: 26354080 [TBL] [Abstract][Full Text] [Related]
19. Comparison of complementary metal oxide semiconductor and charge-coupled device intraoral X-ray detectors using subjective image quality. Kitagawa H; Scheetz JP; Farman AG Dentomaxillofac Radiol; 2003 Nov; 32(6):408-11. PubMed ID: 15070845 [TBL] [Abstract][Full Text] [Related]
20. Quality of digital pre-implant tomography: comparison of film-screen images with storage phosphor images at normal and low dose. Ekestubbe A; Gröndahl HG; Molander B Dentomaxillofac Radiol; 2003 Sep; 32(5):322-6. PubMed ID: 14709608 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]