BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

248 related articles for article (PubMed ID: 17054885)

  • 1. Bending stiffness and pull-out strength of tapered, variable pitch screws, and 6.5-mm cancellous screws in acute Jones fractures.
    Sides SD; Fetter NL; Glisson R; Nunley JA
    Foot Ankle Int; 2006 Oct; 27(10):821-5. PubMed ID: 17054885
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Jones fracture fixation: a biomechanical comparison of partially threaded screws versus tapered variable pitch screws.
    Orr JD; Glisson RR; Nunley JA
    Am J Sports Med; 2012 Mar; 40(3):691-8. PubMed ID: 22227846
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Biomechanical Comparison of Intramedullary Screw Versus Low-Profile Plate Fixation of a Jones Fracture.
    Huh J; Glisson RR; Matsumoto T; Easley ME
    Foot Ankle Int; 2016 Apr; 37(4):411-8. PubMed ID: 26637274
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intramedullary screw fixation of Jones fractures.
    Kelly IP; Glisson RR; Fink C; Easley ME; Nunley JA
    Foot Ankle Int; 2001 Jul; 22(7):585-9. PubMed ID: 11503985
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Torque resistance after fixation of Jones fractures with intramedullary screws.
    Horst F; Gilbert BJ; Glisson RR; Nunley JA
    Foot Ankle Int; 2004 Dec; 25(12):914-9. PubMed ID: 15680106
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A Biomechanical Comparison of Fifth Metatarsal Jones Fracture Fixation Methods.
    Duplantier NL; Mitchell RJ; Zambrano S; Stone AC; Delgado DA; Lambert BS; Moreno MR; Harris JD; McCulloch PC; Lintner DM; Varner KE
    Am J Sports Med; 2018 Apr; 46(5):1220-1227. PubMed ID: 29466679
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biomechanical Analysis of Conventional Partially Threaded Screws Versus Headless Compression Screws in Proximal Fifth Metatarsal (Jones) Fracture Fixation.
    Lam K; Bui R; Morris R; Panchbhavi V
    Foot Ankle Spec; 2021 Dec; 14(6):509-514. PubMed ID: 32506962
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A new option for intramedullary fixation of Jones fractures: the Charlotte Carolina Jones Fracture System.
    Nunley JA; Glisson RR
    Foot Ankle Int; 2008 Dec; 29(12):1216-21. PubMed ID: 19138486
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biomechanical Comparison of Fully Threaded Solid Cortical Versus Partially Threaded Cannulated Cancellous Screw Fixation for Lisfranc Injuries.
    Rozell JC; Chin M; Donegan DJ; Hast MW
    Orthopedics; 2018 Mar; 41(2):e222-e227. PubMed ID: 29309714
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intramedullary screw fixation of proximal fifth metatarsal fractures: a biomechanical study.
    Shah SN; Knoblich GO; Lindsey DP; Kreshak J; Yerby SA; Chou LB
    Foot Ankle Int; 2001 Jul; 22(7):581-4. PubMed ID: 11503984
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Intramedullary screw fixation of Jones fractures: a biomechanical study.
    Pietropaoli MP; Wnorowski DC; Werner FW; Fortino MD
    Foot Ankle Int; 1999 Sep; 20(9):560-3. PubMed ID: 10509682
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biomechanical comparison of a fully threaded, variable pitch screw and a partially threaded lag screw for internal fixation of Type II dens fractures.
    Magee W; Hettwer W; Badra M; Bay B; Hart R
    Spine (Phila Pa 1976); 2007 Aug; 32(17):E475-9. PubMed ID: 17762280
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fixation strength of anteriorly inserted headless screws for talar neck fractures.
    Capelle JH; Couch CG; Wells KM; Morris RP; Buford WL; Merriman DJ; Panchbhavi VK
    Foot Ankle Int; 2013 Jul; 34(7):1012-6. PubMed ID: 23456083
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Screw fixation diameter for fifth metatarsal jones fracture: a cadaveric study.
    Scott RT; Hyer CF; DeMill SL
    J Foot Ankle Surg; 2015; 54(2):227-9. PubMed ID: 25624041
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Mechanical Comparison of Headless Screw Fixation and Locking Plate Fixation for Talar Neck Fractures.
    Karakasli A; Hapa O; Erduran M; Dincer C; Cecen B; Havitcioglu H
    J Foot Ankle Surg; 2015; 54(5):905-9. PubMed ID: 25998471
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A biomechanical comparison of equine third metacarpal condylar bone fragment compression and screw pushout strength between headless tapered variable pitch and AO cortical bone screws.
    Galuppo LD; Stover SM; Jensen DG
    Vet Surg; 2002; 31(3):201-10. PubMed ID: 11994847
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of Two Types of Intramedullary Jones Fracture Fixation in a Cyclic and Ultimate Load Model.
    Willegger M; Benca E; Hirtler L; Kasparek MF; Bauer G; Zandieh S; Windhager R; Schuh R
    J Orthop Res; 2020 Apr; 38(4):911-917. PubMed ID: 31743452
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Headless compression screw fixation of jones fractures: an outcomes study in Japanese athletes.
    Nagao M; Saita Y; Kameda S; Seto H; Sadatsuki R; Takazawa Y; Yoshimura M; Aoba Y; Ikeda H; Kaneko K; Nozawa M; Kim SG
    Am J Sports Med; 2012 Nov; 40(11):2578-82. PubMed ID: 22989416
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Torsional stiffness after subtalar arthrodesis using second generation headless compression screws: Biomechanical comparison of 2-screw and 3-screw fixation.
    Riedl M; Glisson RR; Matsumoto T; Hofstaetter SG; Easley ME
    Clin Biomech (Bristol, Avon); 2017 Jun; 45():32-37. PubMed ID: 28458187
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A biomechanical comparison of headless tapered variable pitch and AO cortical bone screws for fixation of a simulated lateral condylar fracture in equine third metacarpal bones.
    Galuppo LD; Stover SM; Jensen DG; Willits NH
    Vet Surg; 2001; 30(4):332-40. PubMed ID: 11443594
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.