These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 17058590)

  • 1. Comparison of skin dose between conventional radiotherapy and IMRT.
    Price S; Williams M; Butson M; Metcalfe P
    Australas Phys Eng Sci Med; 2006 Sep; 29(3):272-7. PubMed ID: 17058590
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Surface buildup dose dependence on photon field delivery technique for IMRT.
    Yokoyama S; Roberson PL; Litzenberg DW; Moran JM; Fraass BA
    J Appl Clin Med Phys; 2004; 5(2):71-81. PubMed ID: 15738914
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Matchline dosimetry in step and shoot IMRT fields: a film study.
    Tangboonduangjit P; Metcalfe P; Butson M; Quach KY; Rosenfeld A
    Phys Med Biol; 2004 Sep; 49(17):N287-92. PubMed ID: 15470934
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Experimental determination of peripheral doses for different IMRT techniques delivered by a Siemens linear accelerator.
    Wiezorek T; Voigt A; Metzger N; Georg D; Schwedas M; Salz H; Wendt TG
    Strahlenther Onkol; 2008 Feb; 184(2):73-9. PubMed ID: 18259698
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of build-up dose between Elekta and Varian linear accelerators for high-energy photon beams using radiochromic film and clinical implications for IMRT head and neck treatments.
    Paelinck L; De Wagter C; Van Esch A; Duthoy W; Depuydt T; De Neve W
    Phys Med Biol; 2005 Feb; 50(3):413-28. PubMed ID: 15773720
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A virtual photon source model of an Elekta linear accelerator with integrated mini MLC for Monte Carlo based IMRT dose calculation.
    Sikora M; Dohm O; Alber M
    Phys Med Biol; 2007 Aug; 52(15):4449-63. PubMed ID: 17634643
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Verification of a rounded leaf-end MLC model used in a radiotherapy treatment planning system.
    Williams MJ; Metcalfe P
    Phys Med Biol; 2006 Feb; 51(4):N65-78. PubMed ID: 16467576
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Investigation of secondary neutron dose for 18 MV dynamic MLC IMRT delivery.
    Howell RM; Ferenci MS; Hertel NE; Fullerton GD
    Med Phys; 2005 Mar; 32(3):786-93. PubMed ID: 15839351
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Measurement of superficial dose from a static tomotherapy beam.
    Smith KS; Gibbons JP; Gerbi BJ; Hogstrom KR
    Med Phys; 2008 Feb; 35(2):769-74. PubMed ID: 18383699
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A method for photon beam Monte Carlo multileaf collimator particle transport.
    Siebers JV; Keall PJ; Kim JO; Mohan R
    Phys Med Biol; 2002 Sep; 47(17):3225-49. PubMed ID: 12361220
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Lateral loss and dose discrepancies of multileaf collimator segments in intensity modulated radiation therapy.
    Cheng CW; Das IJ; Huq MS
    Med Phys; 2003 Nov; 30(11):2959-68. PubMed ID: 14655943
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Surface and build-up region dosimetry for obliquely incident intensity modulated radiotherapy 6 MV x rays.
    Dogan N; Glasgow GP
    Med Phys; 2003 Dec; 30(12):3091-6. PubMed ID: 14713075
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Verification of inverse planning and treatment delivery for segmental IMRT.
    Bedford JL; Childs PJ; Warrington AP
    J Appl Clin Med Phys; 2004; 5(2):1-17. PubMed ID: 15738908
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Automatic feathering of split fields for step-and-shoot intensity modulated radiation therapy.
    Dogan N; Leybovich LB; Sethi A; Emami B
    Phys Med Biol; 2003 May; 48(9):1133-40. PubMed ID: 12765327
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ionization chamber dosimetry of small photon fields: a Monte Carlo study on stopping-power ratios for radiosurgery and IMRT beams.
    Sánchez-Doblado F; Andreo P; Capote R; Leal A; Perucha M; Arráns R; Núñez L; Mainegra E; Lagares JI; Carrasco E
    Phys Med Biol; 2003 Jul; 48(14):2081-99. PubMed ID: 12894972
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Variations in energy spectra and water-to-material stopping-power ratios in three-dimensional conformal and intensity-modulated photon fields.
    Jang SY; Liu HH; Mohan R; Siebers JV
    Med Phys; 2007 Apr; 34(4):1388-97. PubMed ID: 17500470
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Experimental verification of a Monte Carlo-based MLC simulation model for IMRT dose calculation.
    Tyagi N; Moran JM; Litzenberg DW; Bielajew AF; Fraass BA; Chetty IJ
    Med Phys; 2007 Feb; 34(2):651-63. PubMed ID: 17388183
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Uncertainties in IMRT dosimetry.
    Li JS; Lin T; Chen L; Price RA; Ma CM
    Med Phys; 2010 Jun; 37(6):2491-500. PubMed ID: 20632560
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improving delivery of segments with small MU in step-and-shoot IMRT.
    Kuperman VY; Lam WC
    Med Phys; 2006 Apr; 33(4):1067-73. PubMed ID: 16696483
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Optimizing the MLC model parameters for IMRT in the RayStation treatment planning system.
    Chen S; Yi BY; Yang X; Xu H; Prado KL; D'Souza WD
    J Appl Clin Med Phys; 2015 Sep; 16(5):322–332. PubMed ID: 26699315
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.